W ARNING C onversion Manual f or the RHFE-263F A Ⅱ Energysaver Gas Direct V ent W a ll Furnace This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction.
2 Rinnai Corporation RHFE-263F A Ⅱ Conversion Manual Safety Symbols High Altitude Installation T echnical Data This is the safety al ert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury .
3 Rinnai Corporasion RHFE-263F A Ⅱ Conversion Manual Manifold screw locations Conversion Procedure The gas supply shall be shut of f prior to disconnecting the electrical power , before proceeding with the conversion.
4 Rinnai Corporation RHFE-263F A Ⅱ Conversion Manual Adjust Gas Pressure Settings 1. T urn off the gas and the power supply . 2. Hold both ends of the bottom cover (undercover assembly) and pull toward you to remove the cover . Cover snaps in place.
5 Rinnai Corporasion RHFE-263F A Ⅱ Conversion Manual Adjust Gas Pressure Settings The LED display turns blank and the unit returns to the normal off mode. While programming the correct low fire and high fire gas pressure settings, do not adjust gas pressure on this appliance using the screw on top of the gas valve.
6 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion A VERTISSEMENT A VERTISSEMENT Manuel de Conversion pour RHFE-263F A Ⅱ Chauf fage au gaz à ventilation directe avec économiseur d’énergie .
7 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion Haute Altitude Installation Données T echniques La conversion de l'appareil pour l'opération aux hautes altitudes (> 2000 ft, 610.
8 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion A TTENTION Les emplacements divers de vis Procédure de Conversion Avant d’ef fectuer la conversion, couper d’abord l’alimentation en gaz, ensuite, couper l’alimentation électrique.
9 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion Ajustage et Reglage de la Presion de Gas 1. Eteindre le gaz et le pouvoir fournit. 2. T enir les deux fins de la couverture inférieure (l'assemblée clandestine) et la force vers vous enlever la couverture.
10 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion 10 Ajustage et Reglage de la Presion de Gas Le vide MENE de virages d'exposition et l'unité retournent au normal du mode.
11 Rinnai Société RHFE-263F A Ⅱ Manuel de conversion 11 Parts List(LP Gas to Natural Gas) Kit 308F-2070-5 Liste des Pièces (du gaz propane au gaz naturel) Parts List (Natural Gas to LP Gas) Kit 308F-2070-6 Liste des Pièces (du gaz naturel au gaz propane) Part Name (Nom de la Pièce) Part No.
308F-2073 (00) Printed in Japan 2006.10 1 0 3 International Drive, Peachtree City, Georgia 3 0 2 6 9 Phone:1 - 8 0 0 - 6 2 1 - 9 4 1 9 Fax:1 - 8 8 .
デバイスRinnai RHFE-263FA IIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rinnai RHFE-263FA IIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRinnai RHFE-263FA IIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rinnai RHFE-263FA IIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rinnai RHFE-263FA IIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rinnai RHFE-263FA IIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRinnai RHFE-263FA IIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rinnai RHFE-263FA IIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRinnai RHFE-263FA IIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。