PlantronicsメーカーR-410Aの使用説明書/サービス説明書
ページ先へ移動 of 26
R-410A This system uses M00036-V00.
Installation & service manual IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently .
Installation & service manual CONTENTS Safety considerations 1 Accessories 2 Installation recommendations (indoor unit) 3 Installation recommendations (outdoor unit) 4 Electrical installation 5 Wi.
This manual is a guide for properly installing the Williamson-Thermoflo Wall-mounted split air conditioner . Improper installation can result in unsafe and dangerous conditions that will void the factory warranty .
The following accessories are supplied with the air conditioner . • The quantities are indicated in parenthesi s. Installation plate (1) Remote control (1) “AAA” batteries for remote control (2).
1. Before fixing the installation plate to a wall, you must determine the position of the 2 3 / 4 in (70 mm) hole through which the conduit, piping and drain hose pass to connect the indoor unit to the outdoor unit. The piping and conduit can be con- nected from the: Rear , Right or Left side of indoor unit.
Attach the outdoor unit with 4 anchor bolts and nuts (not supplied) positioned as per dimensions A, B. 9SRAO-HE Caution: The outdoor unit should not be exposed to strong winds or where it is very dusty . - T ake your neighbors into consideration so that they will not be disturbed by air blowing into their window or by noise.
1. The air conditioner shall be installed by a qualified technician in accordance with national and local electrical codes. 2. A disconnect switch shall be installed near the outdoor unit for easy disconnect of power to the air conditioner .
3 2 1 T erminal block of indoor unit 3 2 1 L1 N T erminal block of outdoor unit Power supply , 1 phase, 60 Hz INDOOR UNIT OUTDOOR UNIT Installation & service manual _6 WIRING SYSTEM DIAGRAMS Groun.
Installation & service manual _7 WIRING SYSTEM DIAGRAMS 3 2 1 T erminal block of indoor unit 3 2 1 L1 L2 T erminal block of outdoor unit Power supply , 1 phase, 60 Hz INDOOR UNIT OUTDOOR UNIT Grou.
1. The indoor unit is powered from the outdoor unit. A sufficient length of conduit and wiring shall be used from the outdoor unit to the indoor unit. 2. T o access the terminal block inside the indoor unit, remove the screw on the cover plate. (See Fig.
When connecting the refrigerant tubing - Keep all tubing runs as short as possible. - Use the flare method for connecting tubing. - Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.
Installation & service manual _10 REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN INST ALLING UNIT General Information Systems using R-410A refrigerant run at a pressure of approximately 1.6 times that of similar systems using R-22 and the energy efficiency is comparable.
Installation & service manual _11 TIGHTENING REFRIGERANT PIPING CONNECTIONS Caution: Remove the protection caps on the pipes and connect the assembly piping to each connector . First, tighten the nuts manually and then with a wrench by applying the tightening torque shown below .
Installation & service manual _12 SYSTEM EV ACUA TION Condensing unit liquid and suction valves are closed to contain the charge within the unit. The unit is shipped with the valve stems closed and caps installed. Do not open the valves until the system is evacuated.
Installation & service manual _13 ADDITIONAL CHARGE AND DIST ANCE Refrigerant suitable for a piping length of 20 ft (6 m) is charged in the outdoor unit at the factory . When the pipe is longer than 20 ft (6 m), additional charging is necessary . This operation can only be performed by a qualified refrigeration specialist.
Installation & service manual _14 GAS LEAK CHECK Check that no gas escapes from the connections by using a leak detector or soapy water . A and B are the liquid and suction valves of the outdoor unit. C and D are the extremities of the indoor unit flared connections.
Installation & service manual _15 CHECKING AND TESTING OPERA TIONS Perform the operation test after completing the gas leak check of the flare nut connections and the electrical connections. 1. T o begin the test, turn on the power . 2. Press the auxiliary control button in the indoor unit or use the remote control to start the unit.
Installation & service manual _16 TECHNICAL SPECIFICA TIONS SPECIFICA TIONS *Note: Design and specifications are subject to change without notice for product improvement.
In A B C D E F G H I Models: 9SRA-HE | 12SRA-HE | 15SRA-HE | 18SRA-HE | 24SRA-HE Indoor unit Outdoor unit A F B D E H I G C Installation & service manual _17 OUTLINE AND DIMENSIONS 9SRA-HE 10 7/8 .
Installation & service manual _18 P ARTS DIAGRAM (INDOOR UNIT) INSIDE UNIT 9SRAI-HE 12SRAI-HE 15SRAI-HE 18SRAI-HE 24SRAI-HE.
REF . NO DESCRIPTION QTY 9SRAI-HE 12SRAI-HE 15SRAI-HE 18SRAI-HE 24SRAI-HE 1 Faceplate (including display glass) 1 P00843 P00843 P00844 P00844 P00845 2 Lamp board holder 1 P00846 P00846 P00864 P00864 P.
Installation & service manual _20 P ARTS DIAGRAM (OUTDOOR UNIT) OUTSIDE UNIT 9SRAO-HE 12SRAO-HE 15SRAO-HE 18SRAO-HE 24SRAO-HE.
Installation & service manual _21 P ARTS LIST (OUTSIDE UNIT) REF . NO DESCRIPTION QTY 9SRAO-HE 12SRAO-HE 15SRAO-HE 18SRAO-HE 24SRAO-HE 1 Cabinet | Front L | Painted (including fan cover) 1 P00730 .
Installation & service manual NOTE.
8201 W . Calumet Road, Milwaukee, WI 53223 USA www.williamson-ther moflo.com.
デバイスPlantronics R-410Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Plantronics R-410Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPlantronics R-410Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Plantronics R-410Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Plantronics R-410Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Plantronics R-410Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPlantronics R-410Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Plantronics R-410Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPlantronics R-410Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。