This water heater must be installed an d servic ed by an authorised person. Please leave t his guide with the householder. “Streamline Closed Circuit” GAS BOOSTED SOLAR WATER HEATER OWNER’S MANUAL AND WARRANTY / INSTALLATION INFORMATION WARNING: Plumber – Be Aware Use copper pipe ONLY .
PATENTS This water heater may be protected by one or more patents or registered designs. ® Registered trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. ™ Trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. Notice to Victorian Customers from the Victorian Plumbing Industry Commission.
3 CONTENTS HOUSEHOLDER – We recommend you read pages 5 to 16. The other pages are intended for the installer but may be of interest. Introduction .......................................................................................................
4 INTRODUCTION Congratulations on choosing a “STREAMLINE CLOSED CIR CUIT GAS BOOSTED” solar water heater. We are confident that your pur chase will provide you many years of trouble free hot water. All over the world, the Solahart name is synon ymous with quality in wa ter heating.
5 ABOUT YOUR WATER HEATER MODEL TYPE Congratulations for choosing a Solahart ® water heater. Your Solahart Streamline closed circuit solar water heater is designed for the solar collectors to be roof mounted and the solar storage tank to be installed at ground or floor level.
ABOUT YOUR WATER HEATER 6 SAFETY This water heater is supplied wi th temperature sensor s, a FlameSafe™ prot ection system, pressure relief valves and a combination temperature pressure reli ef valve. These devices must not be tampered with or removed.
ABOUT YOUR WATER HEATER 7 TO TURN ON THE WATER HEATER • Screw in the drain pl ugs at the cold water inlet a nd hot water outlet of the gas booster if the gas booster has been drained. • Open the cold water isolation valve fu lly at the inlet to the water heater.
ABOUT YOUR WATER HEATER 8 DOES THE WATER QUALITY AFFECT THE WATER HEATER? The water heater is suitable for most public wate r supplies, however some water q ualities may have detrimental effects on the cylinder, ga s booster heat excha nger and fittings.
ABOUT YOUR WATER HEATER 9 DRAINING THE GAS BOOSTER WATER HEATER • Turn off the water heater (refer to “Turn Off The Water Heater” on page 6). • Open a hot tap (preferably the shower outlet). • Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of the water heater.
10 HOW YOUR WATER HEATER WORKS SOLAR OPERATION The Solahart Streamline closed circuit solar water he ater has its vitreous enamel lined solar storage tank installed at ground or floor level, remotely from the solar collectors. This water heater is an indirect solar hot water system with a heat exchanger in the solar storage tank.
HOW YOUR WATER HEATER WORKS 11 MAINS PRESSURE The water heater is designed to op erate at mains pressure by connec ting directly to the mains water supply. If the mains supply pressu re in your area exceeds that shown on page 19, a pr essure limiting valve must be fitted.
12 REGULAR CARE TEMPERATURE PRESSURE RELIEF VALVE This valve is near the top of the wa ter heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approxim ately 1/50 of its volume.
13 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending t o any condition or fault that is not related to manufacture or failure of a part. COLD WATER FROM THE HOT TAP • Close the hot tap, wait 10 seconds and open the hot tap again.
SAVE A SERVICE CALL 14 • Are you using more hot water than y ou think? Is one outlet (especially the shower) us ing more hot water than you think? Very often it is not realised the amou nt of hot water used, particu larly when showering. Carefully review the family’s hot water usage.
SAVE A SERVICE CALL 15 TEMPERATURE PRESSURE RELIEF VALVE RUNNING • Normal Operation It is normal and desirable this valve allows a small quantity of water to escape during the heat ing cycle. However, if it discharges more than a bucket full of water in 24 hours, there may be another problem.
SAVE A SERVICE CALL 16 CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL During the heating cycle, it is not unusual to see water vapour clouds steaming from the flue terminal, particularly on cold da ys. This is normal operation of the gas booster.
17 INSTALLATION – SOLAR STORAGE TANK THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available. (refer to the rating label on the water heater) The system is suitable for installation with Solahart ‘J’ or ‘KF’ solar collectors.
INSTALLATION – SOLAR STORAGE TANK 18 The top of the solar storage tank must be a mi nimum of 500 mm below the bottom of the solar collectors for the system to operate correctly. As a guide the following requirements extracted from the Australian Gas Installations Standard AS 5601, must be observed.
INSTALLATION – SOLAR STORAGE TANK 19 MAINS WATER SUPPLY Where the mains water supply pressure e xceeds that shown in the table below, an appr oved pressure limiting valve is required and should be fitt ed as shown in the installation diagram (refer to diagram on page 29 ) .
