Q-Logicメーカー64の使用説明書/サービス説明書
ページ先へ移動 of 244
Simplify D 59043-03 A Page i SANbox2-64 Fibre Channel Switch Inst allation Guide.
Page ii 59043-03 A D SANbox2-64 Fibre Channel Switch Installation Guide © 2000–2003 QLogic Corporation First Printed: May 2002 All Rights Reserved Worldwide. Printed in U. S.A. Information fu rnished in this manual is believed to be accurate and reliab le.
59043-03 A Page iii T able of Content s Section 1 Introduction 1.1 Intended Audience .................................................... ......................................... 1-1 1.2 Related Materials .............................................
Page iv 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D 2.2.2.1 Over T emperature LED (Amber) ....................................................... 2-6 2.2.2.2 Fan Fail LED (Amber) ....................................................
59043-03 A Page v SANbox2-64 Fibre Channel Switch Installation Guide D 4.1.2 Switch Power Requirements ..................................................................... 4-1 4.1.3 Environmental Con ditions ..........................................
Page vi 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D 5.2.4 Output Power LED Is Extingu ished ......................................................... 5-1 1 5.2.5 Power Supply Fault LED is I lluminated ..............................
59043-03 A Page vii SANbox2-64 Fibre Channel Switch Installation Guide D Appendix B Command Line Interface B.1 Logging On to a Switch .................................................................. .................... B-1 B.2 Command Synt ax .....
Page viii 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Zone Command ........................................................... ............................ B-97 Zoneset Command ......................................................
59043-03 A Page ix SANbox2-64 Fibre Channel Switch Installation Guide D Ta b l e s T able Page 2-1 Serial Port Pin Identification .................. ................................................................ ....... 2-11 3-1 Port-to-Port Transmission Combinations .
Page x 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Notes.
59043-03 A 1-1 Section 1 Introduction This manual describes the features and in st allation of the SANbox2-64 Fib re Channel switch, firmware version 3.
1 – Introduction Related Materials 1-2 59043-03 A D 1.2 Related Materials The following manuals and materials are referenced in the text and/or provide additional information. SANbox2-64 Switch Management User ’s Guide , Publication Number 59048-03.
1 – Introduction Safety Notices 59043-03 A 1-3 D 1.3 Safety Notices A Wa r n i n g notice indicates the presence of a hazard that has the potential of causing personal injury . 4-3 , 4-6 , 6-2 , 6-8 , 6-12 , 6-15 , 6-16 , 6-19 A Caution notice indicates the presence of a hazard th at has the potential of causing damage to the equipment.
1 – Introduction Communications Statements 1-4 59043-03 A D 1.6 Communications St atement s The following st atements apply t o this product. The statement s for other product s intended for use with this product appear in their accomp anying manuals.
1 – Introduction Communications Statements 59043-03 A 1-5 D entraîner le brouillage des réceptions radio et télé, ce qui oblige rait le propriétaire ou l'opérateur à prendre les dispositions né cwssaires pour en éliminer les causes. 1.
1 – Introduction Communications Statements 1-6 59043-03 A D 1.6.5 VCCI Class A St atement This is a Class A product based on the standard of the V oluntary Control Council For Interference by Informa tion T echnology Equipment (VCCI). If this equipment is used in a domestic environment, radi o distu rbance may arise.
1 – Introduction Laser Safety Information 59043-03 A 1-7 D 1.7 Laser Safety Information This product may use Class 1 laser optical transceivers to communicate over the fiber optic conductors. The U. S. Depa rtment of Health and Human Services (DHHS) does not consider Class 1 lase rs to be hazardous.
1 – Introduction Accessible Parts 1-8 59043-03 A D 1.9 Accessible Part s The Field Replaceable Units (FRUs) in the SANbox2-64 switch are th e following: Small Form-Factor Pluggable (SFP) op tica.
1 – Introduction General Public License 59043-03 A 1-9 D 1.12 General Public License QLogic Fibre Channel switches are power ed by the Linux operating system. A machine-readable copy of th e Linux source code is avai lable upon written request to the following address.
1 – Introduction General Public License 1-10 59043-03 A D We protect you r rights with two steps: (1) copyr ight the software, and (2) of fer you this license which gives you legal permission to co py , distribute and/or modify the software.
1 – Introduction General Public License 59043-03 A 1-1 1 D modifications or work under the terms of Section 1 above, provided that you also meet all of these conditions: a. Y ou must cause the modifie d files to carry prominent notices stating that you changed the files a nd the date of any change.
1 – Introduction General Public License 1-12 59043-03 A D b. Accompany it with a written o ffer , valid for at least three ye ars, to give any third party , for a charge no more than your cost of ph.
1 – Introduction General Public License 59043-03 A 1-13 D rights granted he rein. Y ou are not responsible for enf orcing compliance by third parties to this License.
1 – Introduction General Public License 1-14 59043-03 A D License, you may choose any version ever published by the Free Sof t ware Foundation. 12. If you wish to incorporate pa rts of the Program into other free programs whose distribution conditions are dif ferent, write to the author to ask for permission.
1 – Introduction General Public License 59043-03 A 1-15 D one line to give the pro gram's name and an idea of what it does. Copyright (C) yyyy name of author This program is free sof tware; you.
1 – Introduction Technical Support 1-16 59043-03 A D 1.13 T echnical Support Customers should cont act their authorized maintenance provider for technical support of their QLogic switch product s. QLogic-direct customers may conta ct QLogic T echnical Support; others will be redire cted to their authorized maintenance provider .
59043-03 A 2-1 Section 2 General Description This section describes the features and capabilities of the SANbox2-64 Fibre Channel switch. The following top ics are described: Chassis hardware .
2 – General Descrip tion Chassis Hardware 2-2 59043-03 A D 2.1 Chassis Hardware The SANbox2-64 switch is set of up to eight 8-p ort I/O blades. Each I/O blade is interconnected with all other I/O blades throu gh the backplane which is supported by four cross-connect ASICs.
2 – General Description Chassis Hardware 59043-03 A 2-3 D numbered 0–63 from top to bottom according to slot number as shown in Figure 2-2 . For example, the ports 0– 7 are always associated with the I/O blade in slot #1; ports 8 –15 are always associated with slo t #2, and so on.
2 – General Descrip tion Chassis Controls and LEDs 2-4 59043-03 A D 2.2 Chassis Controls and LEDs The Maintenance button on the CPU module, shown in Figure 2-3 , is the only chassis control and is used to reset a switch or to recover a disabled switch.
2 – General Description Chassis Controls and LEDs 59043-03 A 2-5 D 2.2.1.1 Resetting a Switch T o reset the switch, use a pointed tool to press and relea se (less than 2 seconds) the Maintenance button.
2 – General Descrip tion Chassis Controls and LEDs 2-6 59043-03 A D 2.2.2 Chassis LEDs The chassis LEDs shown in Figure 2-4 provide status info rmation about switch operation. Refer to ”Port S tatus LED” on page 2-8 for in formation about the Port S tatus LED.
2 – General Description Fibre Channel Por ts 59043-03 A 2-7 D 2.2.2.3 Heartbeat LED (Amber) The Heartbeat LED indicates the st atus of the internal switch processor an d the results of the Po wer On Self T est (POST).
