RuggedCom Inc. I 30 W hitmore Road, W oodbr idge, Ontario, C anada L4L 7Z4 Tel: (905) 856-528 8 I Fax: (905) 8 56-1995 I Toll Free: (888) 264-0006 Rugg ed Rugg ed Rugg ed Rugg edWir eless Wirele ss Wirele ss Wirele ss R R R R S S S S 900 900 900 900 W W W W Family Famil y Famil y Famil y Installatio n Guide www.
2 2008 Rugge dCom Inc . All rights reserv ed Rev103 Federal Communications Commission Radio Frequency Interference Statement This equipmen t has been tested and found to comply with the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2008 Rugge dCom Inc . All rights reserv ed Rev103 Table of Contents 1 Product Overview .................................................................................................................. 4 1.1 Functional Overview .................
4 2008 Rugge dCom Inc . All rights reserv ed Rev103 1 Product Overview 1.1 Functional Overview The RuggedWireless RS9 00W family of products are indu strially hardened, fully managed, IEEE 802.
5 2008 Rugge dCom Inc . All rights reserv ed Rev103 1.3 RS900W Family Front Panel View Figure 1 - Front Panel Des cription ITEM Activity Comments Solid Link Established LINK LED (Yello w) Blinking.
6 2008 Rugge dCom Inc . All rights reserv ed Rev103 1.4 RS900W Family Bottom Panel View Figure 2 - Bottom Pan el Description Chassis ground Power Supply Connection Optional DIN Rai l Mounting Brac.
7 2008 Rugge dCom Inc . All rights reserv ed Rev103 2 Inst al lation 2.1 DIN Rail Mounting An optional DIN ra il mounting bracket is available for the RS90 0W.
8 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.2 Power Supply Wiring and Ground ing 2.2.1 AC Pow er Suppl y Wiring and Gro unding Figure 4 - Power Supply Inp uts The AC powe r supply inputs should be connected as foll ows: 1. +/L should be connected to AC Line/Hot.
9 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.2.2 DC Pow er Suppl y Wiring and Gro unding Figure 5 - DC Power supply wi ring and grounding di agram The low vo ltage DC power supply features reve rse polarity protection and dual indep endent inputs.
10 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.3 Dielectric Strength (HIPOT) Testing Units which a re to have dielectric strength testing (HIPOT te sting) done in the field must ha ve the braided ground cable disconnected during the test.
11 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.4 Failsafe Output Wiring and Specific ations The Failsafe output relay is provided to signal critical error conditions that may occur on the unit. The contact s are energized upon power up of the un it and remain energized until an alarm condition or powe r loss occurs.
12 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.5 RS232 Port Wiring The RS232 po rt is used for configuring the unit. A stra ight-through serial cable with a DB-9 connector is re quired. There is no need to crossover the Transmit and Receive signals f rom the PC side since this has been done internally as is shown below.
13 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.6 RJ45 Ports – Signal Description Units with 10/100 Base-TX ports allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) ca ble with RJ45 male conne ctors.
14 2008 Rugge dCom Inc . All rights reserv ed Rev103 3 T echnical Speci fications 3.1 Operating Environment Parameter Range Commen ts Ambient Operat ing Temperatu re -40 to 85 ° C Ambient Temp erature as me asured from a 30 cm radius surrounding the center of th e enclosure.
15 2008 Rugge dCom Inc . All rights reserv ed Rev103 Isolation Comments 1500 V rms Dielectric test vo ltage (1 minute) between coil & contacts Table 7 - Failsafe Rela y Isolation 3.
16 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.5 Wireless Standards Supported Standard Parameter Mode Notes IEEE 802.11g 54 Mbps (WLAN) Full Access Point 2.4 Ghz ISM IEEE 802.11b 11 Mbps (WLAN) Client support Backwards compat ibility IEEE 802.
17 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.7 IEEE 802.11b/g The channe l identifiers, channel c enter freq uencies, and regu latory domains of e ach IEEE 802.
18 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.8 Fiber Optical Port Specifications Order Code Speed Standard Mode / Connect or Tx (nm) Cable Type (um) Tx min (dBm) Tx max (dBm) Rx Sensitivity (dBm) Rx Saturation (dBm) Typical Distance (km) Power Budget (dB) MJ 100FX MM/MT RJ 1300 50/125 -22.
19 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.9 Physical Dimensions Figure 10 - Mechanica l Specifications.
20 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.10 Agency Approvals Agency Standards Commen ts CSA CSA C22.2 No. 60 950, UL 6095 0 Approved CE EN 60950, EN 61000-6-2 CE Compliance is claime.
21 2008 Rugge dCom Inc . All rights reserv ed Rev103 5 Appendix A - Rugge dWireless ™ Fre quentl y Asked Questions ( F A Q) What factors c an affect wireless coverage/range? Range e stimates are typ ical a nd require line of sight.
22 2008 Rugge dCom Inc . All rights reserv ed Rev103 dBm Watts dBm Watts dBm Watts 0 1.0 mW 16 40 mW 32 1.6 W 1 1.3 mW 17 50 mW 33 2.0 W 2 1.6 mW 18 63 mW 34 2.5 W 3 2.0 mW 19 79 mW 35 3.2 W 4 2.5 mW 20 100 mW 3 6 4.0 W 5 3.2 mW 21 126 mW 3 7 5.0 W 6 4 mW 2 2 158 mW 38 6.
デバイスRuggedCom RS900Wの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RuggedCom RS900Wをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRuggedCom RS900Wの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RuggedCom RS900Wの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RuggedCom RS900Wで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RuggedCom RS900Wを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRuggedCom RS900Wの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RuggedCom RS900Wに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRuggedCom RS900Wデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。