RheemメーカーRUTG-66DVの使用説明書/サービス説明書
ページ先へ移動 of 36
Direct V ent Wa ter Heater AP14558 (01/08) ! FOR YOUR SAFETY! — Do not store or use gasoline or other flamm able vapors or liquids or other com bus tib le ma ter ial s in the vicinity of this or any other appliance. T o do so may result in an explosion or fire.
Safety Information Safety Precautions ....... 3–6 LP Gas Models ........... 5 Installation Instructions Location .................. 7 Inspect Shipment ........... 8 V enting ............... 9-14 W ater Connections .... 15, 16 Relief V alve .........
Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater . It may save you time and money . Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death.
Time/T emperature Relationship in Scalds W ater T emperature Time T o Produce a Serious Burn 120°F (49°C) More than 5 minutes 125°F (52°C) 1 1 / 2 to 2 minutes 130°F (54°C) About 30 seconds 135.
5 Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant.
6 IMPOR T ANT SAFETY INFORMA TION R E A D A L L I N S T R U C T I O N S B E F O R E U S I N G . ! W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury or loss of life.
1” (2.5 cm) min 1” (2.5 cm) min 1” (2.5 cm) min Coaxial V ent Pipe & Air Intake ! W ARNING: Follow vent manufacturer’ s instruction while installing vent. If requir ed, provide additional clearances from vent to combustibles per vent manufacturer’ s instruction.
Installing the water heater: Corr osive Atmospheres The air in beauty shops, dry cleaning establishments, photo processing labs, and storage areas for liquid and powdered bleaches or swimming pool chemicals often contains such halogenated hydrocarbons.
The water heater must be installed with a 3”/5” diameter UL approved Category III Coaxial Stainless Steel appliance coaxial vent pipe and an appropriate adapter . V enting The installation of venting must comply with national codes, local codes and the vent manufacturer ’ s instructions.
Installing the water heater: V enting Thr ough Closed Spaces If the coaxial vent piping passes through a closed space, a minimum clearance of 1” (2.5 cm) when installed horizontally or 6” (15 cm) when installed vertically should be maintained between the coaxial vent pipe and combustibles and noncombustibles.
D V V E F IX ED CL OS ED O P ERA BL E O PE R A BL E FIXE D CL OS ED v v B L F C B v v v X B B B A J B I H X v M K v G A The following information should be used for determining the proper location of the vent terminal for direct vent tankless water heaters.
Installing the water heater: Additional Considerations Do NOT install vent terminal under any patio or deck. T o help prevent moisture from freezing on walls and under eaves, do not locate vent terminal on the side of a build ing with prevailing winter winds.
Example A: T ypical Horizontal T ermination w/ 7/8” per foot DOWNW ARD Slope 13 Installing the water heater: 94° Elbow Out e r W a l l Inn er W a ll Pl at e W a te r Hea ter Out side W a ll Sid e V.
Installing the water heater: V ertical V ent Installation A fire stop plate should be installed at every penetration of a floor or ceiling if the vent is not running in a fire-rated shaft. Maintain the recommended air space clearance to combustible materials and building insulation.
15 W ater Supply Connections IMPOR T ANT : Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater . Any heat applied to the water supply fittings will permanently damage the internal components of the water heater .
Installing the water heater: W ater Supply Connections, continued Notice: If the water flow resistance of a shower head is too high, the burner in the water heater will fail to ignite. Keep the shower head clean from debris that could cause additional pressure drop.
Relief V alve A new pr essu r e r el ief val ve , co mpl yi ng with the Standard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22/ CSA 4.4, must be installed at the hot water outlet connection of the water heater at the time of installation.
This water heater is certified for installations up to 3,280 feet (1000 m) above sea level. The input rating of this water heater is based on sea level operation. At higher elevations, the actual input rate may be lower than the value listed on the rating label.
Remote Control Installation One (1) remo te con tro l is prov ided with th e water heater . Additional remote controls may be purchased separately . Up to three (3) remote controls can be used with this water heater .
20 Installing the Main Remote Control: W ARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFP A 70, or in Canada, Canadian Electrical Code, CSA C22.
Electrical Connection POWER CORD: ● The electric power supply requirement for this water heater is 120 V AC/60HZ, 2 Amps. ● The water heater comes with a three (3) pin power supply cord. Use only a power outlet with a ground terminal. ● The installation of an GFCI (Ground Fault Circuit Interrupter) is recommended.
22 Installing the water heater: T ypical Installation of W ater Heater (V enting Required) W all Plate Outside W all Outside W all With Protective V ent T ermination Screen 94° Elbow V ent Adapter Po.
23 For increased energy efficiency , use pipe insulation. Please install the insulation according to the diagram above, making sure to insulate all the way to the top. Do not cover any drain or pressure relief valve(s). Do’ s ❑ Do follow all installation instructions covered in this manual.
Installing the water heater: A. Indoor W ater Heater Location ❑ Close to area of vent termination. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed. ❑ Sufficient fresh air supply for proper operation of water heater .
25 Lighting the water heater: Before operating this water heater , be sure to read and follow the instructions on the label pictured below and all other labels on the water heater , as well as the warnings printed in this manual.
T ime/T emperatur e Relationship in Scalds W ater T emperature T ime T o Produce a Serious Burn 120°F (49°C) More than 5 minutes 125°F (52°C) 1 1 / 2 to 2 minutes 130°F (54°C) About 30 seconds 1.
27 W ater T emperature Setting… Maximum water temperature occurs while the burner is on. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. W ater temperature at the faucet may vary depending on season and length of pipe from the water heater .
Car e and cleaning of the water heater: Housekeeping Before performing Housekeeping tasks to this water heater , turn the unit off and disconnect the power supply .
! CAUTION: Do not operate without the condensate trap connected to the vent and routed to the proper drain. 29 Condensate T rap Inspection On a regular basis, inspect the condensate trap to ensure there is enough water in the trap and the condensate is draining properly .
Draining the W ater Heater Below are instructions for draining water out of the water heater . Turn off the switch on the remote control. Close the gas shut-off valve(s). Unplug the power supply cord (or disconnect breaker) at least 10 seconds after step #1.
31 Befor e Y ou Call For Service… T roubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for service. CAUTION: For your safety , DO NOT attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors or other safety devices.
Hot W ater Outlet Err or Code Guide: When an error code is displayed: ● Close the hot water faucet, turn off the switch on the remote control. ● W ait for about 5 minutes before turning the switch on again.
33 Replacement Parts: Direct V ent W ater Heater Instructions For Placing a Parts Order Address parts orders to the distributor or store where the water heater was purchased. All parts orders should include: The model and serial number of the water heater from the rating plate.
Required adjustment for up to 140°F (60°C) water temperature settings ! W ARNING: Refer to scald potential warnings on page 4 before making adjustment. Changing this setting is done at your own risk. DO NOT execute the following adjustment if the setting of up to 140°F (60°C) is not requir ed.
35 The content on this page is intended for use by qualified installation/service personnel ONL Y . W ARNING: Improper adjustment, altera- tion, service or maintenance can cause pr op- erty damage, personal injury , or death.
36 IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or ro ut ine ma in te nan ce , it is su gg es te d th at yo u f ir st co nt act yo ur in st all er , pl um bi ng c on tr act or or previously agreed upon service agency .
デバイスRheem RUTG-66DVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rheem RUTG-66DVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRheem RUTG-66DVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rheem RUTG-66DVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rheem RUTG-66DVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rheem RUTG-66DVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRheem RUTG-66DVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rheem RUTG-66DVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRheem RUTG-66DVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。