RuggedComメーカーI800の使用説明書/サービス説明書
ページ先へ移動 of 21
R uggedSwitch ™ i 800 F amily Installa tion Guide www.ruggedcom.com.
Copyright COPYRIGHT © 2008 RuggedCom Inc. ALL RIGHTS RESERVED Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registratio n.
Federal Communications Commission Radio Frequency Interference S t atement This equipment has be en tested and found t o comply with the limits for a Cla ss A digital devic e pursuant to Part 15 of the FCC Rules.
Table of Contents T able of Content s Federal Communications Commission Radio Frequency Interference Statement .. 3 Table of Contents ............................................................................................................ 4 Table of Figures .
Product Overview 1 Product Overview 1.1 Functional Overview The RuggedSwitch™ i 800, or i -Series, is a family of compact, fully managed Ethernet switches designed to operate reliably in harsh industrial environments.
Product Overview 1.3 i 800 Family Front Panel View Figure 1: Front Panel The front panel shown is representative of the i 800 family. Note that there are several Ethernet options available in several models, outlined in Section 1.
Product Overview 1.3.1 Front Panel LEDs ITEM Color Activity Comments Power status Green Solid Power On Alarm status Red Solid Alarm condition exists Blinking Link Established Fiber port status Yellow .
Product Overview 1.4 i 800 Family Top Panel View Figure 2: Top Panel For details on connecting the power supplies an d Ground, see Section 2.2 . For details on connecting the Fail-Safe Relay, see Section 2.
Product Overview 1.5 i 800 Family Bottom Panel View Ports 5-7, 7&8, or 9: Ports 1 – 4/6/8: 10/100/1000Base Tx, 100FX, 1000SX/LX 10/100Base Tx Figure 3: Bottom Panel For details on connecting the console port, see Section 2.4 . For a description of the memory slot, see Section 2.
Installation 2 Inst allation 2.1 DIN Rail Mounting The i 800 family of switches comes with a standard DIN rail mounting bracket. Figure 4 details the mounting configuration for a standard 1” DIN Rail.
Installation 2.2 Power Supply Wiring and Grounding Ratings : 12 - 24V , , 2A P1+ P1- GND P2- P2+ back front DC In p ut 1 DC In p ut 2 Chassis Ground Figure 5: DC Power supply and ground connec tions T.
Installation Figure 6 illustrates the connections required for both single and dual power supply configurations: Ratings : 12-24V , , 2A Figure 6: Power Supply Wiring Examples NOTES: • Connect to the DC inputs according to the polarity markings on the unit.
Installation 2.3 Failsafe Output Wiring The Failsafe output relay is provided via a Phoenix connector to signal critical error conditions that may occur on the unit. The contacts are en ergized upon power up of the unit and remain energized until a critical alarm condition or power loss occur s.
Installation 2.4 RS232 Console Port Wiring The RS232 Console Port is used for initially configuring the unit. The connection is made using a DB9-Female to RJ45 console cable with the pin-outs listed in Table 5 .
Installation 2.5 RJ45 Ports – Signal Description 10/100Base-TX ports allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground on the unit and can accept CAT-5 shielded twisted-pair (STP) cables.
Installation 2.6 Memory Slot The i 800 family of switches feature a remov able microSD memory module to support the following features: • Configuration update and backup • Redundant firmware image.
Technical Specifications 3 T echnical Specifications 3.1 Type Test Specifications IEC 61000-6-2 EMC: Generic Stand ards - Immunity for industrial environments Test Description Levels Enclosure Contact.
Technical Specifications 3.2 Environmental Specifications Parameter Range Comments Ambient Operating Tempera ture -20 to 60 ° C -40 to 85 ° C (Optional) Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
Technical Specifications 3.5 RJ45 Ethernet Port Specifications Data Port Medi a Distance Connector Type 10/100 Mbps CAT-5 UTP or STP 100m RJ45 Table 13: RJ45 Ethernet Port Specific ations 3.6 Fiber Optic Port Specifications Order Code Speed Standard Mode / Connecto r Tx (nm) Cable Type (um) _FG01 1000SX MM/LC 850 62.
Technical Specifications 3.7 Physical Dimensions Power 1 Power 2 i 802 CONSOLE 57600-N-8-1 MEMORY SLOT 4.625 2.225 3.750 3.918 5.296 0.460 3.050 0.246 0.833 3.833 4.421 3 1 4 2 56 7 8 Alarm R 3.490 3.918 NOTE: All dimensions are in inches. Figure 10: Mechanical Specifications Parameter Value Comments Dimensions 4.
Warranty RuggedSwitch™ i 800 family 21 RuggedCom® 3.8 Agency Approvals Agency Standards Comments Status ATEX Zone 2 Gas, Vapor, or Du st environmental Pending FCC FCC Part 15, Class A Emissions App.
デバイスRuggedCom I800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RuggedCom I800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRuggedCom I800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RuggedCom I800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RuggedCom I800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RuggedCom I800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRuggedCom I800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RuggedCom I800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRuggedCom I800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。