PrincetonメーカーLS 785の使用説明書/サービス説明書
ページ先へ移動 of 22
Ver. 1.2 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www. piacton.com LS -785 High Throug hput Lens Spectro graph User Manual.
.
iii Table of Contents Chapter 1 -- General ...................................................................................................................................................5 Description ...............................................
iv LS -785 H igh Throughput L ens Spectrograph U ser Ma nual This page intentionally left blank..
5 Chapter 1 -- Gen eral Des cription The Acton LS- 785 i s an 85 mm focal length high th roug hput lens spectrograph specifica lly designed an d optimized for near infrared (NI R) appl ications.
6 LS -785 High Throughpu t Lens Spect rograph User M anual Inside the LS - 785 Focus Adjustment Grating PIXIS CCD Detector Entrance Slit Shutter Collimating Lens X-Y Fiber Adapter Entrance Slit Adjust.
7 Chapter 2 -- Op eration Hardware Installati on Mounting the Detector to the LS-785: Optional adapter f langes are av ailable with this LS - 785 for the follow ing Princeto n I nstrument CCD detecto rs: 1. PIXIS w ith spectroscopy flange and wi thout shutter.
8 LS -785 High Throughpu t Lens Spect rograph User M anual WinSpec Software I nstallation 1. Verify that the de tector (and cont roller) is conne cted to the com put er and that the detecto r is turned on.
Chapter 2 -- Operation 9 Manual Slit Width A djustment The slit width of th e bilateral slit assem bly is adjus table from 0.010 m il lim eters to 3 m illimeters (10 to 3,000 µm ) by a microm eter located on the top of the slit hou sing. The m icr ometer k nob is graduate d in 0.
10 LS -785 High Throughpu t Lens Spect rograph User M anual Focus Adjustment When purchased w ith a Princeton I nst ruments CCD de tector, the LS- 785 is normally focu sed and aligned at the factory and shipped a s an integrat ed system ready to operate.
Chapter 2 -- Operation 11 Grating Assembl y Interchange The LS-785 g rating assembly is initially alig ned at the fac tory and kinem atically m ounted in the instrum ent to enable easy interc hange without requiring realig nment.
12 LS -785 High Throughpu t Lens Spect rograph User M anual 10. Replace and se cure the LS -785 cover. P lace the prev iously rem oved grating assem bly in the storage container and secur e it using the knurled screw. Tighten the two capt ive screws to secure the gra ting assembly in the s torage con tainer and then replace the lid.
Chapter 2 -- Operation 13 Shutter Re pla cement The following instructions apply if the LS - 785 was shipped from the factory w ith an installed external shutter. Be cause a shutter has a finite lifetim e, i t may become necessary to replace a shutter.
14 LS -785 High Throughpu t Lens Spect rograph User M anual X- Y Fiber Adapter The universal XY fiber adapter al lows an op tical fiber which is terminated in a 10m m ferrule, SMA con ne ctor or FC co.
Chapter 2 -- Operation 15 Figure 2- 12 . X-Y Stage Adjus tment 5. Take a full im age while r unning the camera in F ocus mode. 6. Identify a suitable p eak (for example, Neon at 837.6 nm ). 7. Zoom in on the peak into a w indow approxim ately 25 pixe ls x 25 pixels.
16 LS -785 High Throughpu t Lens Spect rograph User M anual This page intentionally left blank..
17 Append ix A – Specifications Outline Drawing.
18 LS -785 High Throughpu t Lens Spect rograph User M anual Relative Wavelengt h Coverage with 12 00 g/mm Grating Laser (nm) Working range (cm-1)* Coverage (cm-1)** 785 120 - 3215 1985 805 120 - 2898 .
19 Append ix B -- Mounting the Detector The following procedures are recom mended for m ounting detectors and t heir associa ted adapters to the LS- 7 85. Refer to the photog r aphs for add itional inform at ion. 1. Determine the det ector to be attac hed to the LS- 785.
20 LS -785 High Throughpu t Lens Spect rograph User M anual P IXIS Tools: 5/32 ” hex wrench 5/16” wrench Procedure: 1. If detector o ther than a PI XIS was previously m ounted t o the LS- 785, re-install th e four #8-32 socket head screws and wa shers us ed in the instrum ent housing to secu re the other adapt er.
Appendix B -- Mounting th e Detector 21 Spec 10 LN w ith Int egrated Shutte r Tools: 9/64” hex wrench 5/32” hex wrench Procedure: 1. Locate the Spec 10 LN detector wit h an internal shutter and its adapter flang e. 2. If another adap ter is mounted to the LS-785, remov e that adapter (an d, in the case of the PI XIS, the adapter and space r).
22 LS -785 High Throughpu t Lens Spect rograph User M anual Spec 10 LN w ithout Sh utter Tools: 9/64” hex wrench fo r remov ing 4 screws with washers .
デバイスPrinceton LS 785の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Princeton LS 785をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPrinceton LS 785の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Princeton LS 785の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Princeton LS 785で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Princeton LS 785を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPrinceton LS 785の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Princeton LS 785に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPrinceton LS 785デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。