2 – General Descrip tion Fibre Channel Ports 2-8 59043-03 A D 2.3.1 Port S t atus LED The Port S tatus LED is a two-color LED that indicates both logg ed-in (or loop initialization) st atus and when the port is transmitting or receiving frames. Following a successful port login or loop initializa tion, the Port S tatus LED illuminates green.
2 – General Description Ethernet Port 59043-03 A 2-9 D 2.3.3 Port Modes SANbox2-64 switches support the following port mode s: Generic ports (GL_Port and G_Port) Fabric port s (FL_Port and F_Port) Expansion ports (E_Port) Switches come from the factory with a ll port s configured as GL_Ports.
2 – General Descrip tion Serial Port 2-10 59043-03 A D The Ethernet port has two LEDs: the Link S tatus LED (green) and the Activity LED (amber). The Link S tatus LED illumi nates con tinuously when an Ethernet connection has been est ablished. The Activity LED illuminates when dat a is being transmitted or received over the Ethernet connection.
2 – General Description Serial Port 59043-03 A 2-1 1 D Figure 2-8. Serial Port and Pin Identification The serial port connector requires a nul l-modem F/F DB9 cable. The pins on the switch RS-232 connector are shown in Figure 2-8 and identified in T able 2-1 .
2 – General Descrip tion Power Supply Modules 2-12 59043-03 A D 2.6 Power Supply Modules The power supply modules c onvert st andard 1 10 or 230 V AC to DC voltages for the various switch circuits. Each power supply module has an AC power receptacle and two st atus LEDs as shown in Figu re 2-9 .
2 – General Description Fans 59043-03 A 2-13 D 2.7 Fans The switch is equipped with three fans as shown in Figure 2-10 . If one of the fans should fail, the other two fans are cap able of providing the necessary cooling until the failed fan can be replaced.
2 – General Descrip tion Switch Management 2-14 59043-03 A D 2.8 Switch Management SANbox Manager is a workst ation-based Java® application that provides a graphical user interface for fabric management. T his application runs on a Windows®, Solaris™, or Linux® workst ation.
59043-03 A 3-1 Section 3 Planning Consider the following when planning a fabric: Devices Multiple chassis fabrics Performance Device access Fabric security Fabric management 3.1 Devices When planning a fabric, consider the number of devices and the anticip ated demand.
3 – Planning Devices 3-2 59043-03 A D When planning a fabric, consider how to create redundant p aths and minimize latency . Initiators and target s experience the least amount of latency when connected to the same I/O blade.
3 – Planning Devices 59043-03 A 3-3 D For a multiple switch fabrics in which initia tors on one switch communicate with target s on another , the same principles apply as shown in Figure 3-2 .
3 – Planning Multiple Chassis Fabrics 3-4 59043-03 A D 3.2 Multiple Chassis Fabrics By connecting switches together you can expand the number of available port s for devices. Each switch in t he fabric is identified by a unique domain ID, and th e fabric will automaticall y resolve domai n ID conflicts.
3 – Planning Multiple Chassis Fabrics 59043-03 A 3-5 D 3.2.2 Common T opologies The SANbox2-64 switch support s th ree commonly used fabric topologies: Cascade Mesh Multistage® A cascade topology describes a fab ric in which the switches are connected in a linear fashion.
3 – Planning Performance 3-6 59043-03 A D 3.3 Performance The SANbox2-64 switch support s class 2 and class 3 Fibre Channel service at transmission rates of 1 Gbp s or 2 Gbp s with a maximum frame size of 2148 bytes. A port can transmit or receive at 1 Gbp s or 2 Gbps depending on the device to which it is connected.
3 – Planning Performance 59043-03 A 3-7 D 3.3.2 Bandwid th Bandwidth is a me asure of the volume of dat a that can be transmitted at a give n transmission rate. A port can transmit or receive at 1 Gbps or 2 Gbp s depending on the device to which it is connected.
3 – Planning Device Access 3-8 59043-03 A D 3.4 Device Access Consider device access needs within the fa bric. Access is controlled by the use of zones and zone sets. Some zoning stra tegies include the following: Separate device s that use different o perating systems.
3 – Planning Device Access 59043-03 A 3-9 D 3.4.1 Sof t Zones Soft zoning divides the fabric for purpos es of controlling discove ry . Members of the same soft zone automatically discover and communicate freely with all other members of the same zone.
3 – Planning Device Access 3-10 59043-03 A D 3.4.3 V irtual Private Fabric Hard Zones Virtual Privat e Fabric (VPF) zoning divides the fabric for purposes of controlling discovery and both inbound and outbound traf fi c. This type of zoni ng is useful for providing security and reserving p aths between devices t o guarantee bandwidth.
3 – Planning Fabric Security 59043-03 A 3-1 1 D 3.5 Fabric Security An effective security profile begins with a se curity policy that states the requirements. A th reat analysis is needed to define the plan of action fo llowed by an implement ation that meets the se curity policy requirement s.
3 – Planning Fabric Security 3-12 59043-03 A D 3.5.2 Device Security Device security provides for the authorization and a uthentication of devices that you attach to a switch.
3 – Planning Fabric Security 59043-03 A 3-13 D Figure 3-3. Security E xample: Switches and HBAs 1. Create a security set (Security_Set_1) on Switch_1. 2. Create a port group (Group_Port) in Security_ Set_1 with Switch_1, and HBA_1 as members. Because the JBOD is a loop device, it is excluded from the port group.
3 – Planning Fabric Security 3-14 59043-03 A D 3. Create an ISL group (Group_ISL) in Se curity_Set_1 with Switch_2 as its member . Only Switch_2 need be a memb er because there is no authentication between the switches. 4. Configure security on HBA_1 using the appropriate management tool.
3 – Planning Fabric Security 59043-03 A 3-15 D 3.5.2.2 Security Example: Host Authentication Consider the fabric shown in Figure 3-4 . In th is fabric, only Switch_2 and HBA_2/APP_2 support security , where APP_2 is a host application.
3 – Planning Fabric Security 3-16 59043-03 A D 2. Create a Management Server group (Group_1 ) in Security_Set_2 with Switch_2 and HBA_2 or APP_2 as its member . Y ou must specify HBAs by node wo rldwide name. Switch es can be specified by port or node worldwide name.
3 – Planning Fabric Manageme nt 59043-03 A 3-17 D 3.5.3 Fabric Services Fabric services include security-relate d functions such as inband management and SNMP . Inband man agement is the ability to manage switches across inter-switch links using SANbox Manager , SNMP , management server , or the application programming interface.
3 – Planning Fabric Managem ent 3-18 59043-03 A D Notes.
59043-03 A 4-1 Section 4 Installation This section describes how to insta ll and configure the SANbox2-64 switch. It also describes how to load new firmware and how to recove r a disabled switch.
4 – Installation Installing a Switch 4-2 59043-03 A D 4.1.3 Environment al Conditions Consider the factors that affect the climat e in your facility such as equipment heat dissipation and ventilation.
4 – Installation Installing a Switch 59043-03 A 4-3 D Installing a SANbox2-64 switch involves the following step s: 1. Mount the switch. 2. Install SFP transceivers. 3. Connect the switch to the AC power source. 4. Connect the management workst ation to the switch.
4 – Installation Installing a Switch 4-4 59043-03 A D The switch is designed to be mounted in a rack using the mounting bracket s and the SANbox2-64 rail kit shown in Figure 4-2 . T o mount the switch in a rack, do the following. Rack mounting instructions can also be found in the SANbox2-64 Rack Mounting Guide packa ged with the switch.
