Po w e r S c a n ® RF Handheld Bar Code Scanner User’ s Guide.
PSC Inc 959 T err y Street Eugene, Oregon 97402 T elephone: (541) 683-5700 F ax: (541) 345-7140 An Unpublished W ork - All r ights reserved. No pa r t of the contents of this documentation or the procedures described therein may be reproduc ed or tr ansmitted in any form or by an y means without prior wr itten permis sion of PSC Inc.
PSC INC. POWERSCAN ® END USER LICENSE AGREEMENT Notice to End User: The PSC Product y ou have acquired contains embedded Software, wh ich is integral to the product’ s operation . This Software is being provided to y ou under license, subject to the terms and conditions of this Ag reement.
uct, uses the product in any manner other than as established in the Docum entation, or if En d User breaches an y of the pro visio ns of this Agreement.
Standard Warranty PSC warrants to Customer that PSC 's products will be free from defects in materials and workmans hip for a period of two y ears f rom product shipment.
NO TES.
User’ s Guide i T ABLE OF CONTENTS Unpack and Inspect Your Scanner ........................................ ........................................ 1 References ............................................ ....................................... ..
ii PowerScan ® RF Scanner.
User’ s Guide 1 Unpack and Inspect Y our Scanner After unpacking your new scanner , check the contents of the shipping carton to ensure all the items you or dered are included: • PowerScan ® RF handheld scanner • Battery Pack(s) • User ’s Guide (this manual) • Optional Accessories that you order ed.
2 PowerScan ® RF Scanner Installing the Battery Orient the battery as shown in Figure 1, then push it into the scanner until it snaps in place. T o r emove the battery , push in on the release tabs on both sides of the battery’s base and pull it straight out of the scan- ner .
User’ s Guide 3 Ve r i f y i n g Scanner Operation Once a charged battery has been inst alled in the scanner , scan the sam- ple bar codes in the back of this ma nual that correspond to the symbol- ogies your scanner is programmed to r ead. If unsure how to do this, see the section on How to Scan in this manual.
4 PowerScan ® RF Scanner Figure 2 . Connecting/Disconnecting the Interface (I/F) Cable 2. Consult your Host T e rminal manual to determine the r equired communication parameters for th e Host T erminal (e.g., baud rate, parity , etc.) and, if necessary , modify the programmed parameters to be compatible with those requir ements.
User’ s Guide 5 The Base Station’s POWER LED should be illuminated when the unit is properly connected to power . Figure 3. Connecting P ower to the Base Station 5.
6 PowerScan ® RF Scanner The existing Base Station system configuration can be automatically downloaded to the scanner . This automatic download feature is config- urable and can be disabled. See the Systems Manual for more informa- tion about this feature.
User’ s Guide 7 Ve r i f y i n g Scanner-to- Base Station Comm unications Point the linked scanner at a sample bar code from the back pages of this manual, and pull the trigger (see How to Scan for tips on scanning bar codes).
8 PowerScan ® RF Scanner Using the P owerScan RF System This section covers the following topics: • Battery Charging and Maintenance • How to Scan • LED and Beeper Indications Battery Charging and Maintenance Seat the scanner in the Base Station as shown in Figure 4, ensuring that the battery fully engages the stat ion’s metal contacts.
User’ s Guide 9 Rapid flashing indicates that charging is taking place. Rapid char ging occurs when the battery temperature is between 10°C (50°F) and 46°C (1 15°F), and/or voltage of the batt ery is between 2.0 and 3.2V . Charge time is less than 4.
10 PowerScan ® RF Scanner Four Station Charger If you have a Four Station Charger , batteries are inserted for charging as shown in Figure 5. A 90% rapid char ge can be achieved in only two hours when using this optional accessory , half the time than when a Base Station is used for charging.
User’ s Guide 11 How to Scan Figure 6 illustrates some tips to help get the best scanning r esults: 1. The scanner must be pointed at a slight angle to the bar code. Do not hold the scanner perpendicular to the bar code. 2. The laser beam must cross the entir e bar code.
12 PowerScan ® RF Scanner Depth of Field There ar e currently four dif ferent range models for the scanner . Depending upon the model type of yo ur scanner , you’ll need to hold the unit at a given distance from the bar code to achieve optimum scan- ning results.
User’ s Guide 13 Figure 8. Depth of Field (HD) NO TE See the section titled, Definition of a "mil" for more information about reading this chart. Measurements are based on HD models set with the standard 28° scan width (as opposed to the Half Angle setting of 14°).
