INSTALLATION MANUAL CTM-MS2 Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.
PBL-110 Projector Mount Page - 2 - Installation Manual.
CTM-MS2 Installation Manual Page - 3 - Table of Contents Warning Statements ............................................................................................................ ............................ - 4 - Parts List ....................
CTM-MS2 Page - 4 - Installation Manual Warning Statements WARNING: THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 160 LBS. IF NOT, THE WALL STRUCTURE MUST BE REINFORCED. PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO.
CTM-MS2 Installation Manual Page - 5 - Parts List NOTE: This wall mount is shipped with all proper ins tallation hardware and components. Make sure that none of these parts are missing an d/or damaged be fore beginning installation. If there are parts missing and/or damaged, please stop the in stallation and contact Premier Mounts (800-368-9700).
CTM-MS2 Page - 6 - Installation Manual M4 x 25 M5 x 20 M5 x 50 M8 x 20 M6 x 30 ( Qty 6) ( Qty 4) ( Qty 6) ( Qty 4) ( Qty 2) M4 x 16 (Qt y 8) ( Qty 8) M5 x 12 M5 x 16 ( Qty 6) M5 x 25 ( Qty 4) M6 x 12 .
CTM-MS2 Installation Manual Page - 7 - Nylon spacers and flat washers actual size NOTE : The nylon spacers may be stacked to achieve proper spacing. 1/ 4 " N yl o n spa c er s 5/16 " Fl at w.
CTM-MS2 Page - 8 - Installation Manual Thread Depth Indicator 1. Insert the thread depth indicator (supplied) throu gh the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it (Figure 1). 2.
CTM-MS2 Installation Manual Page - 9 - Mounting Bracket Installation NOTE : Proper installation procedure by qualified personnel as outlined in the install ation instructions must be adhered to. Failure to do so could result in serious personal injury an d possible damage to the flat panel.
CTM-MS2 Page - 10 - Installation Manual 3. Install the nylon spacers (if needed) to the mounting points on the flat panel (Figure 6). 4. Lay the left and right mounting brackets (stamped arrows facing out) - (Figure 7). Figure 6 Figure 7 5. Match the center of viewing guide with th e centerline you marked in Step 1 (Figure 8).
CTM-MS2 Installation Manual Page - 11 - L C Figure 8 Figure 9 7. The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE : If your plasma uses M8 x 20 Phillip screws. Use th e M8 mounting points (Figure 10).
CTM-MS2 Page - 12 - Installation Manual CTM-MS2 Installation 1. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall (Figure 12). 2. Once found, make a pencil marking on the center of the wood studs (Figure 13).
CTM-MS2 Installation Manual Page - 13 - 4. Level the wall plate with the reference a rrow pointing up to the ceiling (Figure 15). 5. Drill six (6) ¼" pilot holes to the marked wall. 6. Secure the plate using the six (6) 5/16" lag bolts and flat washers (Figure 16).
CTM-MS2 Page - 14 - Installation Manual Installing the Flat Pa nel Display (CTM-MS2) WARNING : AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.
CTM-MS2 Installation Manual Page - 15 - 2. Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30mm Phillips screws found on the bottom of the mounting brackets. Use the foot leveler to adjust your plasma. CAUTION : Do not over tighten the M6 x 30mm screws to the rods (Figure 18).
CTM-MS2 Page 16 Installation Manual Page 3. Tilt the flat panel and secure the two (2) M6 x 12 mm safety knobs to each of the mounting bracke ts (Figure 19).
CTM-MS2 Installation Manual Page 17 Technical Specifications 28.000 (171.2) 1 2 L C 16.000 (406.4) 24.000 (616.97) 8.000 (203.2) 8.000 (203.2) 19.000 (482.6) C L 21.000 (533.4) 12° 2.331 (59.21) 19.000 (482.6) A B C D E H G F G H A. Wall plate B. Mounting brackets C.
CTM-MS2 Page 18 Installation Manual Warranty Limited Lifetime Warranty All Premier Mounts products carry a limit ed lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for imprope r installation that result s in damage to mounts, adapters, display equipment or personal injury.
CTM-MS2 Installation Manual Page 19 Notes Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.
AST-2446/2 Suspensio n Adapter Installation Instructions Page 1 AST-2446/2 INSTALLATION INSTRUCTIONS 1. Separate the upper pipe and lower tube. Install the upper pipe to the ceiling structure using commercial standards and commercially availabl e suitable hardware (Figure 1).
AST-2446/2 Suspensio n Adapter Page 2 Installation Instructions Figure 2 . Figure 3 ..
PSD-S Installation Instructions Page 1 PSD-S INSTALLATION INSTRUCTIONS 1. Separate the upper pipe and the lower tube. 2. Install the upper pipe in the ceiling stru cture using suitable commercial hardware. 3. Screw the lower portion of the PSD-S to th e coupling and secure with the Allen screws.
デバイスPremier Mounts CTM-MS2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Premier Mounts CTM-MS2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPremier Mounts CTM-MS2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Premier Mounts CTM-MS2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Premier Mounts CTM-MS2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Premier Mounts CTM-MS2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPremier Mounts CTM-MS2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Premier Mounts CTM-MS2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPremier Mounts CTM-MS2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。