PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US PUMP PFD1/PFS1 OPERATING INSTRUCTIONS SAINT - GOBAIN PERFORMANCE PLASTICS ASTI SAINT - GOBAIN PERFORMANCE PLASTICS ASTI (Headquarters) (Factory) 41, boulevard des Bouvets E.A.D.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US INDEX Page I – General 2 I.1 – Introduction I.2 – Materials I.3 – Operation description I.4 – Pump Data II – Quick checklist 2 II.1 – Shipment II.2 – Reception III – Installation and operation 3 III.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 2 /11 Thank you for selecting a SAINT - GOBAIN PERFORMANCE PLASTICS ASTI model PFD1 AstiPure™ pump, series 2 (or PFS1: slurry applications). I – General I.1 – Introduction The Model PFD/PFS is a pneumatically operated TEFLON ® pump.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 3 /11 II.2 – Reception U pon receipt of the pump, please check that: • The carton has not been damaged in transit. If there is any visible damage, immediately contact the carrier.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 4 /11 III.3.2 – Fluid connections The pump is self - priming. The inlet is at the bottom and the outlet at the top. Two optional fittings are available: • PFD1 210 or PFS1 210 : pump is supplied with flared fittings suitable for 3/8”x1/2” (10x13 mm) TEFLON ® tube.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 5 /11 IV.4 – Applications The PFD/PFS pump is a volumetric pump. The stroke volume is dependent on the flow rate and discharge pressure. In order to know the precise flow rate of the pump, a paddle wheel flow transmitter can be fitted on outlet.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 6 /11 If the pump starts, check that the following was not the cause: • The air/nitrogen connections (See III.3.1), • The air/nitrogen quality, • Has the pump been serviced correctly? (See V.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 7 /11 VI.1 – How to dismantle Before dismantling the pump, refer to the Maintenance schedule V.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 8 /11 VI.3.3 – Replacing the central shaft and shaft composite rings Follow the same steps described in V1.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 9 /11 • Squeeze the sleeve into a “ bean ” shape, then insert it in the sleeve insertion tool P/N 2680 (Figure 4): • While holding the O.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 10 /11 • Use the pick (P/N 1643) to correctly position the sleeve in its groove. Be careful not to damage the sleeve (Figure 7): • Repeat this operation for the 4 sets of rings.
PFD1/PFS1 – OPERATING INSTRUCTIONS INDEX DATE N° 03 27/09/01 DC01020US 11 /11 VI.3.7 – Replacing other parts When dismantling the pump or control unit for service, components found damaged should be replaced. Alternatively, the pump/control unit can be returned to your distributor or SGPPL ASTI for examination, estim ate, and repair.
PFD1/PF S1 – SPARE PARTS LIST INDEX DATE N° 03 27/09/01 DC01020US SAINT - GOBAIN PERFORMANCE PLASTICS ASTI 41 boulevard des Bouvets F - 92000 NANTERRE Tel: +33 (0) 1.55.68.59.59 Fax: +33 (0) 1.55.68.59.68 http:// www. astipure.com http://www.plastics.
PFD1/PFS1 – MAINTENANCE KITS INDEX DATE N° 03 27/09/01 DC01020US SAINT - GOBAIN PERFORMANCE PLASTICS ASTI 41 boulevard des Bouvets F - 92000 NANTERRE Tel : +33 (0)1.55.68.59.59 Fax : +33 (0)1.55.68.59.68 http:// www.astipure .com http://www.plastics.
REFER ENCE IN DICE Dessinépar: Endated u: DESIGN ATION j.Be ASTIPURE Pump1 APP1REF 03 SAINT-GOBAINPERFORMANCEPLASTICSAS TI 41BoulevarddesBouvets 92000Nanterre-France Tel:+33(0)155685959 Fax:+33(0 )155685968 http://www.
PART NUMBERS TABLE Piloting Fluid Size Connec- tion Sealing Option AB CD E F G H I J K L M PF (standard) 1 2701 2709 2728 2615 2613 2745 2739 2711 7145 2706 MS11013 PR 1 2826 2827 2828 2829 PO 1 2826 .
REFERENCE IN DICE S S S SG G G GP P P PP P P PL L L L A A A AS S S ST T T TI I I I 41 Boulevard des Bouvets F-92741 N anterre Cedex FRANCE Tel: +33 (0)1 55 68 59 59 Fax: +33 (0 )1 55 68 59 68 Dessiné par: Validé par: DATE: DESIGNATION FM 02/05/00 Pum p ASTIPURE 1 APP 1 EX T 00 134.
AstiPure™ PFD1 / PFS1 pump flow rate characteristics 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 50 150 250 350 450 550 650 750 Flow rate (l/h) Discharge head (bar) Air supply 5 bar Air supply 4 bar Air supply 3 .
REFERENCE INDICE Dessiné par: Validé par: DATE: DESIGNATION FM 09/05/00 ASTIPUR E Pum p 1 APP 1 CAB 00 S S S SG G G GP P P PP P P PL L L L A A A AS S S ST T T TI I I I 41 Boule v ard des Bouv ets F-92741 Nanterre Ced ex FRANCE Tel: +33 (0)1 55 68 59 59 Fax: +33 (0)1 55 68 59 6 8 VANNE DE R EGLAGE VALV E VANNE D' ARRET STOP Ø2.
デバイスSAINT-GOBAIN PFD1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SAINT-GOBAIN PFD1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSAINT-GOBAIN PFD1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SAINT-GOBAIN PFD1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SAINT-GOBAIN PFD1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SAINT-GOBAIN PFD1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSAINT-GOBAIN PFD1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SAINT-GOBAIN PFD1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSAINT-GOBAIN PFD1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。