4 – Installation Installing a Switch 59043-03 A 4-5 D Figure 4-2. SAN box2-64 Rail Kit 1. Y ou can install the switch in a rack “fans first” or “faceplate first”.
4 – Installation Installing a Switch 4-6 59043-03 A D 4. Slide the switch and rail assembly in to the rack rails. Fasten the switch to the rack with two screws (10), one through each bracket . 4.2.2 Inst all SFP T ransceivers The switch has been valida ted with transceivers that support a variety of interconnection media.
4 – Installation Installing a Switch 59043-03 A 4-7 D T o connect the switch to an AC power sou rce and energize the switch, do the following: A VERTISSEMENT!! Pour la sécurité de l’utilisateur , l’appareil est livré avec un câble d’alimentation trifilaire et une fiche.
4 – Installation Installing a Switch 4-8 59043-03 A D 1. Connect the power cords to the AC power recept acles on the front of the switch chassis. 2. Connect each power cord to a 3-wire, grounded, AC outlet that delivers power in accordance with the power re quirements in Appendix A S pecifications .
4 – Installation Installing a Switch 59043-03 A 4-9 D 4.2.4 Connect the Manage ment Wo rkst ation to the Switch Connect the management workst ation to the switch in one of three ways: Indirect Ethernet connection from the management wo rkstation to the switch RJ-45 Ethernet connector through an Ethernet switch or a hub.
4 – Installation Installing a Switch 4-10 59043-03 A D 4.2.4.1 Ethernet Connection T o establish an Ethernet connectio n, do the following: 1. Connect a 10/100 Base-T cross-over cable from an RJ-45 port on the management workst ation directly to the RJ-45 Ethernet port ; or a 10/100 Base-T straight cable indirectly over an Ethernet ne twork.
4 – Installation Installing a Switch 59043-03 A 4-1 1 D For Linux: a. Set up minicom to use the serial port. Cre ate or modify the /etc/minirc.dfl file with the following content: pr portdev/ttyS0 pu minit pu mreset pu mhangup b. V erify that all users have perm ission to run minicom.
4 – Installation Installing a Switch 4-12 59043-03 A D 4.2.6 SANsurfer Management Suite Disk - Windows Inst allation T o install the SANbox Mana ger application on Windows from the SANsurfer® Management Suite Disk, do the following: 1.
4 – Installation Installing a Switch 59043-03 A 4-13 D b. Mount the CD-ROM. From a she ll prompt, enter the following command: mount /mnt/cdrom c. Exe cute your web browser to view the S t art_Here.htm document using one of the following commands: $mozilla file:/mnt/cdrom/Start_Here.
4 – Installation Installing a Switch 4-14 59043-03 A D c. In File Manag er , double-click the CD-ROM icon, and then double-click the Sansurfer folder . d. In the Sansurfer folder , double-click the S t art_Here.htm file to open the SANsurfer Management Suite st art page in your defa ult browser .
4 – Installation Installing a Switch 59043-03 A 4-15 D 4.2.10 SANbox2 Inst allation Di sk - Linux Inst allation T o install the SANbox Manager application on Linux from the SANbox2 Insta llation Disk, do the following: 1. Close all programs currently runni ng, and insert the SANbox2 Installation Disk into the management workst ation CD-ROM drive.
4 – Installation Installing a Switch 4-16 59043-03 A D leave the login name and p assword fields empty , and choose the Add Fabric button. By default, user authentication is disabled, and there fore, the Admin account name and p assword are used. Refer to the ”Set Setup Command” on page B-58 for information about setting fabric securit y .
4 – Installation Install Firmware 59043-03 A 4-17 D 4.3 Inst all Firmware The switch comes with current firmware inst alled. Y ou can upgrade the firmware from the management workst ation as new fi rmware becomes available.
4 – Installation Install Firmware 4-18 59043-03 A D 4.3.2 Using the CLI to Inst all Firmware T o install firmware using the CLI when an FTP server is present on the management workst ation, do the following: 1. Connect to the switch through the Eth ernet or the serial port and open a T elnet session.
4 – Installation Install Firmware 59043-03 A 4-19 D 4.3.3 Using FTP and the CLI to Inst all Firmware T o install firmware using the CLI when the management workstation doe s not have an FTP server , do the following: 1. Connect to the switch through the Eth ernet or the serial port.
4 – Installation Powering Down a Switch 4-20 59043-03 A D 10. Display the list of firmware image files on the switch to confirm that the file was loaded. Refer to the ”Image Command” o n page B-23 for more information. SANbox2 (admin) $>image list 1 1.
59043-03 A 5-1 Section 5 Diagnostics/T roubleshooting Diagnostic information ab out the switch is available through the chassis LEDs, the power supply LEDs, and the Port S tatus LED. Diagnostic information is also available through the SANbox Manager a nd CLI event logs and error displays.
5 – Diagnostics/T roubleshoo ting POST Diagnostics 5-2 59043-03 A D 5.1.1.2 Maintenance Mode Pattern S teady illumination indicates that the switch is in maintenance mode, which returns the switch IP address to 10.
5 – Diagnostics/Trou bleshooting POST Diagnostics 59043-03 A 5-3 D 1. Open a T elnet session and use the S hutdown co mmand to close activity on the switch, then power down the switch. Refer to the ”Shut down Command” on page B-88 . 2. Place the switch in mainten ance mode.
5 – Diagnostics/T roubleshoo ting POST Diagnostics 5-4 59043-03 A D b. Enter the following account name and p assword: user: images password: images c. Act ivate binary mode and copy the configuration file from the workstation to the switch. The configuration file must be n amed "configdata".
5 – Diagnostics/Trou bleshooting POST Diagnostics 59043-03 A 5-5 D 5.1.2 Port S t atus LED Indications Port diagnostics for each port are indicated b y the Port S tatus LED as shown in Figure 5-1 . Figure 5-1. Port S tatus LED The Port S tatus LED has thre e indications: Logged in - Continuous illumination.
5 – Diagnostics/T roubleshoo ting POST Diagnostics 5-6 59043-03 A D the Show Alarm command. Pertinent alarm messages will point to one or more of the following conditions: E_Port isolation Excessive port errors 5.1.2.1 E_Port Isolation A Port S tatus LED error indication is of ten the result of E_Port isolation.
5 – Diagnostics/Trou bleshooting POST Diagnostics 59043-03 A 5-7 D Y es - Cont act your authorized maintenance provider . No - Deactivate one of the active zone set s or edit the conflicting zones so that their membership is the same. Reset the port.
5 – Diagnostics/T roubleshoo ting POST Diagnostics 5-8 59043-03 A D Review the event browser to determine if excessive port errors are responsible for disabling the port. Look for a message that mentions one of the monitored error types indicating that the port has been disabled, then do th e following: 1.
5 – Diagnostics/Trou bleshooting Chassis Diagnostics 59043-03 A 5-9 D 5.2 Chassis Diagnostics Chassis diagnostics are indicated by the chassis and power supply LEDs as shown in Figure 5-3 .
5 – Diagnostics/T roubleshoo ting Chassis Diagnostics 5-10 59043-03 A D 5.2.1 Over T emperature LED is Illuminated The Over T emperature LED illum inates to indicate that t he switch logic circuitry is overheating. If the Over T emperature LED illuminates, do the following: 1.
