OWNER’S INSTRUCTIONS & INST ALLA TION MANUAL FLOOR ST ANDING TYPE AIR CONDITIONER ( Cool ) AP500PF E S DB68-00054A(3).
Safety Precautions The following safety precautions must be taken when using your air conditioner . 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquids of any kind into the indoor unit.
Contents ◆ P REP ARING Y OUR A IR C ONDITIONER ■ Saf ety Precautions ......................................................................................................... 2 ■ View of the Indoor Unit & Outdoor Unit .......................
View of the Indoor unit and Outdoor unit AIR FLOW(DIRECTION) ADJUSTING BLADE AIR OUTLET CONTROL P ANEL AIR FIL TER AIR INLET GRILLE T o disassemble the air inlet grille ◆ Loosen two fixing screws of left and right. Hold the upper par t of the air inlet grille, and then pull it lightly forw ard.
Remote Contr ol - Buttons Contr ol P anel F an Speed display F an Speed adjustment Time/T emperature Selection Operating Mode Selection Timer adjustment P ow er Light Time or T emperature adjustment T.
Getting Star ted Y ou have just purchased a packaged air conditioner and it has been installed by your installation specialist. Y our Owner's Instructions contain much valuable information on using your air conditioner . Please take the time to read them as they will help you take full advantage of the unit's features.
Inser ting the Remote Contr ol Batteries Y ou must insert or replace the remote control batteries when: ◆ Y ou purchase the air conditioner ◆ The remote control does not work correctly N N N N o o o o t t t t e e e e Use two LR03(AAA) 1.5V batteries.
Setting the Time Y ou can set the time when you purchas the air conditioner . N N N N o o o o t t t t a a a a Be sure to reset the time when you change clocks from standard todaylight saving time and vice versa. 1 Press the TIME/TEMP . SELECT button. Result: The TIME indicator flashes.
Y ou can operate with indoor unit when you do not wish to or cannot operate the air conditioner with the remote control. Y ou can : Adapt the auto operating, cooling, f an and timer setting to your specific requirements ; See pages 10 to 15 f or fur ther details.
Y ou can start the air conditioner in AUTO mode. 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode pre viously set is displa yed. ◆ The air conditioner star ts up in the mode selected when the unit was last used.
Y ou must select the COOL mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode pre viously set is displa yed.
The turbo function is used to cool your room as quickly as possible. Example: Y ou have just come home and find that the room is very hot. Y ou wish to cool it down as quickly as possible. The turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
Airing Y our Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode pre viously set is displa yed.
Adjusting the Air Flow Direction Horizontall y Depending on the position of the indoor unit, you can adjust the position of the air flow blades on the top of the unit, thus increasing the efficiency of the air conditioner . Y ou can controll by using remote control.
Setting the Off Timer The Off T imer enables you to set the air conditioner to switch off automatically after a given period of time, by pressing one single button. The unit can be switched off automatically after one hour , two hours, three hours, four hours or five hours.
Operating Recommendation Here is a recommendation that you should follow when using your air conditioner . T OPIC RECOMMEND A TION P ower failure If a power f ailure occurs when the air conditioner is operating, the unit is s witched off . When the power returns, the air conditioner start up again automatically .
Cleaning Y our Air Conditioner T o get the best possible use out of your air conditioner , you must clean it regularly to remove the dust that accumulates on the air filter . IM PORT ANT Before c leaning your air conditioner , ensure that y ou have switched off the breaker used f or the unit.
Problem Explanation / Solution The air conditioner does not operate at all The air conditioner does not operate with the remote control The air conditioner does not cool The f an speed does not change.
T echnical Specification Cooling Capacity BTU/h Moisture Remov al Pts/h Indoor Air Flow (High) CFM Sound rating dBA P ower Source ø/V/Hz P ower Consumption W Operating Current A Max. TD Fuse/Break er A Dimension W x H x D in Shipping W eight Ibs Liquid Line O .
A CCESSOR Y P ARTS LIST • Connection P ar ts . . . . . . . . . . . . . . 21 • Others . . . . . . . . . . . . . . . . . . . . . . 21 SELECTION OF INST ALLA TION PLA CE • Indoor Unit . . . . . . . . . . . . . . . . . . . 22 • Outdoor Unit . . . .
