GLX490 RM GALAXY HOOD GLASS Instructions Manual www.rangemaster.co.uk.
EN 2 2 Instructions Manual INDEX RECOMMENDATIONS A ND SUGGEST IONS ..................................................................................................................... 3 CHARACTER ISTICS ...............................................
EN 3 3 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of indivi dual f eatures that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liabl e for any damages resulting from incor- rect or improper installation.
EN 4 4 CHARACTERISTICS Dimensions.
EN 5 5 Components Ref. Q.ty Product components 1 1 Cooker hood with control unit, lights, blower unit, filters 2.1 1 Upper chimney 2.2 1 Lower chimney 8 1 Air outlet grid 9 1 Reducer flange Ø 150-120 10 1 Adapting ring ø 120-125 mm 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Cover for recycling version Ref.
EN 6 6 INSTALLATION Hood body moun ting • Firstly, it is necessa ry to adjust the two Vr- screws of the 11a- brackets, at minimun ( B ). • Hang the hood body on the two brackets 11a . • Connect the hood to the main s supply by means of a bipolar switch with at least 3 mm contact gap.
EN 7 7 RECYCLING VERSION AI R OUTLET To install the hood in recycling version, the optional charcoal filter kit must be purchased . • Remove the chimney angle bracket. • Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5).
EN 8 8 Flue assembly Upper exhaust flue • Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1 , making sure that they are we ll seated. • Secure the sides to the brackets u sing the 4 screws 12c (2,9 x 9,5) supplied.
EN 9 9 USE Control panel Key Function Display A Upper pan el closed: when pressed fo r about one sec- ond it opens the upper pan el. It switches the motor on at the late st sel ected sp eed. Upper panel open: when s hortly pressed it switches the motor on/off.
EN 1 10 REMOTE CONTROL (OPTIONAL) The appliance can be controll ed using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type. • Do not pl ace the remo te control near to h eat sources. • Used batteries must be disposed of in the proper manner.
EN 1 11 MAINTENANCE Metal grease filters Filters can be washed in the dish machine. They need to be washed when Drop- sign appears on the display or in any case every 2 months, or even more frequently in case of par ticularly intensive use of the hood.
EN 1 12 Charcoal filter (recycling version) This filter cannot be washed or regene rated. It must be replaced when the C appears on the display or at least once ever y 4 months.
EN 1 13 Replacing the fuser The hood panel opening and closing mechanism is con- trolled by a starter motor which is activated by a fuser. This fuser works only on the st arter motor. In case the fuser gets damaged when the panel is closed it is be necessary to manually unblock the panel.
.
.
436004217_v er1 AGA RANGEMASTER LTD..
デバイスRangemaster GLX490 RMの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rangemaster GLX490 RMをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRangemaster GLX490 RMの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rangemaster GLX490 RMの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rangemaster GLX490 RMで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rangemaster GLX490 RMを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRangemaster GLX490 RMの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rangemaster GLX490 RMに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRangemaster GLX490 RMデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。