5 – Diagnostics/Trou bleshooting Chassis Diagnostics 59043-03 A 5-1 1 D 5.2.4 Output Power LED Is Extinguished The Output Power LED illuminates to ind icate that the power supply is producing the proper voltag es. If the Output Power LED is extinguished, do the following: 1.
5 – Diagnostics/T roubleshoo ting Recovering a Switch 5-12 59043-03 A D 5.3 Recovering a Switch A switch can become inoperable or unma nageable for the following reasons: Firmware becomes corrup.
5 – Diagnostics/Trou bleshooting Recovering a Switch 59043-03 A 5-13 D 5. The maintenance menu displays several recovery op tions. T o select a switch recovery option, press the co rresponding number (displayed in option: field) on the keyboard and p ress the Enter key .
5 – Diagnostics/T roubleshoo ting Recovering a Switch 5-14 59043-03 A D 5.3.3 Maintenance – Reset Network Config This option reset s the network properties to the factory default values and saves them on the switch. Refer to T able B-10 for the default network configuration values.
5 – Diagnostics/Trou bleshooting Recovering a Switch 59043-03 A 5-15 D 5.3.9 Maintenance – Show Firmware V ersions This option displays the imag e numbers and firmware versions that are stored on the switch. 5.3.10 Maintenance – Set Active Image This option specifies the firmware version to be used when the switch returns to normal operation.
5 – Diagnostics/T roubleshoo ting Recovering a Switch 5-16 59043-03 A D Notes.
59043-03 A 6-1 Section 6 Removal/Replacement This section describes the removal and r eplacement procedures for the following field replaceable units (FRU): SFP transceivers CPU module I/O.
6 – Removal/Rep lacement CPU Module 6-2 59043-03 A D 6.2 CPU Module The CPU module is equipped with a battery that powers the no n-volatile memory . This memory stores the switch configuration. 6.2.1 Removing the CPU Module T o remove the CPU module, do the follo wing: 1.
6 – Removal/Replacement CPU Module 59043-03 A 6-3 D 2. Configure the T elnet window to log output to a file. Ente r the Show Support command to document the switch and capture the o utput on a file.
6 – Removal/Rep lacement CPU Module 6-4 59043-03 A D Figure 6-1. Remo ving the CPU Module 9. T o remove the CPU module, grasp the la tch and rotate it downward to disengage the CPU module from the backplane co nnector . Carefully slide the CPU module out of the slot.
6 – Removal/Replacement CPU Module 59043-03 A 6-5 D 5. V erify the POST results. Open a T elnet session with the default IP address (10.0.0.1), and enter the Sh ow Slot command to display the diagnostic status for the CPU mod ule. Refer to the ”Show Command” on p age B-63 .
6 – Removal/Rep lacement CPU Module 6-6 59043-03 A D 4) Copy Log Files 5) Remove Switch Config 6) Remake Filesystem 7) Reset Switch 8) Show Firmware Versions 9) Set Active Image Option: 1 Image filename: image_file Unpacking ’filename’, please wait.
6 – Removal/Replacement I/O Blades 59043-03 A 6-7 D 6.3 I/O Blades Y ou can remove and inst all I/O blades while the switch is operating. The following instructions assume that the switch is oper ating.
6 – Removal/Rep lacement I/O Blades 6-8 59043-03 A D 5. Choose the slot number (6 for example). Which IO blade (indexed by slot number) do you want to replace? (1,2,3,4,6,7,8,9): [1] 6 6. Disconnect all cables fr om the selected I/O blade. Remove all connections from the IO blade in slot 6.
6 – Removal/Replacement I/O Blades 59043-03 A 6-9 D Figure 6-2. Removi ng an I/O Blade 8. T o install a new I/O blade, en ter “y”. Do you want to continue with the replacement procedure? (y=proceed/n=cancel) y 9. Slide the I/O blade into the slot g uide until it makes contact with the backplane connecto r .
6 – Removal/Rep lacement I/O Blades 6-10 59043-03 A D 10. V erify the POST results. The I/O blade d iagnostic status appears in the dialog. The status should be "Passed". Hotswap IO blade process successfully completed. Diagnostics has been run on the IO blade in slot 6: Passed 1 1.
6 – Removal/Replacement Cross-Connect Blades 59043-03 A 6-1 1 D 6.4 Cross-Connect Blades The SANbox2-64 switch contains two CC blades: one in slot 1 1 (CC blade 0) and the other in slot 12 (CC blade 1) as shown in Figure 6-3 . Y ou access slot 1 1 by removing the top-rear switch cover .
6 – Removal/Rep lacement Cross-Connect Blades 6-12 59043-03 A D 6.4.1 Removing a CC Blade T o remove a CC blade, do the following: 1. Power down the switch. Isolate t he switch from the fabric. Open a T elnet session and enter the Shut down command.
6 – Removal/Replacement Cross-Connect Blades 59043-03 A 6-13 D 6. Remove the switch cover . Use a medium crosshead screw driver to remove the four screws on each side and the six screws on top as shown in Figure 6-4 . Lift and remove the switch cover and set it aside.
6 – Removal/Rep lacement Cross-Connect Blades 6-14 59043-03 A D 8. Disconnect the CC blade from backp lane. Grasp both latches with the thumbs. Open both latches together a little at a time to disengage the CC blade from the backplane. 9. Lift CC blade from switch .
6 – Removal/Replacement Cross-Connect Blades 59043-03 A 6-15 D 5. With an assistant, slide the switch into the rack. Fasten the switch b rackets to the rack with screws. 6. Reconnect the Ethernet cable to the CPU module. Reconnect the power cords to the power supply modules to p ower up the switch.
6 – Removal/Rep lacement Power Supply Modules 6-16 59043-03 A D 6.5 Power Supply Modules The power supply modules are hot pluggable. This mea ns you can remove or install one of the two f unctioning power suppl y modules without disrupting service.
6 – Removal/Replacement Power Supply Modules 59043-03 A 6-17 D 1. Disconnect the power cord from t he power supply module. 2. Connect an ESD wrist strap to the groun d jack on the CPU module sh own in Figure 6-7 or some other ground point on the chassis.
6 – Removal/Rep lacement Fans 6-18 59043-03 A D 6.5.2 Inst alling a Power Supply Module T o install a power supply module, do the following : 1. Slide the power supply module into the slot guide until it contacts the backplane. 2. Rotate the bla de latch upward to lock the power supply module in place.
6 – Removal/Replacement Fans 59043-03 A 6-19 D 6.6.1 Removing a Fan T o remove a fan, loosen the two captive screws shown in Figure 6-8 with a flat- blade screw driver . Grasp the fan by the screws and pull firmly to disengage the fan from the backplane connector .
6 – Removal/Rep lacement Fans 6-20 59043-03 A D 6.6.2 Inst alling a Fan T o install a fan, do the f ollowing: 1. Confirm that the new fan has the same air flow direction as the old fan. Each fan has a part number label indicat ing the air flow direction as shown in Figure 6-9 .
59043-03 A A-1 Appendix A S pecifications This appendix contain s the specificati ons for the SANbox2-64 Fibre Ch annel switch. Refer to Section 2 General Description for the location of all connections, switches, controls, and component s. A.1 Fabric S pecifications Fibre Channel Protocols .