ACCESSOR Y P ARTS LIST Connection Parts Others 1 2 3 4 5 6 7 8 9 Drain hose Connecting pipe Connecting pipe Connection wiring (3 strand) Insulation f or piping Finishing tape Insulation tape Insulation tube f or indoor unit piping connection Ring terminal 1 1 1 1 1 2 1 1 8 No .
SELECTION OF INST ALLA TION PLACE ❈ If there is any una voidab le reason to install the unit at such a place, tak e the follo wing measures against the wind; 1. When installing the unit at a roadside concentrated with buildings , install it parallel with the road.
ELECTRICAL WORK Po w e r Ampere of breaker Knif e switch Size of grounding wire Min. size of electric wires from/to the indoor/outdoor unit Size of electric input wires Switch Fuse 3phase 3wires 208 ~ 230V / 60Hz 50 A 30 A 30 A A WG 14 A WG 19 A WG 1 9 The electrical work should be performed by a specialist qualified f or the work.
ELECTRICAL WORK RS T RS T OUTDOOR SIDE P ower terminals on the outdoor unit Red Red White White Black Black Knif e switch or automatic circuit breaker Electric input wires Indoor / outdoor unit connecting wire 1. Remov e cover of electric box on side panel of outdoor unit.
ELECTRICAL WORK / INST ALLA TION METHOD INST ALLA TION METHOD INST ALLA TION METHOD Installation Procedures 1. Open the inlet grille, and remo ve the flare n ut. 2. Bend the connection pipe to an appropriate length using the spring bender depending upon the installation place.
A 1.8 mm(7/100") 2 mm(9/100") INST ALLA TION METHOD 90 Oblique Roughness Burr D A Outer Diameter ø 9.52 mm(3/8") ø 19.05 mm(3/4") ◆ Unproper flaring Inclined Surface damaged Crack ed Une ven thickness Final T orque 450 kg • cm(32 ft•lb) 750 kg • cm(54 ft•lb) Remarks Outer Diameter ø 9.
ACCESSORY P ARTS LIST INST ALLA TION METHOD Drilling a Hole in the W all Drain Hose Rat-prevention Cover ◆ Drill a hole of 70mm(3 inch) in diameter to the outside. ◆ The drilling should be done at a distance of less than 150mm(6 inch) from the floor f acing the indoor unit.
In order to install drain hose through wall, adjust height (max. 150mm/5.91 inch) of the indoor unit using leg holder . B A Anchor bolt fixing dimensions Nut A 840(33 inch) B 415(16.4 inch) Unit:mm(inch) Outdoor unit leg Leg holder Foot holder ❏ Fixing to the floor ◆ When using the leg holder of the indoor unit.
1. Connect the charging hose of low pressure side of manif old gauge to the pack ed valv e having a service por t (3/4" P ack ed valv e) as shown at the figure. 2. Open the valve of the lo w pressure side of manif old gauge counter-clockwise . 3.
REFRIGERANT CHARGING Air purge(at the time of new installation only) Close the gas pipe side valv e by tur ning it clockwise . Connect the pressure gauge to the low pressure side ser vice v alve , and then open the gas pipe side valv e again. Connect it to the refrigerant filling tank.
CHECK AND TEST OPERA TION ACCESSORY P ARTS LIST REFRIGERANT CHARGING / CHECK AND TEST OPERA TION CHECK AND TEST OPERA TION ◆ Be sure to check the f ollowing again after completion of installation. 1. Check the piping connection area f or any gas leakage.
CHECK AND TEST OPERA TION ◆ After chec king, read the owner’ s instructions carefully , and perf or m a test operation. Then deliver the unit to the customer . (When delivering the unit, be sure to read carefully and f ollow the contents of the o wner’ s instructions.
CHECK AND TEST OPERA TION MEMO MEMO E- 33.
ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY : Printed in Korea.
デバイスSamsung AP500PFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Samsung AP500PFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSamsung AP500PFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Samsung AP500PFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Samsung AP500PFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Samsung AP500PFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSamsung AP500PFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Samsung AP500PFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSamsung AP500PFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。