Using the Shure® MX392 Push to Talk Microphone with Vortex® Devices Application Note Polycom Installed Voice Business Group September 2004 Rev. B.
Table of Contents TABLE OF CONTENTS .............................................................................................................. ........... 2 SHURE MX3 92 BASI CS .....................................................................
S HURE ® MX392 B ASICS The Shure MX392 is a surface-mount, electret microphone that includes a programmable membrane on/off switch that can be controlled externally via logic input / output terminals.
Switch Behavior User Action Required / LED Behavior DIP Switch Settings Push to Mute, Release to Talk (As Shipped) Press and hold switch to temporarily mute microphone; release switch to unmute.
Here is a drawing showing the functionality that is assigned to each DIP Switch: 5.
L OGIC P ORT The Logic Input port is a female DB-25 connector where pins 1-24 can be programmed to execute commands via the Logic Input page. Pin 25 is the ground pin and it can sink up to 500 mA of current. The Logic Output port is a female DB-25 connector where pins 1-20 can be programmed.
P HYSICAL C ONNECTIONS AND G ROUNDING In order to connect the microphone to the Vortex Device, first connect the audio portion of the microphone to the Vortex Device: Connect the Positi ve conductor (Red) to the Positive terminal, the Negative conductor (Black) to the Negative ter minal, and the Ground wire (gray) to the Ground terminal.
T OGGLE O PERATION (P USH TO T ALK ) Let's say that you want MX392 to be muted by default. If someone pushes the membrane switch, you want the microphone to stay unmuted until the user presses the switch to mute the microphone. You also want the LED to illuminate when the microphone is unmuted.
Now, right click in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O FF . Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute Input 1. Now, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N .
Make sure that the physical wiring works by pressing the membrane switch. You should see the LED above the pin assignment lit in green: Repeat the above process for each MX392 microphone that you want to connect to the Vortex Device. L OGIC O UTPUT Go to the Logic Output page of Conference Com poser.
Next, right click in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O FF . Now, whenever the microphone is unmuted (Mute = False), the LED will illuminate on the MX392. Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N .
Make sure the LED works as designed. If you press the membrane switch, you should see the LED above the pin illuminate in Conference Composer as well as on the MX392.
T OGGLE O PERATION (P USH TO M UTE ) Let's say that you want MX392 to be unmuted by default. If someone pushes the membrane switch, you want the microphone to stay muted until the user presses the switch to unmute the microphone. You also want the LED to illuminate when the microphone is unmuted and not illuminate when the microphone is muted.
Now, right click in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, whenever the switch goes Active Low (0V DC), the Vortex Device will mute Input 1. Now, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O FF .
Repeat the above process for each MX392 microphone that you want to connect to the Vortex Device. L OGIC O UTPUT Go to the Logic Output page of Conference Com poser. If the LED IN wire is connected to Logic Output pin 1, then you need to assign Pin 1 by left-c licking the desired pin in the DB-25 graphic.
Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, whenever the microphone is muted (Mute = True), the LED will not illuminate on the MX392. Here is what the screen should look like when you are finished: Make sure the LED works as designed.
When the membrane switch is pushed again, the EF Device toggles the state from unmuted to muted. Now, the LED should not be illuminated since the input from the MX392 is now muted.
M ACROS Go to the M ACROS page of Conference Composer. To make things easy, label Macro 0 as MUTE ON and label Macro 1 as MUTE OFF. Then, for each microphone that is physically connected to the Vortex, add commands to Macro 0 that mute the microphones and add commands to Macro 1 that unmute the microphones.
In order for one microphone to mute all microphones, we need to be able to mute and unmute the microphones on all units regardless of whether a microphone is muted from the Vortex EF2280 or the EF2241. To accomplish this, we will use the BROADA command to send MUTEI commands from one unit to the other unit.
Repeat that same process for Inputs 2-4 of the Vortex EF2241. The, perform the same procedure to unmute Inputs 1-4 on the Vortex EF2241. Remember that there is a colon after the BROADA command.
Follow the same procedure for muting the Inputs 1-8 on the Vortex EF2280 from the EF2241. Here is what the Macros page for the Vortex EF2241 should look like when you are finished: L OGIC I NPUT Go to the Logic Input page of Conference Composer.
Now, place the cursor in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , M ACRO , 0 ("MUTE ON"). Now, whenever the switch goes Active Low (0V DC), the Vortex Device will execute Macro 0. Now, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , M ACRO , 1 "(MUTE OFF").
Repeat the process for each microphone that is connected to the Logic Input port. If you are successful, you should see this on the screen (the screenshot is from a Vortex EF2241): Make sure that the physical wiring works by pressing the membrane switch.
Next, right click in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O FF . Now, whenever the microphone is unmuted (Mute = False), the LED will illuminate on the MX392. Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N .