A – Specifications Maintainability A-2 59043-03 A D A.2 Maint ainability Maximum User Ports ...................... > 475,000 ports depending on confi gurati on Buffer Cre dits .................................. 12 buf fer credits per port Media T ype .
A – Specifications Fabric Manageme nt 59043-03 A A-3 D A.3 Fabric Management A.4 Dimensions A.5 Electrical Management Methods .................... SANbox Mana ger Graphical User Interface Application Programming Interface Command Line Interface GS-3 Management Server SNMP FTP Maintenance Connection .
A – Specifications Environmental A-4 59043-03 A D A.6 Environment al T emperature Operating ........................... ....... Non-operating ........................... 5 to 40°C (41 to 104°F) - 40 to 70°C (-40 to 158°F) Humidity Operating .
A – Specifications Regulatory Certifications 59043-03 A A-5 D A.7 Regulatory Certifications Safety S tandards ............................ UL1950, CSA 22.2 No. 95 0, EN60950 Emissions S tandards ...................... FCC Part 15B Class A VCCI Class A ITE BSMI Class A CISPR 22, Class A EN 55022, Class A V oltage Fluctuations .
A – Specifications Shortwave Laser SFP 1G/2G (multi-mo de) A-6 59043-03 A D A.8 Shortwave Laser SFP 1G/2G (multi-mode) Connector ....................................... Duplex LC Color coding.................................... Beige or black exposed connector surfaces Cable .
A – Specifications Longwave Laser SF P 1G/2G (single-mode) 59043-03 A A-7 D A.9 Longwave Laser SFP 1G/2G (single-mode) Connector ....................................... Duplex LC Color coding.................................... Blue exposed connector surfaces Cable .
A – Specifications Longwave Laser SFP 1G/2G (single-mo de) A-8 59043-03 A D Notes.
59043-03 A B-1 Appendix B Command Line Interface Each switch contains a T elnet server . This server allows a T elnet client to estab lish a T elnet session with the switch to retrieve information or to configure paramete rs using the Command Line Interface (CLI).
B – Command Line Interface Command Syntax B-2 59043-03 A D B.2 Command Synt ax The command synt ax is as follows: command key word keyword [value] keyword [value1] [value2] The Command is followed by one or more keyw ords. Co nsider the following rules and conventions: Commands and keywords are case insensitive.
B – Command Line Interface Commands 59043-03 A B-3 D B.3 Commands The command set performs monitoring and configuration tasks. Commands related to monitoring t asks are availabl e to all account names. Commands related to configuration tasks are availab le only within an adm in session by account s with Admin authority .
B – Command Line Interface Admin Command B-4 59043-03 A D Admin Command Opens and closes an Admin session. The Admin session provides comma nds that change the fabric and swit ch confi gurations. Only one Admin session can be open on the switch at any time.
B – Command Line Interface Alias Command 59043-03 A B-5 D Alias Command Creates a named set of port s/devices. Aliases make it easier to assign a se t of ports/devices to many zon es.
B – Command Line Interface Alias Command B-6 59043-03 A D members [alias] Displays all members of the alias given by [alias]. This keyword is available with User authority and does n ot require a zoning edit session or an admin session.
B – Command Line Interface Config Command 59043-03 A B-7 D Config Command Manages the Fibre Channel con figurations on a switch. For information about setting the port and switch configu rations, refer to the ”Set Config Command” on page B-4 2 .
B – Command Line Interface Config Command B-8 59043-03 A D restore Restores configuration settings to an out-of-band switch from a backup file named configdata , which must b e first uploaded on the switch using FTP . Y ou create the backup file using the Config Backup command.
B – Command Line Interface Config Command 59043-03 A B-9 D The following is an example of how to cre ate a backup file (configdata) and download the file to the workst ation.
B – Command Line Interface Date Command B-10 59043-03 A D Date Command This command displays or set s the system date and time. T o set the date and time the information string must be provid ed in this format: MMDDhhmmCCYY . The new date and time t akes ef fect immediately .
B – Command Line Interface Fallback Command 59043-03 A B-1 1 D Fallback Command Assigns the pending firmware st atus back and forth between the active and inactive firmware images stored in switch memory .
B – Command Line Interface Group Command B-12 59043-03 A D Group Command Creates group s, manages membership within the group, and manages the membership of gr oups in security s ets. Authority Admin session and a Security Edit session. Refe r to the ”Security Command” on page B-3 5 for information about starting a Security Edit sessio n.
B – Command Line Interface Group Command 59043-03 A B-13 D copy [group_source] [group_destination] Creates a new grou p named [group_destination] and copies the membership into it from the group given by [group_source]. create [group] [type] Creates a group with the name given by [group] with the type given by [type].
B – Command Line Interface Group Command B-14 59043-03 A D members [group] Displays all members of the group given by [group]. This keyword is available without an Admin session. remove [group] [members] Remove the port/device worldwide name gi ven by [member] from the group given by [group].
B – Command Line Interface Group Command 59043-03 A B-15 D The following is an example of the Gr oup Members command: SANbox2 #> group members group1 Current list of members for Group: group1 ---.
B – Command Line Interface Hardreset C ommand B-16 59043-03 A D Hardreset Command Resets the switch and performs a power-on self test. This reset activates the pending firmware and disrupt s traf fic.
B – Command Line Interface Help Command 59043-03 A B-17 D Help Command Displays a brief description of the specifie d command and it s keywords. Authority None Synt ax help [command] [keyword] Keywords [command] Displays a summary of the comman d given by [command] and it s keywords.
B – Command Line Interface Help Command B-18 59043-03 A D The following is an example of the Help Set Beacon command: SANbox2 #> help set beacon set beacon On | Off This command allows the LEDs on the front of the switch to flash. The On option will start and the Off option will stop the flashing.
B – Command Line Interface History Command 59043-03 A B-19 D History Command Displays a numbered list of the previously e ntered commands from which you can re-execute selected commands.
B – Command Line Interface Hotreset Command B-20 59043-03 A D Hotreset Command Resets the switch for th e purpose of activating the pen ding firmware without disrupting traf fic. This command termi nates all management sessions and saves all configuration information.
B – Command Line Interface Hotswap Command 59043-03 A B-21 D Hot swap Command This command prompts you step-by-ste p through the procedure to replace an I/O blade, insert an I/O blade, or remove an I/O blade while the switch is running.
B – Command Line Interface Hotswap Command B-22 59043-03 A D to replace? (1,2,3,4,6,7,8,9): [1] 6 o Remove all connections from the IO blade in slot 6. o Remove the IO blade in slot 6 from the chassis. Have the above operations been completed? (y = proceed / n = cancel) y Hotswap IO blade removal sub-procedure successfully completed.
B – Command Line Interface Image Command 59043-03 A B-23 D Image Command Manages and insta lls switch firmware. Authority Admin session Synt ax image cleanup fetch [account_name] [ ip_address] [file_source] [file_destination] list unpack [file ] Keywords cleanup Removes all firmware image files from the switch.
B – Command Line Interface Lip Command B-24 59043-03 A D Lip Command Reinitializes the specified loop port. Authority Admin session Synt ax lip [port_number] Keywords [port_number] The number of the port to be reinitialize d.
