AtmelメーカーCAMELIACOL 2.5Mの使用説明書/サービス説明書
ページ先へ移動 of 12
CAMELIACOL 2.5M 2.5 MEGAPIXEL COLOR DIGITAL CAMERA User guide V 1.1 July 2000 Phone +33 (0) 1 69 33 00 00 - Fax +33 (0) 1 69 33 03 21 1 / 12 www.atmel-grenoble.
CAMELIACOL 2.5M user guide 2 / 12 1. IMA GING SYSTEM DESCRIPTION 3 2. CAMELIA COLOR 2.5 M CAMERA 4 2.1 CCD 4 2.2 Timing 4 2.3 Anti-blooming by clocking 6 2.4 Electrical interfaces : 6 2.4.1 Power supply : 6 2.4.2 digital I/O 6 2.4.3 RS232 interface 7 2.
CAMELIACOL 2.5M user guide 3 / 12 1. IMAGING SYSTEM DESCRIPTION ♦ CAMELIA camera is powered by a +24V power supply. ♦ CAMELIA camera is configured through the serial port of the computer. ♦ CAMELIA camera sends digital video to the FGT frame grabber.
CAMELIACOL 2.5M user guide 4 / 12 2. CAMELIA COLOR 2.5M CAMERA 2.1 CCD ♦ image format : 35.9mm(V) x 26.5mm(H) ♦ 1840(V) x 1360(H) active pixels ♦ readout register along the small side of the image area. (vertical image) ♦ pixel geometries : ◊ 19.
CAMELIACOL 2.5M user guide 5 / 12 Timing diagram (for continuous operation) : Timing diagram (for operation with ‘’external trigger’’) : Timing diagram (for operation with ‘’integration time control’’) : LEN FEN video lines 2 3 1 1838 1839 1840 1360 pixels INT.
CAMELIACOL 2.5M user guide 6 / 12 2.3 A NTI - BLOOMING BY CLOCKING Anti-blooming can be activated or inhibited (see 2.5.3) : ♦ anti-blooming OFF : this position is recommended if anti-blooming is not required for the application. ♦ anti-blooming ON : anti-blooming operation reduces the pixel saturation charge.
CAMELIACOL 2.5M user guide 7 / 12 2.4.3 RS232 INTERFACE Camera configuration is set by RS232 interface. The following features are available : Function RS232 configuration Comment Timing mode 3 modes .
CAMELIACOL 2.5M user guide 8 / 12 2.5 E LECTRO - OPTICAL PERFORMANCE ♦ Conditions : ◊ frame integration time : 40ms ◊ camera operating free air temperature : 25°C ♦ Performance : Parameter Sy.
CAMELIACOL 2.5M user guide 9 / 12 Note : µJ/cm 2 measured on the CCD chip. Including BG38 2mm. 400 500 600 700 0 2000 4000 6000 8000 10000 Wavelength (n m ) Responsivity (ADU/µV/cm²) Red Green Blue Spectral respo nsivi ty C AMELIA COLOR 2.
CAMELIACOL 2.5M user guide 10 / 12 2.6 G EOMETRICAL SPECIFICATIONS 112.0 mm 110.5 mm REAR PANEL DATA & SYNC TH 31CA179M SN: Made in France RS 232 POWER ø 66 . 0 mm 64.0 mm 6.0 mm 2 X ø 2 . 0 mm 4 X M3 64.0 mm FRONT PANEL 74.0 mm 144.5 mm 114.0 mm 2X 1/4_20 UNC 2B 25.
CAMELIACOL 2.5M user guide 11 / 12 2.7 E NVIRONMENTAL REQUIREMENTS ♦ operating temperature : 0°C / +50°C ♦ storage temperature : -20°C / 70°C ♦ operating humidity : < 80% at +35°C ♦ vibration : 2g sinusoidal, from 10Hz to 100Hz. 3. CONNECTORS AND CABLES 3.
CAMELIACOL 2.5M user guide 12 / 12 3.2 ’P OWER SUPPLY ’’ CABLE ♦ On power supply side : ◊ SUBD9 male. Pin out : Pin Number Signal 1 +24V 2 +24V 3 NC 4 NC 5 NC 6 GROUND 7 GROUND 8 NC 9 NC ◊ note : NC : not connected.
デバイスAtmel CAMELIACOL 2.5Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Atmel CAMELIACOL 2.5Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAtmel CAMELIACOL 2.5Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Atmel CAMELIACOL 2.5Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Atmel CAMELIACOL 2.5Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Atmel CAMELIACOL 2.5Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAtmel CAMELIACOL 2.5Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Atmel CAMELIACOL 2.5Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAtmel CAMELIACOL 2.5Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。