INSTALLATION – SOLAR STORAGE TANK 20 RAIN WATER TANK If the solar collectors and solar pipe work are to b e inst alled on a section of roof which is part of a rain water runoff collection system, then it is recommended this section of roof and its gutter be isolated from the rain water collection system.
INSTALLATION – SOLAR STORAGE TANK 21 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. This water heater ha s both a hot water outlet connection and a tempered wate r outlet connection.
INSTALLATION – SOLAR STORAGE TANK 22 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A solar water heater should not be installed as part of a circulated hot water flow and return system in a building. The benefits of solar gain will be signifi cantly reduced and energy gained from the sun lost through the pipe work.
INSTALLATION – SOLAR STORAGE TANK 23 REDUCING HEAT LOSSES The cold water line to and the temp ered water and hot water lines from the wate r heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed.
INSTALLATION – SOLAR STORAGE TANK 24 DIMENSIONS AND TECHNICAL DATA Model DBV 270 Capacity 270 litres Mass 165 kg (empty) 435 kg (full) Test Point Gas Pressure (kPa) Gas Booster Details Gas Booster Model Delivery 25°C rise (litres / min) Hourly Gas Consumption (MJ) Min.
INSTALLATION – SOLAR STORAGE TANK 25 TYPICAL INSTALLATION – OUTDOOR LOCATION.
26 INSTALLATION – SOLAR COLLECTORS SOLAR COLLECTOR LOCATION Consideration must be given to the position of the solar collectors in relation to the solar storage tan k. There are limitations on both t he maximum length of the solar hot and solar cold pipes and the maximum height between the solar storage tank and the solar collectors.
INSTALLATION – SOLAR COLLECTORS 27 PIPE LENGTHS The solar hot and solar cold pipes between the so lar storage tank and the solar collectors shall: • be of DN15 hard drawn c opper pipe. • have a continuous fall from the solar collector s to the solar storage tank of a minimum 5 ° (1 in 10 grade).
INSTALLATION – SOLAR COLLECTORS 28 WARNING: Plumber – Be Aware • The solar hot and solar cold pipes between th e solar storage tank and the solar collectors MUST BE of copper and fully insulated with closed cell polymer insulation or similar (minimum thickness 13 mm).
29 CONNECTIONS – PLUMBING CONNECTION SIZES • Hot water connection: RP¾/20. • Cold water connection: RP¾/20. • Tempered water connection: RP¾/20 • Solar hot (from collector) connec tion: DN15 compression fitting. • Solar cold (to collector) c onnection: DN15 compression fitting.
CONNECTIONS – PLUMBING 30 This solar storage tank has either a plastic dip tube or fitting liner in the inlet and out let fittings (see diagram). These must be in place for the water heater to function properly. Do not remove or damage them by using hea t nearby.
CONNECTIONS – PLUMBING 31 In locations where water pipes are pr one to freezing, the drain line must be insulated a nd not exceed 300 mm in length. In this instance, the drain line is to discharge into a tundish throug h an air gap of between 75 mm and 150 mm.
CONNECTIONS – PLUMBING 32 To connect the solar cold and solar ho t pipes to the solar storage tank: • Remove the compression nut and olive from eac h of the solar cold outlet and solar hot inlet fittings at the top of the solar storage tank. Remove the rubber washer from each of the unio ns and discard.
33 CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled wit h wa te r. MEGGER READING It is not mandatory to conduct a megge r test on a plug in appliance, however if a megger test is conducted on this water heater, t hen the following should be noted.
CONNECTIONS – ELECTRICAL 34 HOT SENSOR LEAD House the hot sensor lead at the water heater in the flexible c onduit provided and secure the conduit in the cut out on the tab located behind the upper front cover. Connect the hot sensor c able to the hot sensor cable connector located on th e tab behind t he upper front cover.
35 COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the solar storage tank and solar control unit must not be switched on until the water heater is filled with water . • Open all of the hot water taps in the house (don’t forget the shower).
COMMISSIONING 36 SOLAR CIRCUIT It is necessary to commission and check the operation of the solar circuit. The commissioning procedure includes: • checking the circulation of closed ci rcuit fluid through the solar circuit. • checking the drain back function of the solar circuit.
COMMISSIONING 37 Warning: Although non-toxic, the following first aid advice and procedures should be followed if the closed circuit fluid concentrate come s into human contact or is spilt: • Swallowed - give milk or wate r and seek medical attention.
COMMISSIONING 38 Commissioning the Solar Circuit To commission and check the solar circuit: 1. Switch off the electrical supply at the power outlet to the solar storage tank. If the pump has been operating, wait five minutes to allow the drain back of the closed circuit fluid in the solar circuit.
COMMISSIONING 39 6. Open the heat exchanger drain valve and remove the plug from the end of the hose. The closed circuit fluid will flood the hose to the static level of the closed circuit fluid inside of the heat exchanger. 7. Mark the static level of the closed circuit fluid on the side of the solar storage t ank with a non permanent marker.
