FastS tream VT 5700 Fibre Channel to Fibre Channel Virtual T ape Appliance Inst allation and Operation Manual.
A TT O T echnology , Inc. 155 CrossPoint Parkway Amherst, New Y ork 14068 USA www .attotech.com T el (716) 691-1999 Fax (716) 691-9353 Sales support: sls@attotech.com T echnical support: Monday -- Friday , 8am-8pm EST techsupp@attotech.com © 2009 A TTO T echnology , Inc.
Content s 1.0 ATTO FastStream VT Increases Reliability ............. ............... ........... .......... 1 Virtual Tape features Backup and r estore featur es Management and control fea tures 1.1 FastStream VT 5700 Physi cal Attributes ............
6.3 SCSI Enclosure Services (SES) .......... ................ ................. .............. 23 Setting up SES Identifying SES elements Monitoring SES elements Use the Health and Statu s Monitor Use the Manage me nu 7.0 Modify Storage ...... .......
.
1 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 1.0 A TT O FastSt ream VT Increases Reliability A TTO FastS tream™ Virtual T ape appliances are storage solutions that integrate with disk storage and em ulate a tape library for fast restores on demand and error -free backups of critical data.
2.
3 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 1.1 FastS tream VT 5700 Physical Attributes The A TTO FastS tream VT 5700 is a Fibre Channel to Fibre Channel storage appliance which can be seamlessly integrated into a new or existing backup environment.
4 LEDs on the front are: A green power LED A bicolor Ready/Fault LED is lighted green to indicate ready , lighted yellow to a faulted condition, and off indicates not ready . Fibre Channel port s: bicolor LED indicates FC speed. If it is off, speed is 1-Gb.
2.0 Inst al l the FastS tream VT If you have not already completed the instructions on the Getting S tarted manual pa cked with your FastStream VT , use the following instructions to inst all the FastS tream VT . V erifying the contents of the p acking box • The FastStream.
3 Highlight the serial number. 4 Click Next . If a DHCP server is available on your network, an address is assigned automatical ly by the server. Note the assigned addr ess: ____________ _____________.
7 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual 3.0 Ensure Drive Integrity The A TTO FastS tream initialize and verify fea ture discovers and remaps bad sectors on drives, providing reliable media for your RAID groups.
8 Af ter creating RAID group s 1 If you are not already in the Expre ssN AV VTL Manager, type the IP a ddress of your FastStream in a standard browse r. On the splash screen, click Enter Here. In the box provided , type in your user name an d password, and click OK .
9 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 4.0 Configure V i rtual T ape The A TTO FastS tream VT allows configuration of storage in to one or two JBOD, RAID Level 0, 1, 1+0 or 5 V irtual T ape Libraries (VTL).
10 3I n Step 1 on the screen, type in a name for your Virtual Tape Library. Na mes may be u p to 14 characters and may no t contain a ny spaces . 4 Answer the questions in Step 2 based on the needs of your softwar e vendor. • If your storag e is RAID pr ot ected, the FastStream does not reconfigure it.
11 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 6S e l e c t Yes, Assign a Hot Spa re if you want a Hot Spare. 7I n Step 3 , click System Scan to discover the drives available for VTL configuration.
12.
13 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 5.0 Modify System V alues Default values are appropriate for most configurations, but may be modified for your needs using the ExpressNA V VTL manager . Customizing the user name, p assword It is best practice to change the default user name and password.
14 • Time and Date: re fer to Time and Time Zone on page xxii and Date on page xiii of the Appendix. • Fibre Channel da ta rate and connection mode for each Fibre Channel port: refer to FCDataRate on page xv and FCConnMode on page xv of the Appendix.
15 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 6.0 Monitor S torage, Configurations Y ou may monitor storage and determine the performance of drives attached to the FastS tream VT using the ExpressNA V VTL manager. If you have set up at least one Virtual T ape Library (refer to Configure Virtual Tape on page 9.
16 Health and S t atus Monitor p age The Health and S tatus Monitor provides information about RAID group status, FastS tream VT environmental st atus, Ethernet and Fibre Channel interface states, and drive status, including links to diagnostics and more detailed information.
17 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual Configuration Display p age Clicking Details in the Health and Status Monitor page gives you added information abou t each parameter on the Configuration Display page. Y ou may view the details of any p arameter from this page.
18.
