T oilet Installation and Maintenance Instructions 1-800-352-5630 www.raritaneng. com Desription: Marine elegance toilet is available in 12V or 24V DC. Bowls are available in four models: standard with angled back, standard with straight back, tall with angled back and tall with straight back.
SAFETY 2 IMPOR T ANT SAFETY INSTRUCTIONS: W ARNING: Y oung children should NOT be left unsupervised around toilet. Serious injury or death could occur . Children can drown in water retained in the bowl. Seat and/or lid could close and strike child. Always replace circuit breaker and fuses with same rating .
OPERATION 3 A. Push Button Switch: Press push-button switch and hold until all waste is cleared from the toilet bowl. B. ME T oilet Contr ol: 1. Press and hold “W ater Only” to add water to the bowl 2 . Press and hold “Empty” to evacuate the bowl 3.
OPERATION 4 NOTE : Flush control is set at factory to work in most installations and no additional programming is needed. Use following instructions to re-program if adjustment on water levels and timings are needed.
WINTERIZING Winterizing: • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations.
SPECIFICA TIONS 6 Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size Plumbing NOTES: for Wiring t e e F 0 15 10 25 20 30 40 5 r e t e M 1 . 36 . 41 . 66 . 72 .
7 SPECIFICATIONS Additional Parts Required • 1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose • 3/4" (19 mm.) I.D. reinforced intake hose • 3/4" (19 mm.) and 1" (25 mm.) or 1 1/2" (38 mm.) hose clamps (two for each connection below waterline) • W ire • T erminals • Fuse/circuit breaker 14 NOTE: 12 1.
8 MOUNTING A. Preparation for Mounting T oilet Mounting surface must be flat and solid. Seat must open more than 90 degrees. 1. Place the toilet and mark mounting holes’ center line, and outside of the bowl (see FIG 1.) Draw a center line between two holes.
Discharge Lines 1 . Connect quality sanitation hose 1" (25 mm.) or 1 1/2”(38 mm.) discharge fitting on toilet. 2 . Run hose to appropriate device (i.e.: treatment system, holding tank, etc.). Inlet lines 1. Connect 1/2”(13 mm.) hose to pressurized supply or 3/4”(19 mm.
10 PLUMBING Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. 1. Connect hose from shut off valve to inlet port of water solenoid valve at the toilet. NOTE: T o avoid malfunction of water solenoid due to debris in water , installation of Freshwater Strainer (190601) is recommended.
WIRING C. Mounting controls: A. Push Button Switch: (see fig 1 1) • Mount Push Button Switch in an accessible location. • Make certain wires can be routed to Push Button Switch. • W ire terminals must have clearance when installed. 1 . Drill 5/8" (16mm) hole.
12 D. WIRING W ARNING: Hazard of Shock and Fir e • Always use proper wire, wire connectors and fuse/circuit br eaker . See Specification Chart. • Secur e wir e pr operly . • Do not connect appliances to toilet cir cuit. • Make sur e power is off before pr oceeding.
WIRING BA TTER Y Fuse RED Orange Black RED Black Solenoid valve Discharge pump Fig. 14 Wiring for Push Button Switch Fresh water model T o EST Discharge pump Black RED Blue Blue Black RED Fuse Pump Relay RED Push Button Push Button BA TTER Y 13 Fig.
WIRING 14 GND V alve- orange black red black red black BA TT - Pump - EST valve + pump + BA TT + panel holding tank full from EST to EST EXT TRIG BA TT FLUSH CONTROL P ANEL FUSE/BREAKER orange black red black red black panel tank full switch EST input BA TT FLUSH CONTROL P ANEL FUSE/BREAKER Relay PUMP remote Fig.
15 WIRING orange black black red black red FLUSH CONTROL P ANEL fuse/Breaker BA TT Control Box BA TT red blue FLUSH CONTROL P ANEL pump fuse/Breaker red orange black blue black red RED Relay Fig.
16 5 . Route wire from control per wiring diagrams. 6. Install seat. I nstall discharge support strap between seat nut and the bowl per Fig. 19A. 7 . Install toilet in place, connect hoses and wireplugs. (see Fig. 19) Caution: Do not pull on the discharge hose to avoid kinking 8 .
17 TROUBLESHOOTING WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the toilet, be sure that all power to the unit has been turned off. WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before work- ing on toilet.
EXPLODED PARTS Marine Elegance P ARTS LIST 2 2 1 10 0 T oilet Bowl,standard, angled, White(1) 221 100A T oilet bowl Bone(1) 2210012 Discharge Pump Assembly (1) 221012 MOTOR: 12 VDC (1) 221024 MOTOR: 2.
Marine Elegance Exploded Parts View 1222AW F172 F005 162325A 162305 162320 162310 162315 162420 162405 162415 162410 162425 F144 F162VT 163000 1660* M23A 162300W 162425 162425 162225 162135 162100W 16.
L460 0610vkm Specifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.
デバイスRaritan Engineering toiletの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raritan Engineering toiletをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaritan Engineering toiletの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raritan Engineering toiletの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raritan Engineering toiletで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raritan Engineering toiletを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaritan Engineering toiletの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raritan Engineering toiletに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaritan Engineering toiletデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。