B – Command Line Interface Passwd Command 59043-03 A B-25 D Passwd Command Changes a user account’ s pa ssword. Authority Admin account name and an admin se ssion to change another account’ s password; Y ou can change you own password with out an Admin session.
B – Command Line Interface Ping Command B-26 59043-03 A D Ping Command Initiates an attempt to communicate with a nother switch in the fabric and reports the result. Authority None Synt ax Ping ip_address Keywords ip_address The IP address of the switch to qu ery .
B – Command Line Interface Ps Command 59043-03 A B-27 D Ps Command Displays current system process information. Authority None Synt ax ps Examples The following is an example of the Ps command: SANbox2 #> ps PID PPID %CPU TIME ELAPSED COMMAND 338 327 0.
B – Command Line Interface Quit Command B-28 59043-03 A D Quit Command Closes the T elnet session. Authority None Synt ax quit, exit, or logout Notes Y ou can also enter Control-D to close the T elnet session.
B – Command Line Interface Reset Com mand 59043-03 A B-29 D Reset Command Resets the switch configuration pa rameters. If you omit the keyword, th e default is Reset Switch.
B – Command Line Interface Reset Command B-30 59043-03 A D switch Resets the switch witho ut a power-on self test. This reset disrupts traf fic and activates the pending firmware. Thi s command also closes all management sessions. This is the default.
B – Command Line Interface Reset Com mand 59043-03 A B-31 D T able B-6. Port Configuration Defaults Parameter Default Admin S tate Online Link S peed Auto Port T y pe GL Symbolic Name Port ALFairnes.
B – Command Line Interface Reset Command B-32 59043-03 A D T able B-7. Alarm Threshold Configuration Defaults Parameter Default ThresholdMonito ringEnabled False CRCErrorsMonitoringEn abled RisingT .
B – Command Line Interface Reset Com mand 59043-03 A B-33 D T able B-9. SNMP Configuration Defaults Parameter Default SNMPEnabled T rue Contact <syscontact undefined > Location <sysLoca tion undefine d> Description QLogic SANbox2 FC Switch T rap [1-5] Address T rap 1: 10.
B – Command Line Interface Reset Command B-34 59043-03 A D T able B-10. System Configuration Defaults Parameter Default Ethernet Network Discovery S tatic Ethernet Network IP Address 10.0.0.1 Ethernet Network IP Mask 255.0.0.0 Ethernet Gateway Address 10.
B – Command Line Interface Security Command 59043-03 A B-35 D Security Command Opens a Security Edit session in which to manage the securit y database on a switch. Refer to the ”Group Comman d” on page B-12 and the ”Securityset Command” on page B-38 .
B – Command Line Interface Security Command B-36 59043-03 A D history Displays history information about the security d atabase and the active security set including the account name tha t made changes and when those changes were made. This keyword does not require an Ad min session.
B – Command Line Interface Security Command 59043-03 A B-37 D The following is an example of the Secu rity Limits command: SANbox2 #> security limits Security Attribute Maximum Current [Name] ---.
B – Command Line Interface Securityset Command B-38 59043-03 A D Securityset Command Manages security sets in the secu rity database. Authority Admin session and a Security Edit session. Refe r to the ”Security Command” on page B-3 5 for information about starting a Security Edit sessio n.
B – Command Line Interface Security set Command 59043-03 A B-39 D del ete [security_set] Deletes the security set given by [securit y_set ]. If the specified security set is active, the command is suspended until th e security set is deactivated.
B – Command Line Interface Set Command B-40 59043-03 A D Set Command Sets a vari ety of switch param eters. Authority Admin session for all keywords except Alarm Clear , Beacon, and Pagebreak which are available without an Admin session.
B – Command Line Interface Set Comman d 59043-03 A B-41 D log [option] S pecifies the type of entries to be entered in th e event log. Refer to the ”Set Log Command” on page B-54 . p agebreak [st ate] S pecifies how much information is displayed on the screen at a time accord ing to the value given by [state].
B – Command Line Interface Set Config Command B-42 59043-03 A D Set Config Command Sets switch, blade, po rt, alarm threshold, security , and zoning configuration parameters.
B – Command Line Interface Set Config Command 59043-03 A B-43 D PortT ype Port mode: GL, G , F , FL, Don or . The default is GL. SymbolicPortName Descriptive name. The default is Por t. ALFairness Arbitration loop fairness. Enables (T rue) or disables (False) the switch’ s priority to arbitrat e on the lo op.
B – Command Line Interface Set Config Command B-44 59043-03 A D MFSEnable Multi-Frame Se quence bundling. Prevents (T rue) or allows (False) the interleaving of fr ames in a sequence. The default is T rue. Enabling MFSEnable disables LC FEnable an d VIEnable.
B – Command Line Interface Set Config Command 59043-03 A B-45 D security Initiates an editing session in which to change the security settings. The system displays each parameter one line at a time and prompts you for a value. For each parameter , enter a new value or press the Enter key to accept th e current value shown in brackets.
B – Command Line Interface Set Config Command B-46 59043-03 A D switch Initiates an editing session in which to change switch configuration settings. The system displays each p arameter one line at a time and prompts yo u for a value. For each pa rameter , enter a new value or press the Enter key to accept the current value shown in bracket s.
B – Command Line Interface Set Config Command 59043-03 A B-47 D threshold Initiates a configuration session by which to gene rate and log alarms for selected events. The system d isplays each event, it s thresholds, and sampling interval one line at a time and prompt s you for a value.
B – Command Line Interface Set Config Command B-48 59043-03 A D T able B-15. Set Config Threshold Paramete rs Parameter Description Threshold Mo nitoring Enabled Master enable /disable par ameter for all events. Ena bles (T rue) or disables (False) the generation of all enabled event alarms.
B – Command Line Interface Set Config Command 59043-03 A B-49 D zoning Initiates an editing session in which to change switch zoning attributes. The system displays each p arameter one line at a time and prompts yo u for a value. For each pa rameter , enter a new value or press the Enter key to accept the current value shown in bracket s.
B – Command Line Interface Set Config Command B-50 59043-03 A D The following is an example of the Set Config Port command: SANbox2 #> admin start SANbox2 (admin) #> config edit SANbox2 (admin-config) #> set config port 1 A list of attributes with formatting and current values will follow.
B – Command Line Interface Set Config Command 59043-03 A B-51 D The following is and example of the Set Config Security command: SANbox2 (admin-config) #> set config security A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value.
B – Command Line Interface Set Config Command B-52 59043-03 A D The following is an example of the Set Config Thre shold command: SANbox2 #> admin start SANbox2 (admin) #> config edit SANbox2 (admin-config) #> set config threshold A list of attributes with formatting and current values will follow.
B – Command Line Interface Set Config Command 59043-03 A B-53 D Finished configuring attributes. This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect. To discard this configuration use the config cancel command.
B – Command Line Interface Set Log Command B-54 59043-03 A D Set Log Command S pecifies the type of entries to be entered in the event log. Log entries are created for ports, comp onents, and event severity levels.
B – Command Line Interface Set Log Command 59043-03 A B-55 D Other Monitors other mi scellaneous event s. Port Monitors all port event s Switch Monitors switch management event s.
B – Command Line Interface Set Log Command B-56 59043-03 A D st art S tarts the logging of events based on t he Port, Compone nt, and Level keywords assigned to the current configuration. T he logging continues until you e nter the Set Log S top command.
