SanyoメーカーECOiの使用説明書/サービス説明書
ページ先へ移動 of 32
ECOi TM V ariable R efrigerant Flo w (VRF), Multi-Zone, Heat P ump & Heat R eco v er y S y stems.
INTRODUCTION.. ..................................................2 ECOi™ Building Y our Business..................................3 ECOi™ . Y our Building Life T ool ..................................4 SANY O OUTDOOR Units ........................
INTRODUCTION E CO i™ . B u i l d i ng Y o u r B u s i n e s s . SANY O's Brand V ision SANYO HV AC consistently builds new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions.
Contractors. Buil ding Support. At SANYO, we realize contractors are looking for turnkey installation and support. ECOi™ is quite simply the perfect building solution. With its modular design and ease of installation, it’ s a solution that can grow with any building project.
INTRODUCTION For th e b ui ldi ngs re qui ri ng sim ult ane ou s h eat ing an d coo lin g, SANYO 3-Way ECOi™ system provides the perfect solution 05 05 C o m m e r ci a l o f f i c e b u i l d i n g.
MODELS (T ype: Nominal Cooling Capacity , etc) V olt PH CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R07263 72,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3.
SANY O OUTDOOR 07 DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.3 81,000 5.79 96,000 7.75 108,000 8.6 ELECTRICAL RA TINGS VOL T AG E R A TING COOLING RUNNING AMPERES HEA TING RUNNING AMPERES MIN.
WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263 WCHDZ 21663 / WCHDZ 24063 WCHDZ 26463 / WCHDZ 28863 K E Y F E AT U R E S : * T hre e -Way H ea t Re c ov er y * Co mbin e 3 ou td oor u nit s up t o 24 tons * .
SANY O OUTDOOR 09 WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery Combined Units DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (1) CHDZ07263 and (1) CHDZ07263 144,000 10.
WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery combined units DESCRIPTION WCHDZ 21663 WCHDZ 24063 WCHDZ 26463 WCHDZ 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDZ07263 216,000 15.
11 SANYO’ s Mini ECOi is suited for numerous commercial and premium residential applications. SANY O OUTDOOR CHX SERIES Mini ECOi Multi Split VRF Heat Pump CHX (R) 03652 / CHX (R) 05252 K E Y F E AT.
12 CHDX SERIES 2-W ay ECOi VRF Heat Pump DESCRIPTION (T ype: Nominal Cooling Capacity , etc) V olt PH CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 07263 * 72,000 BTU Heat Pump W ith Sal.
13 SANY O OUTDOOR CHDX SERIES 2- W ay ECOi VRF Heat Pump * NOTE : *460 V olt Step Down T ransformers (460-230) available for 6 and 8 ton condensers (R) indicates with salt protection - Special Order DESCRIPTION CHDX (R) 07263 CHDX (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.
14 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units WCHDX 14463 / WCHDX 16863 / WCHDX 19263 WCHDX 21663 / WCHDX 24063 WCHDX 26463 / WCHDX 28863 K E Y F E AT U RE S : * He at P um p * Co mbin e.
15 SANY O OUTDOOR WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (2) CHDX07263 144,000 10.
16 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 21663 WCHDX 24063 WCHDX 26463 WCHDX 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDX07263 216,000 15.
17 SANY O INDOOR KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862 KHX 1962 / KHX 2452 / A TK-SVRK56BA K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H .
18 THX SERIES Ceiling Suspended Unit DESCRIPTION THX 1252 THX 1852 THX 2452 CAP ACIT Y COOLING HEA TING 12,000 BTU 14,000 BTU 19,000 BTU 21,000 BTU 25,000 BTU 27,000 BTU CUR REN T COOLING HEA TING 0.14/0.17 A 0.14/0.15 A 0.15/0.14 A 0.15/0.17 A 0.34/0.
SYSTEM/MODEL Components (T ype: Nominal Cooling Capacity , etc) V olt PH 07 AHX 52 System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0752 cassette 208-230V/60 HZ 1 PNR-AH12.
XMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump 4-W ay Ceiling Cassette 24" x 24", with Condensate Pump 12 XMHX 52 / 18 XMHX 52 K E Y F E AT U RE S : * “EC O .
SANY O INDOOR XHX SERIES 4-W ay Ceiling Cassette 35" x 35", with Condensate Pump 24 XHX 52 / 36 XHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V .
UMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump UMHX 0762 / UMHX 0962 / UMHX 1262 UMHX 1562 / UMHX 1862 K E Y F E AT U RE S : * “E C O Fr ie nd ly ” R 410A R e f ri g.
SANY O INDOOR UHX SERIES Concealed Ducted - Medium Static DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462 PERFORMANCE COOL ING CAP A CITY HEA TING CAP ACIT.
DHX SERIES Concealed Ducted - Medium-High Static DESCRIPTION DHX 3652 DHX 4852 CAP ACIT Y COOLING HEA TING 36,000 BTU 39,000 BTU 47,800 BTU 54,600 BTU CUR REN T COOLING HEA TING 2.84/2.89 A 2.74/2.80 A 3.24/3.19 A 3.17/3.42 A POW ER INP UT COOLING HEA TING 548/620 W 528/602 W 644/695 W 627/756 W UNIT DIMENSIONS Inches (") / lbs.
SANY O INDOOR FHX/FMHX SERIES Floor Mounted FMHX 0762 / FMHX 0962 / FMHX 1262 FMHX 1562 / FMHX 1862 / FMHX 2462 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V ,.
CONTROL S Y S TEMS SANYO’ s system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put co nt rol in yo ur ha nds , l ite ral ly .
SANY O Control S ystem 27 CONTROL S Y S TEMS Simple System Control Network WIRED REMO TES SIMPLE TO INST ALL K E Y F E AT U RE S : ( S I M PL E RE M O T E ) * T hin and E as y T o Re ad * Simple T o I.
CONTROL S Y S TEMS Simple System Control Network SHA-K T 2 5 6BA Intel l igent Controll er K E Y F E AT U RE S ( INT EL L IGENT CONT ROL) : * 6.5 Inc h T ouch Scr een P anel * Co ntr ols up to 2 5 6 I.
SANY O Control S ystem 29 CONTROL S Y S TEMS Building Management Integration K E Y F E AT U RE S : * Co mmunica te W it h L onWork s Co mp atible Sy st ems * St ar t / St op * Co ntr ols Up T o 1 6 Groups ( Ma ximum 6 4 In door U nits ) * F o r 17 o r m or e g r o u p s o f in d o or u ni t s c on n e c t a d di t i o n a l inter fac e unit s.
30 A CCESSORIES P ART NUMBER DESCRIPTION 2-W a y Distr ibution Kits (cut to fit) Simple System Control Network APR -P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up t.
31 SERVICES SER VICES Simple System Control Network P ART NUMBER DESCRIPTION ECO -SC-4 ECOi COMMISSIONING (Per normal business day , up to 24 tons) IC -SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Ba.
Us age ○ T h e a i r c on d i t i o n e r s l i s t e d h e r e i n a r e o nl y f o r c o o l i n g / h e a t i n g a r e a s u s e d b y peo pl e. D o no t u se t h e un i t f or f oo ds , an ima ls , pla n t s, p r e ci si on m ac hi ne s, w o r k s o f a r t o r o t h e r o b j e c t s .
デバイスSanyo ECOiの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sanyo ECOiをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSanyo ECOiの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sanyo ECOiの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sanyo ECOiで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sanyo ECOiを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSanyo ECOiの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sanyo ECOiに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSanyo ECOiデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。