SamsungメーカーDVM-PRO 2008の使用説明書/サービス説明書
ページ先へ移動 of 27
SAMSUNG DVM-Pro 2008 User G uide 1 SAMSUNG DVM-Pro 2008 User ’s Manual ( Sales mode ) English V ersion 2008 . 02 . 28.
SAMSUNG DVM-Pro 2008 User G uide 2 Contents 1. User ’s manual for Sa les mode of DVM Pro 1-1. Architecture of sales mode 2. Top Down menu 2-1. File 2 - 2 . V i e w 2-3. Setup 2 - 4 . H e l p 3. Project 3-1. Project Information 3-1-1. Project name 3-1-2.
SAMSUNG DVM-Pro 2008 User G uide 3 6-1. Workspace 6-2. Piping 6-2-1. Select Indoor 6-2-2. Select Piping connection tools 6-2-3. Basic Pipe, Standard Pipe, Manual Pipe 6-2-4. Draw Piping manually 6-2-5. View Diagram 6-2-6. Check System 7. Wiring 8. Control System 9.
SAMSUNG DVM-Pro 2008 User G uide 4 1. User ’s manual for Sales mode of DVM Pro 1-1. Architecture of sales mode -. The sales mode of DVM Pro is an application software to help business of System A/C. It’s configured with Project, Indoor , Outdoor , Piping, Wiring, Control System and Report.
SAMSUNG DVM-Pro 2008 User G uide 5 -. Conversion.
SAMSUNG DVM-Pro 2008 User G uide 6 -. Languages 2-4. Help : Show the version information of DVM progra m and user can move to the related web page directly.
SAMSUNG DVM-Pro 2008 User G uide 7 3. Project : Set Project registration and Workspace. 3-1. Project Information : . User can register the project when start new project. User must fill out all blanks of project registration fields if new project. . Show the related information if it’s curr ent project.
SAMSUNG DVM-Pro 2008 User G uide 8 -. Setup buildin g a. Add Building : add t he building. -. New building is added if enter building code and name after press [add building]. * Can’t duplicate the code name and the code are configured with alphabet and Arabic.
SAMSUNG DVM-Pro 2008 User G uide 9 c. Add / delete floor : Can create or delete additional floor after make the floor. . -. New floor is added if enter building code and name after press [add floor]. * Can’t duplicate the code name and the code are configured with alph abet and Arabic.
SAMSUNG DVM-Pro 2008 User G uide 10 4. Indoor unit : User can select, add and delete I ndoor unit. And can select option per each Indoor unit. 4 - 1 Workspace : It shows the detailed information about workspace that displays, and can change, and using workspace that is using present in workspace selection window.
SAMSUNG DVM-Pro 2008 User G uide 11 after press [edit] button. 4-5. [View Indoor unit] window : It shows Indoor to be used. -. Display Indoor unit name, Model Na me, cooling temperature, cooling capacity, Cooling (kW), heating temperature, heating capacity, heating (kW), Indoor unit type, floor, K2 and etc.
SAMSUNG DVM-Pro 2008 User G uide 12 5. Outdoor unit 5-1. Workspace : It shows the detailed information about workspace that displays, and can change, and using workspace that is using present in workspace sele ction window. -. Choose workspace that wish to work.
SAMSUNG DVM-Pro 2008 User G uide 13 -. When add Outdoor unit, Outdoor unit of smallest capa city is added by workspace base. The capacity fluctuates automatically according to modification of the connected Indoor unit.
SAMSUNG DVM-Pro 2008 User G uide 14 - . I f t h e r e i s “ ” ICON In front of Outdoor unit ”, user must add more Indoor than combination rate. -. How to do if ondoor unit were connected with more Indoors than the combination rate ? . Add Outdoor unit.
SAMSUNG DVM-Pro 2008 User G uide 15 5-4. Delete Outdoor unit -. When delete Outdoor unit, it shows message that "do you want to delete the select ed “Outdoor xx?" if press “delete” button after select Outdoor unit to delete. It would be deleted if presses “yes”.
SAMSUNG DVM-Pro 2008 User G uide 16 5-6. Compensate Outdoor -. Outdoor Compensation can operate after refrigerant piping is linked, and it's not activated in case of there is more than combination rate. -. Select Outdoor unit to need [Compensate Outdoor].
SAMSUNG DVM-Pro 2008 User G uide 17 5-7. Window of Outdoor Information -. The detailed information regarding Outdoor unit and Indoor unit on the right-end screen is seen automatically.
SAMSUNG DVM-Pro 2008 User G uide 18 5-8. Indoor units not yet attached -. In case of there is unconnected Indoor u nit, piping connection mode is not activated. -. Delete it by delete command after select no needful indoor am ong unconnected Indoor unit 6.
SAMSUNG DVM-Pro 2008 User G uide 19 6-2-4. Draw Manual Pipe : User can edit the Piping at free. -. If check manual Pipe], piping connection tool is activated. -. Remove Net : It shows [Remove Net] if press a right mouse on the Ref Joint that is blue trian gle part of piping system diagram or on the Indoor unit.
SAMSUNG DVM-Pro 2008 User G uide 20 - . A f t e r [ R e m o v e N e t ] -. If remove net, square empty box appears and inserts the connection tool in the box and can connect user free piping.
SAMSUNG DVM-Pro 2008 User G uide 21 6-2-5. Viewing Diagram -. Full size : View the diagram on a large scale. -. Vertical : View the vertical diagram after check [vertical]. 6-2-6. Input Pipe length [Input Pipe length] shows if presses a right mouse on Ref Joint that is blue triangle part of piping system diagram or Indoor unit.
SAMSUNG DVM-Pro 2008 User G uide 22 -. If didn't set piping length at free, enter the piping length with clicking Apply piping length, "Do you apply the piping length of all visible units?" If window that will apply together comes out, press “yes”.
SAMSUNG DVM-Pro 2008 User G uide 23 -. If press close button, all inspections are expressed blue to piping system diagram, and it means that it's no issue to show blue color . -. If there is any issue while checking the sy stem, it shows error message.
SAMSUNG DVM-Pro 2008 User G uide 24 7. Wiring : Show electricity wiring state of indoor & outdoor units. 7-1. Workspace : It shows details information about workspace that displays and can change, and uses workspace that is using p resent in window of workspace selection.
SAMSUNG DVM-Pro 2008 User G uide 25 7-2. Select Outdoor unit : Can select wiring schematic diagram of Outdoor unit wanting in the same workspace. 8. Control system : Form control system. -. Press addition button, and input a name. -. Include Outdoor units to add in control us ing middle transfer button.
SAMSUNG DVM-Pro 2008 User G uide 26 -. If is ended, control diagram appears on screen. 9. Report.
SAMSUNG DVM-Pro 2008 User G uide 27 9-1. Insert Logo : S tore image file of logo to be used in report. 9-2. Report conte nts : equipment li st, Indoor unit spec ification, Out door unit spec ification, pi ping, wiring diagram and estimates. and displays or prints ONL Y the checked report.
デバイスSamsung DVM-PRO 2008の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Samsung DVM-PRO 2008をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSamsung DVM-PRO 2008の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Samsung DVM-PRO 2008の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Samsung DVM-PRO 2008で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Samsung DVM-PRO 2008を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSamsung DVM-PRO 2008の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Samsung DVM-PRO 2008に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSamsung DVM-PRO 2008デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。