RuggedSwitch ® RSG2100P Modular Power over Ethernet Managed Ethernet Switch Installation Guide August 14, 2008 www.ruggedcom.com RuggedCom Inc. I 30 Whitmore Road, Woodbridg e, Ontario, Canada L4L 7Z.
Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
T able of Content s 1 ...................................................................................................................... 4 Table of Figures 2 .........................................................................................
1 T able of Figures Figure 1: RSG2000 Series LED Display Panel ................................................................................ 8 Figure 2: RSG2000 Series Rack mount chassis orientation options – Front and rear mount. .........10 Figure 3: RSG2000 Series 19” Rack Mount Adapters .
Table 12: Twisted-Pair Port Specifications ......................................................................................29 Table 13: Fast Ethernet optical specifications ........................................................................
3 Product Overview 3.1 Functional Overview The RuggedSwitch ® RSG2100P is an industrially hardened, Power Over Ethernet (PoE) enabled, fully managed, modular, Ethernet switch specifica lly designed to operate reliably in electrically harsh and climatically demanding utility substati on and industrial envir onments.
• VLAN (802.1q) to segregate and secure network traffic • Radius centralized password management • SNMPv3 encrypted authentication and access security RuggedRated™ for Reliability in Harsh Env.
3.3 Display Panel Description The RSG2000 series products are equipped wi th a versatile display panel, shown in Figure 1 , which is designed to provide quick status informati on for each port, as well as the entire device to allow for simple diagnostics and troubleshooting.
The port-based LEDs can be cycled between three display modes: Status, Duplex, and Speed. Pushing the mode button causes the display mode to be cycled.
4 Inst allation 4.1 Mounting The RSG2000 series of products have been des igned with maximum mounting and display flexibility. Customers can or der an RSG2000 series switch that can be mounted in a standard 19” rack, 1” DIN Rail, or directly onto a panel.
4.1.1 Rack Mounting Figure 3: RSG2000 Series 19” Rack Mount Adapters Figure 4: Rack mount adapter mounting location The RSG2000 series family of products c an be rack mounted using the included rack mount adapter assemblies shown in Figure 3 .
4.1.2 Panel and DIN Rail Mounting The RSG2000 series products can be ordered as a Panel/DIN mount chassis. Both options involve the use of the panel/DIN adapters to be m ounted on each side of the chassis enclosure.
4.2 Power Supply Wiring and Grounding Figure 6: RSG2000 Series Philips Screw Terminal Block Philips Screw Terminal without Cover Philips Screw Terminal with Cover Safety Cover Safety Cover Screws Chas.
The RSG2100P can be equipped with either a Ph ilips Screw Terminal Block or a Phoenix Plug Terminal Block. The Philips Screw Terminal Bl ock has Philips screws with a compression plate allowing either bare wire connections or crimped te rminal lugs.
4.2.1 AC Po wer Supply (PS1) Wiring Ex ample Figure 9: AC (PS1) & 48VDC (PS2) power supply wiring examples NOTES: 1. 100-240VAC rated equipment: A 250VAC appropria tely rated circuit breaker must be installed. 2. Equipment must be installed according to the applicable country wiring codes.
4.2.2 DC Po wer Supply (PS1) Wiring Ex ample Figure 10: DC (PS1) & 48VDC (PS2 ) power supply wiring examples NOTES: 1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be installed. 2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
4.3 Dielectric Strength (HIPOT) Testing For dielectric strength (HIPOT) testing in the fiel d, users must remove the metal jumper located on terminal 2, 4, and 6 of the power supply terminal block.
4.4 Failsafe Alarm Relay Wiring The “Failsafe” output relay is provided to signal critical error conditions that may occur on the RSG2000 series switches. The contacts are energized upon power up of the unit and remain energized until a critical error occurs.
4.5 Console Port Wiring A RS232 console port for configuration and m anagement of the device is located on the LED display module shown in Figure 13. This port is intended to be a temporary connection during initial configuration or troubleshoot ing and allows for direct acce ss to the serial-based management console.
5 Ethernet Port s Each Ethernet module is equipped with two LEDs that i ndicate link/activity status information. The LED will be solid for ports with link, and wi ll blink for activity. The diagram in Figure 15 highlights the port and the associated link/activity LED.
10/100BaseTx Pin-out Pin Description 1 RX + 2 RX - 3 TX + 6 TX - 4, 5, 7, 9 NC Table 5: RJ45 Ethernet pin-out assignment 5.1.2 Data and Power Ports The RSG2100P comes standard with 4 10/100Bas eTX IEEE 802.3af (PoE) compliant Ethernet ports (ports 17 – 20).