19 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual 6.1 Remote System Monitoring Y ou may set up the FastStream to send notifications using Email when certain events occur . Y ou may se t up the FastS tream to send notifications when certain event s occur using the Error Notification page of the ExpressNA V VTL Manager .
20 10 Choose Al l , Critical , Warning, Informational or None for each Email address. 11 When all informatio n is typed in, click Commit . 12 A warning box appea rs. In the war ning box, verify that you want to complete the notific ation procedure including a restar t of the FastStream by selecting Yes .
21 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual 6.2 Drive Diagnostics Y ou may determine the performance of drives attached to the FastS tream using the ExpressNA V VTL Manager . The following instructions assume you have already set up at least one RAID group.
22 Read only drive test The read only test performs a non-destructive scan over the entire surface of each drive to identify bad areas of the disk drives and determine read performance. It may be run while data is p assing through the FastS t ream. Running this test may negatively impact performance.
23 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual 6.3 SCSI Enclosure Services (SES) Drive enclosures may provide a SCSI Enclosure Processor which indicates enclosure health status, drive identification and drive fault.
24 Identifying SES element s The SES Monitor page, found by clicking Details in the Enclosure Status section of the Health and Status Monitor page, list s SES information about specific enclosures (see Exhibit 6.
25 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual Monitoring SES element s Enclosures which provide SES information are listed in the Enclosur e Status section of the Health and Status Monitor (see Exhibit 4 ) and through the Enclosure Serv ic es arrow on the Manage menu.
26 Use the Manage menu 1 If you are not already in the Expre ssN AV VTL Manager, type the IP a ddress of your FastStream in a standard browse r. On the splash screen, click Enter Here. In the box provided , type in your user name an d password, and click OK .
27 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 7.0 Modify S torage Use the ExpressNA V VTL manager to replace a failed drive, add new drives or redesign VTL configurations. The ExpressNA V VTL manager takes you step by step through many procedures which allow you to modify your storage and VTL.
28 Secure dat a through W rite Protection For added security , write protection can be enabled for any tape cartridge with a VTL. When write protection is enabled, existing data on the t ape cartridge cannot be overwritten or erased. The data can be sorted by any field by clicking the label for the field.
29 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 7 When you have compl eted your changes, click Commit. CA UT ION CA UT ION During this procedure , do not power down the host or the A TTO FastS t ream VT until the Health and S tatus Mo nitor p a ge appears.
30 FastS tream operations: addi ng or removing Hot S p ares The A TTO FastS tream VT replaces degraded or faulted drives in a VTL without intervention by you or a host if you set up a pool of Hot S pare drives of dif ferent sizes appropriate for your VTL.
31 A TTO T echnology Inc. FastS tream SC Installation and Operation Manual 8.0 Manage A TT O Devices Y ou may manage other A TTO devices from your current browser using the ExpressNA V VTL Manager .
32.
33 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 9.0 Interface Options The best way to manage, monitor and configure the FastStream VT is to use the ExpressNA V VTL manager , but you may use a terminal emulation program or T elnet.
34 Using the serial port T o connect to a terminal emulation program or T el net to manage the FastS tream VT , use the serial port. 1 Connect a cable from FastStream VT RS-232 serial port or header to the serial (C OM) port on a personal comp uter. 2 Turn on th e FastStre am VT.
35 A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual 10.0 Up date S torage, Firmware Y ou can update the A TT O FastStream VT at any tim e. Refer to www .attotech.com for complete information. Several methods are available to update the A TTO FastS tream firmware and to re-initialize unattached storage.
36 5T h e Diagnostics Menu page appears. From the Select User Process box, select Update the Firmware . 6 Click Next . 7 If you know the name and location of the .ima file, enter it into the text box provided . If you do not know the file name and location, select Browse to navigate to the new firmware.
i A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual Appendix A Glossary Familiarity with the following terms may be useful. Other sources for terms used in storage applications may be found at Te r m Definition Bridge LUN Virtual T ape Appliance LU N for processor functionality .
ii.
iii A TTO T echnology Inc. FastS tream SC Installation and Operation Manual Appendix B Design RAID Group s The A TTO FastS tream VT 5700 provides instant hardware dat a protection and intelligence to existing storage independent of the storage type.
iv RAID Level 0: stripi ng, no redundancy RAID Level 0 (striping) increases performance by simultaneously accessing data across multiple drives by overlapping drive seeks. The process increases data transfer rates. Drives are accessed alternately , as if stacked one on top of the other .
