RenesasメーカーHS7047ECH61Hの使用説明書/サービス説明書
ページ先へ移動 of 26
2004.1.29 SH7047 Group FP-100 M User System Interfa ce Board HS7047ECH61H User’s Manual Renesas M icrocomput er Developm ent Enviro nment System SuperH TM Family /SH7047 S eries Rev.
Cautions Keep safety first in your circ uit designs! 1. Renesas Technology Corp. put s the maximum e ffort i nto making semi conductor pr oducts better and more reliable, but the re is always the possibility that trouble may occur with them. Trouble with semi conductors may l ead to personal i njury, fire or property dama ge.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufa ctured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e boards determined to be defe ctive in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have ot her rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
V W ARNING Observe the pr ecautions listed below. Failure to do so will result in a FIRE HA ZARD and will damag e the user system and the emula tor product or will r esult in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric shock pr evention and qualit y assurance.
i Preface The HS7047ECH61H is a u ser sys tem in terface board that conn ects a user s ystem for th e SH7047 FP-100M packag e to the SH7046 E6000H em ul ator (HS7046EPH60H).
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User System Interf ace Board to User System .
1 Section 1 Configuration Figure 1 and table 1 sh ow th e configu ration and com ponents of th e user system interf ace board for the FP-100M pack age. Please m ake su re you h ave all of t hese com ponents w hen unpacki ng. Socket cover Screws (M2.6 x 6 mm) with flat washers EV-chip board Board User system Spacer IC socket Screws (M2.
2 CAUTION Use an IC149-100- 054-B51 socket (manuf actured by YAMAICH I ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user syst em. Table 1 HS7047ECH61H Compon ents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Board to User S ystem W ARNING Always switch OFF th e user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
4 2.1.2 Installing Cable Hea d CAUTION Check the location of pin 1 before inserting. Alig n pin 1 on the IC s ocket for an FP-100M packag e on the u ser sy stem wit h pin 1 on the us er system interface board, an d insert the us er system interface board into th e IC socket on th e user system , as shown in figure 2.
5 Screws (M2.6 x 12 mm) with flat washers Pin 1 Board IC socket (IC 149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 2 Connecting User System Interface Board to User .
6 2.2 Connecting User System Interface Board to EV-Chip Board W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
7 Connector No. UCN1 UCN1 UCN2 UCN2 Board EV-Chip Board Connector No. Board Connector No. EV-chip board Spacer User system Figure 3 Connecting User System Interface Board to EV-Chip Board.
8 2.3 Recom m ended Dim ensions for User System M ount Pad ( Footprint ) Figure 4 show s the recom m ended dimen sions for the m ount pad (f ootprint) for the u ser system w ith an IC socket f or an FP-100M packag e (IC149-100- 054-B51: m anuf actured by YAMA ICHI ELECTRONICS C o.
9 2.4 Dim ensions for EV-Chip Boar d and User Syste m Inter face Board The dimens ions for the EV- chip board and the u ser system interf ace board are shown in figu re 5. 140.0 116.0 EV-chip board Unit: mm Tolerance: ±0.5 mm User system interface board 19.
10 2.5 Resultin g Dimensions after Con necting User System Interf ace Board The resulting dim ensions, af ter connecting th e user system interf ace board to the user sy stem, are shown in figure 6. Unit: mm Tolerance: ±1.0 mm User system EV-chip board IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co.
11 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
12 MCU (SH7047) Screws (M2.6 x 6 mm) with flat washers Socket cover Pin 1 User system IC socket (IC 149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co.
13 Section 4 Verifying Operation 1. Turn on the em ulator accordin g to the procedures described in the SH 7046 E6000H Emul ator User's Manual (HS 7046EPH60HE).
14 To use the crystal oscillator mounted on the EV-chip board Install a crystal oscillator into the crys tal oscillator terminals on the EV-chip board.
15 Section 5 Notice 1. Before connectin g any parts or cables, make su re that pin 1 on th e both sides are correctly aligned. 2. Do not apply excessive force to the u ser system interface board w hile it is con nected to the user system .
SH7047 Group FP-100M User System Interface Board HS7047ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
SH7047 Group F P-100M User Sy stem Inte rface B oard HS7047E C H61H U ser’ s Manual REJ10B0039-0400H.
デバイスRenesas HS7047ECH61Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas HS7047ECH61Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas HS7047ECH61Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas HS7047ECH61Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas HS7047ECH61Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas HS7047ECH61Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas HS7047ECH61Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas HS7047ECH61Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas HS7047ECH61Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。