14 PowerScan ® RF Scanner Figure 9. Depth of Field (LR) NO TE See the section titled, Definition of a "mil" for mor e information about reading this chart. Measurements are based on LR models set with the a 14° scan width (as opposed to the alternate Full Angle set- ting of 28°).
User’ s Guide 15 Figure 10. Depth of Field (XLR) NO TE See the section titled, Definition of a "mil" for more information about reading this chart. Measurements are based on XLR models set with a 10° scan angle width. Specifications are subject to change without notice.
16 PowerScan ® RF Scanner LED and Beeper Indications The Base Station LED indicators and the scanner ’s LEDs and beeper are used to announce system status and perform other useful signals. The tables below list the default function of each of the various indica- tors.
User’ s Guide 17 T able 2. Scanner YELLO W LED Functions T able 3. Scanner BEEPER Functions LED INDICA TION DURA TION COMMENT Laser on indica- tion On Steady The yellow LED illuminates whenev er the laser is on.
18 PowerScan ® RF Scanner Ta b l e 4 . Base Station LED Functions T ransmission Error Beep High, then low , then high, then low . Indicates unsuccessful transmission to the host. Link Beep Low , then medium, then high. Indicates a scanner has been successfully linked to a base station.
User’ s Guide 19 Active Symbologies The active (enabled) bar code symb ologies in the standard factory defaults are: • Code 39 (C39) • Code 128 (C128) • Interleaved 2 of 5 (I 2 of 5) Y our scanner should be pr e-programmed with these standard factory default settings, unless.
20 PowerScan ® RF Scanner Enhanced Scanning for Hard-to-Read Bar Codes Decoded scanners can be programmed to decode extremely poor qual- ity bar codes by activating advanced Quadralogic II™ Decoding. T o select this feature, see the Pr ogramming Guide.
User’ s Guide 21 Laser Cautions The PowerScan RF bar code scanner is certified in the U.S. to conform to the requir ements of DHHS/CDRH 21CFR Subchapter J for Class II laser products (SR and LR) and Class IIIa (XLR) . Class II and IIIa pr oducts are not considered to be hazar dous.
22 PowerScan ® RF Scanner Radio Frequency Interference This device complies with Part 15 of the FCC Rules. Operation is sub- ject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference r eceived, including interference that may cause undesir ed operation.
User’ s Guide 23 Maintenance The scan window will requir e occasional cleaning to remove smudges, dust and other debris. T o ensure op timal performance, clean the Scan W indow using a soft cloth or lens tissue dampened with isopropyl alcohol (or equivalent).
24 PowerScan ® RF Scanner T r oubleshooting T r oubleshoot your RF scanning system by performing the following checks: For the RF system, ensure that... • the battery is charged. See “B attery Charging and Mainte- nance” on page 8. • the battery is properly installe d.
User’ s Guide 25 Sample Bar Codes Use these test bar codes to check the scanner ’s ability to r ead the vari- ous symbologies repr esented. Code 128 Code 39 Interleav ed 2 of 5 Standard 2 of 5 Codabar Code 93 C ode 128 . T e s t COD E 3 9 . T E S T 0123456789 1 2 3 4 5 6 7 8 9 0 A$ 9 9 .
26 PowerScan ® RF Scanner MSI/Plessey UPC-A UPC-A with 2 digit Add-on UPC-A with 5 digit Add-on UPC-E EAN-8 EAN-13 14476925 4 0 00112 23344 0 4 9 0 6 0 9 9 2 0 1 1 1 8 7 6 9 0 0 0 0 0 8 0 2 9 5 1 0 4.
DECLARA TION OF CONFORMITY PSC hereby declares that the Equipment sp ecified below has been tested and found compliant to the following Directives and Standards: Brad W est Vi c e P re s i d e n t Quality and Process Manage- ment PSC, Inc. 959 T e rry Str eet Eugene, OR 97402 U.
www .psc.com Asia Pacific PSC Hong K ong Hong K ong T elephone: [852]-2-584-6210 F ax: [852]-2-521-0291 Australia PSC Asia P acific Pty Ltd. Nor th Ryde, A ustralia T elephone: [61] 0 (2) 9878 8999 F ax: [61] 0 (2) 9878 8688 France PSC S.A.R.L. LES ULIS Cedex, F rance T elephone: [33].
デバイスPSC PowerScan RFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
PSC PowerScan RFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPSC PowerScan RFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。PSC PowerScan RFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。PSC PowerScan RFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
PSC PowerScan RFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPSC PowerScan RFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、PSC PowerScan RFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPSC PowerScan RFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。