Make sure the LED works as designed. If you press the membrane switch, you should see the LED above the pins illuminate in Conference Composer as well as on every MX392.
L OGIC I NPUT Go to the Logic Input page of Conference Composer. If the SWITCH OUT wire is connected to Logic Input pin 1, then you need to assign Pin 1 by left-clicking the desired pin in the DB-25 graphic and selecting the pink color (The pink color means that the pin is not grouped to other pins).
Now, right click in the H ELD C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O FF . Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute Input 1. If you are successful, you should see this on the screen: Make sure that the physical wiring works by pressing and holding the membrane switch.
L OGIC O UTPUT Go to the Logic Output page of Conference Com poser. If the LED IN wire is connected to Logic Output pin 1, then you need to assign Pin 1 by left-c licking the desired pin in the DB-25 graphic. The pin will turn color from gray to pink.
Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, whenever the microphone is muted (Mute = True), the LED will not illuminate on the MX392. Here is what the screen should look like when you are finished: Make sure the LED works as designed.
When the membrane switch is pushed again, the EF Device toggles the state from unmuted to muted. Now, the LED should not be illuminated since the input from the MX392 is now muted.
L OGIC I NPUT Go to the Logic Input page of Conference Composer. If the SWITCH OUT wire is connected to Logic Input pin 1, then you need to assign Pin 1 by left-clicking the desired pin in the DB-25 graphic and selecting the pink color (The pink color means that the pin is not grouped to other pins).
Now, right click in the H ELD C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, as long as the switch is Active Low (0V DC), the Vortex Device will mute Input 1. If you are successful, you should see this on the screen: Make sure that the physical wiring works by pressing and holding the membrane switch.
L OGIC O UTPUT Go to the Logic Output page of Conference Com poser. If the LED IN wire is connected to Logic Output pin 1, then you need to assign Pin 1 by left-c licking the desired pin in the DB-25 graphic. The pin will turn color from gray to pink.
Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, whenever the microphone is muted (Mute = True), the LED will not illuminate on the MX392. Here is what the screen should look like when you are finished: Make sure the LED works as designed.
When the membrane switch is pushed again, the Vortex Device toggles the state from unmuted to muted. Now, the LED should not be illuminated since the input from the MX392 is now muted.
o to the M ACROS G an page of Conference Composer. To make things easy, label Macro 0 as MUTE ON acro 1 d label M as MUTE OFF. Then, for each microphone that is physically connected to the Vortex, add commands to Macro 0 that mute the microphones and add commands to Macro 1 that unmute the microphones.
microphones on all units regardless of whether a microphone is muted from the Vortex EF2280 or the Vortex EF2241. To accomplish this, we will use the BROADA command to send MUTEI commands from one unit to the other unit. The BROADA command broadcasts any comman is after the colon.
Follow the same procedure for muting the Inputs 1-8 on the Vortex EF2280 from the EF2241. Here is what the Macros page for the Vortex EF2241 should look like when you are finished: 38.
L OGIC I NPUT Go to the Logic Input page of Conference Composer. If the SWITCH OUT wire is connected to Logic Input pin 1, then you need to assign Pin 1 by left-clicking the desired pin in the DB-25 graphic and selecting the pink color (The pink color means that the pin is not grouped to other pins).
Now, place the cursor in the A CTIVATED C OMMAND column for Logic Input 1 and select I NSERT , M ACRO , 0 ("MUTE ON"). Now, whenever the switch goes Active Low (0V DC), the Vortex Device will execute Macro 0. Now, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , M ACRO , 1 "(MUTE OFF").
Now, right click in the H ELD C OMMAND column for Logic Input 1 and select I NSERT , M ACRO , 0 "(MUTE ON"). Now, as long as the switch is held down, the Vortex Device will execute Macro 0. Repeat the process for each microphone that is connected to the Logic Input port.
L OGIC O UTPUT Go to the Logic Output page of Conference Com poser. If the LED IN wire is connected to Logic Output pin 1, then you need to assign Pin 1 by left-c licking the desired pin in the DB-25 graphic. The pin will turn color from gray to pink.
Next, right click in the D EACTIVATED C OMMAND column for Logic Input 1 and select I NSERT , I NPUT , 1, M UTE , O N . Now, whenever the microphone is muted (Mute = True), the LED will not illuminate on the MX392. Here is what the screen should look like when you are finished (assuming a Vortex EF2241): Make sure the LED works as designed.
T ECHNICAL S UPPORT For support on the Vortex product line, call toll -free (USA/Canada) 888-248-4143, then select option 1, then option 3. For exclusive Integrator and Consultant focused support (through our PASS program), dial 1.408.474.2048; this number will get you help on video and Vortex products.
デバイスPolycom MX392の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Polycom MX392をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPolycom MX392の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Polycom MX392の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Polycom MX392で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Polycom MX392を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPolycom MX392の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Polycom MX392に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPolycom MX392デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。