v A TTO T echnology Inc. FastS tream SC Installation and Operation Manual RAID Level 1+0: striping, mirror sp ans two drives RAID Level 1+0 increases data transfer rates while ensuring security by writing the exact same data simultaneously to two or more dif ferent drives.
vi.
vii A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual Appendix C CLI Provides an ASCII-based Interface The command line interface (CLI) uses ASCII commands typed while in CLI mode. CA UT ION CA UT ION Do not use CLI unless you are directed to by an A TTO technician.
viii CLI error messages The following error messages may be returned by the Command line Interface ERROR. Invalid Command. Type 'Help' for command list.
ix A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual ClearEventLog cleareventlog Date set date 03/03/2007 DefaultInterleave 128 set default i nterleave 64 DeleteAllMaps dele.
x IP Address 10 .0.0.1 get ipaddress mp1 IPDHCP enabled set ipdhcp mp1 disabled IPDNSServer set ipdnsserve r 172.15.12.123 IPGateway 0.0.0.0 get ipgateway mp1 IPSubnetMask 255.
xi A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual RGMemberRemove rgmemberremove g1 22 RGPreFetch 0 rgprefetch g1 2 RGRebuild rgrebuild g1 RGResumeConversion rgresumeconve.
xii CLI command explanations Command Line Interface commands are listed alphabetically with explanations of what they are used for , their defaults and synt ax.
xiii A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual Boot Delay Regulates the delay (in seconds) which the unit wa its after st artup before allowing hosts to detect target devices.
xiv DriveT estLi st Specifies d riv es to be run in the next dri v e te st of drives which are not part of a RAID group or which are Hot Spares. The all parameter automati cally choose s eligible drives. The test is no t started until the DriveTest Begin command is given.
xv A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual EventLog When enabled, records vario us system events and errors to the even t lo g. Default: enabled set EventLog [enabled | disabled ] get EventLog EventLog Filter Filters data from specific unit subsystems and levels when event logging is enable d.
xvi FCWWName Reports the Word Wide Name (WWN) of the FC interface. Each FC port has an individual and uni que WW N. The least significant 3 bytes of th e WWN are used as the Ethernet MAC address. The lower nibble of the highest byte designates the port number .
xvii A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual Metri cs Controls the collection of standard data metrics within a product via the command’s Start, Stop and Display parameters.
xviii ReadOnlyPassw ord Specifies a password which allows only read and no writes. It is case sensitive, 0 to 32 characters, and cannot contain spaces. An empty password can be configu red by not specifying one. set ReadOnlyPassword ReadOnlyUsername Specifies the user name which allows only read and no writes.
xix A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual RGDispla y Lists st atus information for a single RAID group, or if All is used, all available RAID groups. RGDisplay < GroupName | All > RGHaltConversion S tops the conversion o n the specified exi sting RAID group.
xx RGW aitTimeout Specifies the maximum time in seconds that the system wait s to d isc over previously-co n fi gured RAID group s attached to the drive.
xxi A TT O T echnology , Inc. FastS tream VT Installa tion and Operatio n Manual SESIdentify T ells the appr opriate SES en closure to identify the specified element(s). ALL i dentifies all disks. RAID GroupName identifies all disks in a RAID Group. If the MemberIndex is also specified, only that d isk is identified.
xxii T apeWriteProtect Controls write protection for a particular virtual tape or two virtual tapes. set T apeWriteProtect [T ape V ol ID | all] [enabled | disabled] get T apeWriteProtect T emperatu re Lists the current internal operating temperature of this unit in degrees Celsius.
xxiii A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual Appendix D S t andards, Compliances The equipment described in this manual generates and uses radio frequency energy .
xxiv The A TTO FastS tream VT complies with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS).
xxv A TTO T echnology Inc. FastS tream VT Installation and Opera tion Manual Appendix E W arranty Manufacturer li mited warranty Manufacturer warrants to the original purchaser of this product that it is free from defect s in material and workmanship as described in the A TTO T echnology website, www .
xxvi.
デバイスAtto technology VT-5700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Atto technology VT-5700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAtto technology VT-5700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Atto technology VT-5700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Atto technology VT-5700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Atto technology VT-5700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAtto technology VT-5700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Atto technology VT-5700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAtto technology VT-5700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。