5.2 Fiber Optic Ports Depending on the order code of the product, the RSG2000 series products can be equipped with several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be properly connected and matc hed for proper link and operation.
Figure 21: 100FX / 1000LX ST connector Figure 22: 1000LX GBIC Module and SC connector Figure 23: 1000LX SFP (mini-GBIC) Module and LC connector 23 © 2008 RuggedCom Inc.
5.2.1 Gigabit Ethernet 1000Base-Tx Cabling Recommendations The IEEE 802.3ab Gigabit Ethernet standard defines 1000Mbit/s Ethernet communications over distances of up to 100 meters using 4 pairs of category 5 (or higher) balanc ed unshielded twisted- pair cabling.
5.2.2 Pluggable optics – Installati on, rem oval, and precautions The RSG2000 series of products can be ordered wi th pluggable optic form factors such as SFP (Small Form-factor Pluggable) or GB IC (Gigabit Interface Converte r) modules.
5.2.2.2 GBIC Module Removal GBIC Modules have two locking latches on either side of t he module shown in Figure 25 . To remove GBIC module, disconnect any cable and repl ace with dust cover to protect the optics. User should depress both latches simultaneously and gently pull the module from the chassis.
6 T echnical S pecifications 6.1 Power Supply Specifications Input Range Max. Power Consumption 3 Power Supply Type (PS1) Min Max Fuse Rating 10/100TX FE Ports Worst Case 12 – 24 VDC 10 VDC 36 VDC 6.
6.3 Networking Standards Supported Parameter 10Mbps Ports 100Mbps Ports 1000Mbps Ports Notes IEEE 802.3 9 10BaseT / 10BaseFL IEEE 802.3u 9 100BaseTX / 100BaseFX IEEE 802.3z 9 1000BaseSX/LX IEEE 802.3ab 9 1000BaseTx IEEE 802.3x 9 9 9 Full Duplex Operation IEEE 802.
6.4 Twisted-Pair Port Specifications Parameter Specification Notes Speed 10/100 Mbps Auto-negotiating Duplex FDX / HDX Auto-negotiating Cable-Type > Category 5 Shielded/Unshielded Wiring Standard TIA/EI A T568A/B Auto-Crossover, Auto-polarity Max Distance 100 m Connector RJ45 Isolation 1.
6.5 Fiber Optical Specifications The following sections detail fiber optical specif ications on ports that can be ordered with the RSG2000 series Ethernet switch.
6.5.1 Fast Ethernet (10/100 Mbps ) Optical Specifications The dual-port fast Ethernet optic al specifications for RSG2100P ports 1-8 and 13-20 are shown below organized by module order code. Module order codes are contained within each product’s factory data when assembled and configured at the factory.
6.5.2 Gigabit Ether net (1000 M bps) Optical Specifications For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The table below details fiber optic specifications based on the 2-port modules or pluggable transceiver s selected at time of ordering.
NOTES: 1. Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please c onsult RuggedCom sales associates when determining maximum segment distances. 2. All cabling is duplex type unless otherwise specified.
6.6 Type Test Specifications Electrical Safety Levels Comments Dielectric Withstand 2 kV rms for 1 minute ANSI/IEEE C37.90 (1989) IEC 60255-5 (Section 6) High Voltage Impulse 5 kV peak IEC 60255-5 (Se.
6.8 Mechanical Specifications Parameter Value Comments Dimensions 18.29 x 10.17 x 1.74 inches (464,57) x (258,32) x (44,20) mm (Length x Width x Height) with mounting brackets installed Weight 10 lb (4.5 Kg) Enclosure 18awg galvanized steel Table 17: Mechanical Specifications Figure 28: Mechanical Specifications 35 © 2008 RuggedCom Inc.
36 © 2008 RuggedCom Inc. All rights reserved Rev105 7 Agency Approvals Agency Standards Comments CSA CSA C22.2 No. 60950, UL 60950 Approved CE EN 60950, EN 61000-6-2 Approved FCC FCC Part 15, Class A.
デバイスRuggedCom RSG2100Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RuggedCom RSG2100Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRuggedCom RSG2100Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RuggedCom RSG2100Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RuggedCom RSG2100Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RuggedCom RSG2100Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRuggedCom RSG2100Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RuggedCom RSG2100Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRuggedCom RSG2100Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。