IWAKI AMERICA FA-2E AIR DRIVEN BELLOWS PUMP INSTRUCTION MANUAL.
CONTENTS 1 INTRODUC TION ........................................................................................................ 3 2 UNPACKING AND IN SPECTION .............................................................................. 2 2.1 Operation Sequence .
1 INTRODUCTION Thank you for selecting an Iwaki America FA-2E Air Driven Bellows Pump. These pumps are designed exclusively for pumping semiconductor grade, high p uri ty liquids. To ensure safety and maximum service life of the pump, please read this instruction ma nual thoroughly prior to installat ion and operation.
2 2 UNPACKING AND INSPECTION Open the package and check that the product conforms to your order. Also check each of the following points. For any problem or inconsistency, contact Iwaki America at once. 1. Check that the model num ber indicated on the name plate conforms to the specifications of your order.
3 2.1 Operation Sequence Refer to Figure 2. When pressurized air is supp lied to chamber 'a' of the pump, bellows 'A' is compressed and fluid is discharged from the bellows through the pu mp head discharge (outlet) port.
4 2 IDENTIFICATION CODES 1 2 3 FA - 2E - W02 1. Series code: FA : Non-metallic pump for medium temperature liquid 2. Maximum discharge volume: 0.5 Gal/min (2L/min) 3. Special specifications No symbol: Threaded suction & discharge W02 : Tubing connections 3 SPECIFICATIONS 3.
5 3.2 Proximity Sensor Speci fications (for FA-2E pumps) Type High frequency oscillation switch Output system NPN DC open/close output Power source voltage 12-24 VDC ±10%, ripple (P-P): 10% max Current consumption 13 mA max Setting distance Less than 80% of the switching distance Hysteresis 10% max of detecting distance Switching distance 1.
6 3.3 FA-2E Pump Dimensions/Mass Mass: 8.6 lbs (3.7kg) Figure 4.
7 4 HANDLING PRECAUTIONS The following information deals with measures to ensure safe operation of the pump system. Please read the precautions carefully. To operate this pump, a 4-way solenoid valve and a controller (Iwaki America supplied m odel or host PLC) are required.
8 4.2 Pump Handling Precautions • Do not stop pump without opening discharge first: When stopping pump operation, first release pressure in the discharge line & then shut off supply air pressure. Residual pressure in the liquid discharge pi ping may result in deformation of the bellows due to the force of hydraulic pressure.
9 • Prohibited liquids: The following liquids must not be used: - Liquids that are easily crystallized - Liquids containing slurry - Solvent based fluids Service life of the valve and bellows is shortened by liquids that are easily crystallized or contain slurry.
10 4.4 Liquid Circulation Syst em Design Recommendations In typical semiconductor wet process liquids, a catalyst such as H 2 O, O 3 or H 2 O 2 is added to the process liquid. The subsequent reaction generates heat a nd produces extreme gassing of the liquid.
11 3. Another technique is to install an air detection sen sor in the suction port area, so that the auto valve is automatically opened by a signal sent out from the sen sor and the air elimination operation is initiated. 5 INSTALLATION, PIPING & WIRING 5.
12 5.2 Piping 5.2.1 General 1. Carry out sufficient air blowing or flushing of tubi ng and connectors to remove foreign m atter from inside surfaces prior to connecting them with the pump. 2. Tube connections should be done such that the extra load of pi ping is not applied to the pump, use pipe supports as necessary.
13 2. Install a filter or strainer with low piping resi stance on the sucti on piping to block the entrance of solid particles or wafer fragments. CAUTION! Wafer fragments inside the pump may get stuck in the bellows and cause damage.
14 5.2.3 Air Piping It is critical that all pneumatic piping and component s be sized according to the porting of the pum p. Full port components with matching effective cross-sectional area are recommended. 1. Effective cross-sectional area indicates th e capacity to allow air to flow freely.
15 2. Install a relief type regulating valve: Fluctuation of supply air pressure results in fluctu ation of the pum p stroke rate as well as discharge volume. Install a regulating valve to maintain the ai r pressure at a fixed level. Select the regulator based on the air consumption rate of the pump.
16 Figure 9 Pneumatic Piping/Control (FA-2E shown).
17 5.4 Wiring instructions 5.4.1 General A. Extension of leak detector electrode wire: Keep the resistance value at 5K ohms or below. A resistance greater than the above may make it impossible to detect a conductivity change between the leak detection electrodes.
18 5.4.5 Wiring for proximity sensor CAUTION! The proximity sensors of the F series pump have three leads. Faulty wiring may cause the proximity sensor to short circuit. Carry out the wiring carefully and accurately. • Connect the leads of proximity sensor A with te rminals 6, 7, and 8 respectively of the controller.
19 6 OPERATION Carry out the following preparatory steps when starting pump operation for the first time after installation or after a long suspension of the pump operation. 1. Confirm that all liquid connectors along the liquid piping s ystem are fastened tightly.
20 7 TROUBLESHOOTING TROUBLE CAUSES COUNTERMEASURES INSPECTION & CHECK POINTS Faulty operation of 4- way solenoid valve 1 Inspect and repair or rep lace. a Install qui ck e xhaust valves if damaged by corrosive gas Wrong wiring or disconnection in proximity sensor 1 Inspect and correct wiring.
21 TROUBLE CAUSES COUNTERMEASURES INSPECTION & CHECK POINTS Liquid leaks. Bellows are damaged. 1 Replace pum p head. a Check if s upply air pressure is within the specification. b Check if pump stroke speed is within the specification. c Check if liqu id temperature is .
デバイスRaymarine FA-2Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raymarine FA-2Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaymarine FA-2Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raymarine FA-2Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raymarine FA-2Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raymarine FA-2Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaymarine FA-2Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raymarine FA-2Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaymarine FA-2Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。