COMMISSIONING 40 10. Check the closed circuit fluid is circulating around the solar circuit. To check circulation: Listen for the trickling sound of the closed circuit fluid returni ng into the heat exchanger by placing your ear against the side towa rd the top of the solar storage tank.
COMMISSIONING 41 Drain Back Function 13. Switch off the electrical supply at the power outlet to the solar storage tank. The pump will deactivate. The closed circuit fluid will drain back down to the heat exchanger and the l eve l of the closed circuit fluid in the clear hose will rise.
COMMISSIONING 42 Closed Circuit Fluid Level 15. Measure the distance from t he text marking “MINIMUM FLUID LEVEL WITH PUMP OPERATING” to the closed circuit fluid dynam ic level marked on the side of the solar storage tank during step 11.
COMMISSIONING 43 16. Determine the correct amount of water to be added to or closed circuit fluid to be drained from the heat exchanger if the dy namic level is either bel ow the te xt marking “MINIMUM FLUID LEVEL WITH PUMP OPERATING” or mo re than 150 mm above this mark.
COMMISSIONING 44 17. Add water to top up the level of the closed circuit fluid in the heat exchanger if required. To add water to the closed circuit fluid: If not already removed, disconnect the d.
COMMISSIONING 45 Pressure Testing the Solar Circuit 20. Close the heat ex changer drain valve. 21. Refit the solar circuit relie f valve, orientating the valve outlet to the rear of the solar storage tank. Secure with the spring clip. Reconnect the drain pipe to the valve.
COMMISSIONING 46 Remove Closed Circuit Fluid Level Hose 28. Remove the clear hose from the solar storage tank when satisfied the commissioning procedure is complete.
COMMISSIONING 47 DIAGNOSTIC FEATURES OF THE SOLAR CONTROLLER The solar storage tank incorporates an electronic so lar control module. This is located inside of the lower front cover and houses both a green and a red LE D. The LEDs emit either a constant glow or a series of flashes with a 2 second interval bet w een flashes.
COMMISSIONING 48 GAS INLET PRESSURE IMPORTANT - CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the pre mises operating (burners alight). The minimum gas supply pressure is: Natural Gas 1.
COMMISSIONING 49 Minimum test point gas pressure Refer to the rating label on the water heater for the minimum test point gas pressure. 1. Open a hot tap slowly until the burners ignite. 2. Press and hold down the MIN button (“1L” is shown on the LED display), and observe the reading on the manometer.
COMMISSIONING 50 Maximum test point gas pressure Refer to the rating label on the water heater for the maximum test point gas pressure. Follow Steps 1 to 7 of the “Minim um test point gas pressure” proc edure, but open the ho t tap fully and use the MAX button inste ad of the MIN button.
51 DRAINING THE WATER HEATER To drain the water heater: Gas Booster Water Heater • Turn off the water heater (refer to “To Turn Off The Water Heater” on page 50). • Open a hot tap (preferably the shower outlet). • Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of the gas booster.
52 WATER SUPPLIES Your water heater is manufactured to suit the water conditions of mo st Australian metropolitan supplies. However, there are some known w ater supplies which can have detrimental effects on the water heater and its operation and/or life expectanc y.
53 SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY WARRANTY CONDITIONS 1. This warranty is applicable only t o water heaters manufactured from 1 st July 2006.
SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY 54 WARRANTY Solahart* will: a) Repair or, if necessary replace any Solahart water heater; or b) Replace any com.
55 SOLAHART INSTALLATION AND WARRANTY REPORT Dear Customer – To register your warranty please ensure the following information is correct then sign and return to our Solahart Industries Pty Ltd freepost address: Solahart Industries Pty Ltd.
56 SOLAHART OFFICES Corporate Headquarters 112 Pilbara St Welshpool Western Australia 6106 Postal Address: PO Box 95 State Parcel Centre Welshpool WA 6986 Telephone International: + 61 8 9351 4600 Facsimile International: + 61 8 9351 4698 Email: solahart@solahart.
デバイスRheem GAS BOOSTED SOLAR WATER HEATERの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rheem GAS BOOSTED SOLAR WATER HEATERをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRheem GAS BOOSTED SOLAR WATER HEATERの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rheem GAS BOOSTED SOLAR WATER HEATERの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rheem GAS BOOSTED SOLAR WATER HEATERで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rheem GAS BOOSTED SOLAR WATER HEATERを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRheem GAS BOOSTED SOLAR WATER HEATERの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rheem GAS BOOSTED SOLAR WATER HEATERに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRheem GAS BOOSTED SOLAR WATER HEATERデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。