B – Command Line Interface Set Port Command 59043-03 A B-57 D Set Port Command Sets port st ate and speed for the specified por t temporarily until the next switch reset or new configuration activation.
B – Command Line Interface Set Setup Command B-58 59043-03 A D Set Setup Command Changes SNMP and system configuration settings. The swit ch maintains one SNMP configuration and one system configuration.
B – Command Line Interface Set Setup Command 59043-03 A B-59 D system Prompts you in a line-by-lin e fashion to change system configuration settings. T able B-18 describes the system configuration fields. For each parameter , enter a new value or press the Enter key to accept the current value shown in bracket s.
B – Command Line Interface Set Setup Command B-60 59043-03 A D Examples The following is a n example of the Set Setup SNMP command: SANbox2 #> admin start SANbox2 (admin) #> set setup snmp A list of attributes with formatting and current values will follow.
B – Command Line Interface Set Setup Command 59043-03 A B-61 D Trap1Severity (see allowed options above) [warning ] Trap1Version (1 / 2) [2 ] Trap1Enabled (True / False) [False ] Trap2Address (dot-notated IP Address) [0.
B – Command Line Interface Set Setup Command B-62 59043-03 A D The following is an example of the Set Setu p System command: SANbox2 (admin) #> set setup system A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value.
B – Command Line Interface Show Command 59043-03 A B-63 D Show Command Displays fabric, switch, and port operational inf ormation. Authority None Synt ax show about alarm blade broadcast chassis con.
B – Command Line Interface Show Command B-64 59043-03 A D chassis Displays chassis component sta tus and temperature. config [option] Displays switch, port, and zoning configuration attributes. Refer to the ”Show Config Command” on page B-78 . domains Displays list of each domain and it s worldwide name in the fabric.
B – Command Line Interface Show Command 59043-03 A B-65 D [domain_id] Displays name server information fo r the switch given by [domain_id]. [domain_id] is a switch domain ID. [port_id] Displays name server information for the port given by [port_id].
B – Command Line Interface Show Command B-66 59043-03 A D FBusy Number of times the swit ch sent a F_BSY because Class 2 frame could not be delivere d within ED_TOV time. Number of class 2 and class 3 f abric busy (F_BSY) frames generated by this por t in response to incoming fra mes.
B – Command Line Interface Show Command 59043-03 A B-67 D post log Displays the Power On Self T est (POST) log which contains result s from the POST . setup [option] Displays setup attributes for the system, SNMP , and the switch manufacturer . Refer to the ”Show Setup Command” on page B-85 .
B – Command Line Interface Show Command B-68 59043-03 A D steering [domain_id] Displays the routes that dat a takes to the switch given by [domain_id].
B – Command Line Interface Show Command 59043-03 A B-69 D Blade Slot Port Admin Oper Diag Temp Credit Type Number Range State State Status Status Pool ----- ------ ----- ----- ----- ------ ------ --.
B – Command Line Interface Show Command B-70 59043-03 A D The following is an example of the Show Domains comma nd: SANbox2 #> show domains Principal switch is (remote): 10:00:00:60:69:50:0b:6c U.
B – Command Line Interface Show Command 59043-03 A B-71 D The following is an example of the Show FDMI command: SANbox2 #> show fdmi HBA ID Manufacturer Model Ports -------- --------------- -----.
B – Command Line Interface Show Command B-72 59043-03 A D The following is an example of the Show NS [domain_ ID] command: SANbox2 #> show ns 18 Seq Domain Port Port No ID ID Type COS PortWWN Nod.
B – Command Line Interface Show Command 59043-03 A B-73 D The following is an example of the Show Port command: SANbox2 #> show port 1 Port Number: 1 ------------ AdminState Online PortID 150100 .
B – Command Line Interface Show Command B-74 59043-03 A D The following is an example of the Show Slot command: SANbox2 #> show slot Slot Blade Port Blade Diag Temp Credit Number Type Range Statu.
B – Command Line Interface Show Command 59043-03 A B-75 D The following is an example of the Show Switch co mmand: SANbox2 #> show switch Switch Information ------------------ SymbolicName sw .108 SwitchWWN 100000c0dd00bc56 SwitchType SANbox2-64 PROMVersion V2.
B – Command Line Interface Show Command B-76 59043-03 A D The following is an example of the Show T opology command for port 1: SANbox2 #> show topology 1 Local Link Information -----------------.
B – Command Line Interface Show Command 59043-03 A B-77 D The following is an example of the Show V ersion command: SANbox2 #> show version ***************************************************** *.
B – Command Line Interface Show Config Command B-78 59043-03 A D Show Config Command Displays switch, I/O blade, port, alarm threshold, security , and zoning for the current configuration.
B – Command Line Interface Show Config Command 59043-03 A B-79 D ExtCredit 0 FANEnabled True LCFEnabled False MFSEnabled True MSEnabled True NoClose False IOStreamGuard Disabled VIEnabled False The .
B – Command Line Interface Show Config Command B-80 59043-03 A D FallingTrigger 1 SampleWindow 10 DecodeErrorsMonitoringEnabled True RisingTrigger 25 FallingTrigger 0 SampleWindow 10 ISLMonitoringEn.
B – Command Line Interface Show Log Command 59043-03 A B-81 D Show Log Command Displays the content s of the log or the parameters use d to create entries in the log. The log contains a maximum of 200 en tries. When the log reaches it s entry capacity , subsequent entries overwrite the existing entries, beginning with the oldest.
B – Command Line Interface Show Log Comm and B-82 59043-03 A D The following is an example of the Show Log Options command: SANbox2 #> show log options Allowed options for log -------------------.
B – Command Line Interface Show Perf Command 59043-03 A B-83 D Show Perf Command Displays port performance in frames/second and byt es/second. If you omit the keyword, the command displays dat a transmitted (out), dat a received (in), and total dat a transmitted and received in frames/second and byt es per second.
B – Command Line Interface Show Perf Command B-84 59043-03 A D errors [port_number] Displays continuous error counts for the set of 16 ports (0–15, 16– 31, ...) that include [port_number]. If you omit [port_ number], ports 0–15 are displayed. T ype “q” and press the Enter key to stop the display .
B – Command Line Interface Show Setup Command 59043-03 A B-85 D Show Setup Command Displays the current SNMP and system settin gs. Authority None Synt ax show setup mfg snmp system Keywords mfg Displays manufacturing information about the switch . snmp Displays the current SNMP settings.
B – Command Line Interface Show Setup Command B-86 59043-03 A D The following is an example of the Show Setup Snmp command: SANbox2 #> show setup snmp SNMP Information ---------------- SNMPEnabled True Contact <sysContact undefined> Location N_107 System Test Lab Description QLogic SANbox2 FC Switch Trap1Address 10.
B – Command Line Interface Show Setup Command 59043-03 A B-87 D The following is an example of the Show Setup System command: SANbox2 #> show setup system System Information ------------------ Eth0NetworkDiscovery Static Eth0NetworkAddress 10.20.
B – Command Line Interface Shutdown Command B-88 59043-03 A D Shut down Command T erminates all data transfers on the switch a t convenient points and closes th e T elnet session.
B – Command Line Interface Test Command 59043-03 A B-89 D T est Command T ests I/O blades and port s using internal (SerDes level), external (SFP), a nd online loopback test s. Internal and external tests require that the port be placed in diagnostic mode.
