Released 9-1 1-98. Rev . A - Change Power station to charging stand pg. 3. 9-16-98 Rev . B - Change battery type from ni-cad to rechargeable pg. 3,4 9-16-98 Rev .
Model FR-214 CTCSS Privacy Code System active ON AIR T ransmit mode active BUSY Signal being received BA T LOW Low battery voltage warning SCAN Channel Scan in progress C H Current channel LOCK Tranci.
128-5379C 3 of 12 2 Powering the transceiver: Y our FR-214 radio transceiver kit includes three rechargeable AA batteries (RBP-214) and a charging station. Y ou may operate your FR-214 using the rechargable batteries included or you may use alkaline batteries.
Charging the RBP-214 batteries: Insert the charging adapter into a household electrical outlet and connect its power jack to the socket at the lower rear corner of the charging stand. Simply placing the radio into the charging stand will begin the charging process.
UP and DOWN Buttons: If these buttons are pressed before pressing the Lock/function button, a single press will display the current volume setting and subsequent presses will change the volume setting up or down. Important: If a speaker/microphone or earphone is used, check the volume setting before connecting it to the earphone jack.
Setting the channel: Press the Function/lock Button once The channel number will flash on the display , indicated by “CH_xx.” Pressing the up or down buttons, momentarily , within five seconds will increment or decrement through the 14 channels one at a time.
The display will show “Ctxxx”, indicating the status of the CTCSS mode as being on or off. Pressing the up or down buttons, within 5 seconds will turn the CTCSS mode on or off.
Scrolling to the beginning of the function setting mode Press the Function/lock button six times The channel number will flash on the display , beginning the function selection sequence again. If the conformation beeps are on, a double tone will be heard.
T roubleshooting Problem Possible cause Correction No transmission Weak batteries Charge or replace batteries while pressing Incorrect battery Install the batteries in the the PTT button Polarity directions indicated by the battery tray .
T echnical Specifications: General Frequency Range 462 - 467 MHz Channels 14 Privacy Codes 38 Modulation T ype FM ± 2.5 KHz Power Supply 3 - 4.5VDC Receiver Sensitivity at 12dB Sinad .
Continuous T one Coded Squelch System T one Frequencies CTCSS Fre q. Hz CTCSS Fre q. H z 1 67.0 20 131.8 2 71.9 21 136.5 3 74.4 22 141.3 4 77.0 23 146.2 5 79.7 24 151.4 6 82.5 25 156.7 7 85.4 26 162.2 8 88.5 27 167.9 9 91.5 28 173.8 10 94.8 29 179.9 1 1 97.
128-5379C 12 of 12 Applies to Audiovox Family Radio Service Products. AUDIOVOX CORPORATION (the Company) warrants to the original retail purchaser of this product that should this product or any part .
デバイスAudiovox FR214Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Audiovox FR214Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAudiovox FR214Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Audiovox FR214Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Audiovox FR214Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Audiovox FR214Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAudiovox FR214Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Audiovox FR214Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAudiovox FR214Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。