US-1 EBZ5150/RH U S OWNER 'S/ OPERA T OR'S MANUAL BA CKP A CK BLO WER 848-L3W-93A0 (909) W ARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
US-2 EBZ5150/RH SAFETY FIRST Instructions contained in warnings within this manual and warning seals marked with a symbol on the blower concern critical points which must be taken into consideration to prevent possible serious bodily injury, and for this reason you are requested to read all such instructions carefully and follow them without fail.
US-3 EBZ5150/RH U S 1. Parts location ■ MODEL EBZ5150/EBZ5150RH Dimensions (L x W x H) mm (in) EBZ5150 ·······································································································401x483x495 (15.
US-4 EBZ5150/RH For safe operation and maintenance, symbols are carved in relief on the machine. According to these indications, please be careful not to make a mistake.
US-5 EBZ5150/RH U S • The blower is used for blowing away leaves and other debris on the ground. When operating the blower, the operater must stand with both feet firmly on the ground. Do not operate the blower while standing on a ladder or a stand.
US-6 EBZ5150/RH 5. For safe operation 2. Before starting operation, always make sure to check if any obstacles are left inside the volute case and net. The obstacles may cause damage on fan and volute case and serious injury. 3. Check to see if the shock-absorbing rubber mount has become cracked or otherwise damaged.
US-7 EBZ5150/RH U S 5. For safe operation ordinances. 2. To reduce sound levels, limit the number of pieces of equipment used at any one time. 3. Operate power blowers at the lowest possible throttle speed to do the job. 4. Check your equipment before operation, especially the muffler, air intakes and air filters.
US-8 EBZ5150/RH 6. Set up ■ BLOWER TUBES 1. Connect the blower and swivel joint with flexible hose. Clamp both ends of the flexible hose securely with the hardware supplied with the unit. 2. Align the protrusion and the groove provided on the tube ends and twist the tube until connection is locked up.
US-9 EBZ5150/RH U S 7. Fuel lines or fuel tank of the engine. • Failures caused by operating engines on gasoline with octane rating lower than 89 are not covered by the RedMax Two- Stroke engine warranty.
US-10 EBZ5150/RH 7. Fuel test standard has been discontinued by API in 1995 and it no longer exists. • Gasoline/Oil mixture Storage Recommendations Store your gasoline or gasoline/oil mixture in a cool dry area in a tightly sealed approved container to limit the entry of moisture and additional air (oxygen).
US-11 EBZ5150/RH U S 8. Operation ■ CONTROL ARM [EBZ5150] (F5) •H old the upper end of the control arm in hand and, while pulling it away from the unit, rotate arm forward (anti- clockwise as the arrow direction) until it clicks. (The first position) And if you want, you can rotate arm more forward until it clicks.
■ STOPPING ENGINE [EBZ5150] •M ove the throttle lever to the idling position and press the stop switch (red button). The machine has the mechanism that once the stop button is pushed the plug won't give off sparks until the engine stops.
US-13 EBZ5150/RH U S Maintenance, replacement, or repair of the emission control device and systems may be performed by any non-road engine repair establishment or individual.
US-14 EBZ5150/RH held by three bolts (F23 (2)). (Fastening Torque : 8 to 12 N·m) • Also make sure that the speak arrester and the diffuser are properly attached with four bolts (F23 (1)). (Fastening Torque : 2 to 3 N·m) • Even if one of seven bolts is loose, it may result in engine catching on fire.
US-15 EBZ5150/RH U S 9. Maintenance ■ IGNITION COIL AIR GAP INSPECTION • If the gap is out of standard or when installing the coil or rotor, adjust the air gap between the ignition coil and the iron core of the rotor. Air Gap: 0.40mm (0.35 ~ 0.45mm) 0.
US-16 EBZ5150/RH BEFORE STORING THE BLOWER: 1. Drain a fuel tank and push the primer bulb until it becomes empty of fuel. 2 .Remove the spark plug and drop a spoonful of 2-cycle oil into the cylider. Crank the engine several time and install the spark plug.
US-17 EBZ5150/RH U S The EPA (U.S. Environmental Protection Agency), CARB (California Air Resources Board), Environment Canada and RedMax are pleased to explain the emissions control system's warranty on your 2009 and later small off-road engine.
US-18 EBZ5150/RH warranty is warranted for the remaining warranty period. Any warranted part that is scheduled only for regular inspection in the maintenance schedule will be warranted for a period of two years.
デバイスRedMax EBZ5150の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RedMax EBZ5150をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRedMax EBZ5150の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RedMax EBZ5150の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RedMax EBZ5150で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RedMax EBZ5150を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRedMax EBZ5150の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RedMax EBZ5150に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRedMax EBZ5150デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。