B – Command Line Interface Test Command B-90 59043-03 A D 3. Choose the type of port loopback test to ru n: T o run an internal loopback test, enter the followin g: test port x internal T o run an external loopback test, enter the following command.
B – Command Line Interface Test Command 59043-03 A B-91 D 3. A series of test pa rameters are displayed on the screen. Press the Enter key to accept each default p arameter value, or type a new value for each parameter and press th e Enter key .
B – Command Line Interface Uptime Command B-92 59043-03 A D Uptime Command Displays the elap sed up time since the switch was last reset and reset method. A hot reset or non-disruptive firmware activatio n does not reset the elapsed up time reported by this command.
B – Command Line Interface User Command 59043-03 A B-93 D User Command Administers and displays user account s. Authority Admin account name and an Admin session. The Account s and List keywords are available to all account names without an Admin session.
B – Command Line Interface User Command B-94 59043-03 A D Examples The following is an example of the User Accou nts command: SANbox2 (admin) #> user accounts Current list of user accounts ------.
B – Command Line Interface User Command 59043-03 A B-95 D The following is an example of the User Delete command : SANbox2 (admin) #> user del user3 The user account will be deleted.
B – Command Line Interface Whoami Command B-96 59043-03 A D Whoami Command Displays the account name, session numb er , and switch domain ID for the T elnet session.
B – Command Line Interface Zone Command 59043-03 A B-97 D Zone Command Manages zones and zone membership on a switch. T he Zone command defines members (ports /devices) for a single switch. Zones are members of zone set s. Authority Admin session and a Zoning Edit sessio n.
B – Command Line Interface Zone Command B-98 59043-03 A D list Displays a list of all zones and the zone set s of which they are members. Th is keyword does not require an Admin session. members [zone] Displays all members of the zone given by [zon e].
B – Command Line Interface Zone Command 59043-03 A B-99 D Examples The following is an example of the Zone List command: SANbox2 #> zone list Zone ZoneSet ------------------- wwn_b0241f zone_set_.
B – Command Line Interface Zone Command B-100 59043-03 A D The following is an example of th e Zone Zonesets command: SANbox2 #> zone zonesets zone1 Current List of ZoneSets for Zone: wwn_b0241f .
B – Command Line Interface Zoneset Com mand 59043-03 A B-101 D Zoneset Command Manages zone sets and zone set membership across the fabric. Authority Admin session and a Zoning Edit sessio n. Refer to the ”Zoning Command” on page B-1 04 for information about starting a Z oning Edit session.
B – Command Line Interface Zoneset Command B-102 59043-03 A D list Displays a list of all zone set s. This keyword does not require an Admin session. remove [zone_set] [zone_list] Removes a list of zones given by [zon e_list] from the zone set given by [zone_set].
B – Command Line Interface Zoneset Com mand 59043-03 A B-103 D The following is an example of the Zone set Zones command: SANbox2 #> zoneset zones ssss Current List of Zones for ZoneSet: ssss ---.
B – Command Line Interface Zoning Command B-104 59043-03 A D Zoning Command Opens a Zoning Edit session in which to create and manage zone set s and zones. Refer to the ”Zone Command” on page B-97 an d the ”Zoneset Command” on page B-1 01 . Authority Admin session.
B – Command Line Interface Zoning Command 59043-03 A B-105 D limit s Displays the number of zone set s, zones, aliases, members per zone, members per alias, and tot al members in the zoning database. This keyword a lso displays the zo ning databa se lim its.
B – Command Line Interface Zoning Command B-106 59043-03 A D 9 D_2_JBOD1 16 D_2_NewJBOD_2 5 E1JBOD1 5 E2JBOD2 3 LinkResetZone 3 LinkResetZone2 8 NewJBOD1 8 NewJBOD2 12 Q_1Photon1 12 Q_2Photon2 8 Q_1.
B – Command Line Interface Zoning Command 59043-03 A B-107 D wwn_2215c3 50:06:04:82:bf:d2:18:c2 50:06:04:82:bf:d2:18:d2 10:00:00:00:c9:22:15:c3 Configured Zoning Information ZoneSet Zone ZoneMember .
B – Command Line Interface Zoning Command B-108 59043-03 A D Notes.
59043-03 A Glossary-1 Glossary Access Control List Zone Access Control List zoning divides the fabric for purposes of controlling discovery and inbound traf fic. Active Zone Set The zone set that define s the current zoning for the fabric. Active Firmware The firmware image on the switch that is in use.
Glossary-2 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Class 3 Service A service which multiplexes frames at frame boundaries to or from one or more N_Ports without acknowledg ment. Configured Zone Set s The zone set s stored on a switch excluding the active zone set.
59043-03 A Glossary-3 SANbox2-64 Fibre Channel Switch Installation Guide D Frame Data unit consisting of a start-of-frame (SOF) delimiter , header , data p ayload, CRC, and an end-of-frame (EOF) delimiter . FRU Field Replaceable Unit Group A list of device worldwide names that are authorized to att ach to a switch.
Glossary-4 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D MIB Management Information Base Multist age T opology A fabric in which two or more edge switches connect to one or more core switches. NL_Port Node Loop Port. A Fibre Channel device port that supports arbitrated loop p rotocol.
59043-03 A Glossary-5 SANbox2-64 Fibre Channel Switch Installation Guide D User Account Security A component of fabric security that provides for the admin istration and authentication of account names, passwords, expiration dates, and authority level.
Glossary-6 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Notes.
59043-03 A Index- 1 Index Numerics 10/100 Base-T straight cable 4-9 A access 3-8 Access Control List zone 3-9 account name default B-1 description 3-11 display B-96 ftp 5-4 maintenance mode 5-12 Activ.
Index-2 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D activate B-7 backup B-7 copy B-7 delete B-7 edit B-7 file 5-3 file system error 2-4, 5-2 list B-7 remove 5-14 reset B-29 restore.
59043-03 A Index-3 SANbox2-64 Fibre Channel Switch Installation Guide D ports 2-7 protocols A-1 field replaceable unit 6-1 File T ransfer Protocol 4-19, 5-3 firmware display versions 5-15 failure 5-2 .
Index-4 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D link state dat abase B-64 Link S tatus LED 2-10 Lip command B-24 log archive B-54 clear B-54 copy 5-14 event B-54, B-81 power-on.
59043-03 A Index-5 SANbox2-64 Fibre Channel Switch Installation Guide D maximum number of ports/users A-2 modes 2-9 number 2-2 online test B-89 operational information B-65 performance B-65, B-83 seri.
Index-6 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Show command B-63 Show Config command B-78 Show Log command B-81 Show Perf command B-83 Show Setup command B-85 Shutdown command.
59043-03 A Index-7 SANbox2-64 Fibre Channel Switch Installation Guide D zone set 3-8 activate B-101 active B-104 add member zone B-101 copy B-101 create B-101 deactivate B-29, B-30, B-101 delete B-101.
Index-8 59043-03 A SANbox2-64 Fibre Channel Switch Installation Guide D Notes.
デバイスQ-Logic 64の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Q-Logic 64をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはQ-Logic 64の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Q-Logic 64の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Q-Logic 64で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Q-Logic 64を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はQ-Logic 64の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Q-Logic 64に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちQ-Logic 64デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。