Schneider Electricメーカー890USE17700の使用説明書/サービス説明書
ページ先へ移動 of 194
31003688 01 Advantys STB Standard Ethernet Modbus TCP/IP Network Interfa ce Module Applications Guide 890USE177 00 Version 2. 0 31003688 01.
2 890USE17 700 April 2 004.
890USE17 700 April 2004 3 Tabl e of Cont en ts Saf ety In forma tion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Abou t th e Bo ok . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 1 Introduction .
4 890USE17 700 April 2 004 Chapt er 4 I P Pa rame ters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
890USE177 00 April 2 004 5 Chapter 6 Data Exchange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Data Exchan ge with the STB NIP 221 2 .
6 890USE17 700 April 2 004.
890USE177 00 April 2 004 7 § Safety Information Importa nt Inform ation NOTICE Read the se instru ction s careful ly, and l ook a t the eq uipment to becom e fami liar wi th the devic e befo re trying to insta ll, operat e, or ma intain it.
Safety Infor mation 8 890USE17 700 April 2 004 PLEASE NOTE Electrica l equipm ent sh ould be s ervice d only b y qualifi ed pers onnel. N o resp onsi- bility is assumed by Schneid er Elect ric for an y conseq uence s arising o ut of the u se of this ma terial.
890USE177 00 April 2 004 9 About the Book At a Glance Document Sc ope This Guide describe s the hard ware and software feature s of the Ad vanty s STB NIP 2212, which e nables an island of Advant ys STB modules to funct ion as a node on an Etherne t LAN.
About the Book 10 890USE17 700 April 2 004 Validity Note The data and i llustra tions foun d in this book are not bin ding. We res erve the ri ght to modif y our product s in line with our pol icy of cont inuous product dev elopmen t.
890USE177 00 April 2 004 11 1 Introduction At a Glance Introduction Thi s chapter provid es a gene ral overv iew of th e Adva ntys STB st andard network interface modul e and the Adva ntys STB island bus. The chap ter co ncludes with a n introdu ction to t he spe cific fea tures o f the ST B NIP 2212 NIM.
Introduction 12 890USE17 700 April 2 004 What Is a Network Int erface Module? Purpose Every i sland requires a network i nterfac e module (NIM) in th e leftm ost loca tion of the primary se gmen t. Physical ly, the NI M is the firs t (leftmo st) mod ule on the is land b us.
Introduction 890USE177 00 April 2 004 13 Integrated Pow er Supply The NIM’ s bui lt-in 24-to- 5 VDC po wer sup ply pro vides l ogic p ower to t he I/O modules on the primar y segmen t of the island bus. Th e power sup ply re quires a 24 VDC ext ernal power source .
Introduction 14 890USE17 700 April 2 004 Structural Overv iew The follow ing fig ure ill ustrates t he mul tiple role s of th e NIM. T he figu re prov ides a network view an d a ph ysical r eprese nta.
Introduction 890USE177 00 April 2 004 15 What Is Advant ys STB? Introduction Adv antys STB i s an ass embly of distribut ed I/O , power, a nd other m odules th at function t ogethe r as an island n ode on an open f ieldbu s netwo rk.
Introduction 16 890USE17 700 April 2 004 Extension Segments When yo u are usin g a st an dard N IM, Advan tys S TB I /O mo dul es th at do not resi de in the primary segme nt can be ins talled in extensio n segme nts . Extensio n segme nts are optiona l segm ents that enable an island to be a t ruly di stributed I /O sy stem.
Introduction 890USE177 00 April 2 004 17 Preferred Modules An island bus can also sup port tho se aut o-address able mod ules re ferred t o as preferred m odule s . Preferre d modul es do not moun t in segment s, but they do coun t as part of the 32-module maximu m syste m limit.
Introduction 18 890USE17 700 April 2 004 Standard CANopen Devices You may a lso i nstall one o r more st andar d CANop en devic es on an islan d. Thes e devices are n ot aut o-address able, and they must be in stalled at the end o f the islan d bus.
Introduction 890USE177 00 April 2 004 19 STB NIP 2212 Product Overview Introduction An Ad vanty s STB islan d bus co nfigured w ith an STB NIP 2212 standa rd NIM can function tra nsparentl y as a n ode on an Ethe rnet loc al area netw ork (LAN ), or on the Internet.
Introduction 20 890USE17 700 April 2 004 Conformance to NIM Standa rds The STB NIP 2212 is designed to sup port all of the st andard Advanty s STB NIM features and functions (See What Is a Network Inte rface Mo dule?, p.
Introduction 890USE177 00 April 2 004 21 Ethernet Communicat ions and Connect ivity Introduction The STB NIP 2212 allo ws the Ad vantys ST B island t o func tion as a node o n an Ethernet loc al area n etwork (LAN) .
Introduction 22 890USE17 700 April 2 004.
890USE177 00 April 2 004 23 2 The STB NIP 2212 NIM At a Glance Introduction Thi s chapter descr ibes t he externa l featu res of t he STB NIP 2212, i ncluding its Ethernet port , netw ork cabl e requirem ents, a nd powe r require ments.
The STB NIP 2212 NIM 24 890USE17 700 April 2 004 External Featur es of the STB NIP 2212 Summar y of Featu res The follow ing fig ure ind icates whe re the p hysica l featu res critic al to ST B NIP 2 .
The STB N IP 2212 NIM 890USE177 00 April 2 004 25 The phys ical f eatures of the STB NIP 221 2 are de scribed briefly in the fo llowing table: Feature Func tion 1 Ethernet interface An RJ-45 (See STB NIP 2212 Network Inter face, p. 26 ) connector is used to connect t he NIM and the island bus to an Ethernet LA N network.
The STB NIP 2212 NIM 26 890USE17 700 April 2 004 STB NIP 2212 Network Inter face Introduction The fieldb us interfa ce on the STB NIP 2212 is t he poi nt of co nnection between an Advantys STB island and the Eth ernet L AN on w hich the i sland resides .
The STB N IP 2212 NIM 890USE177 00 April 2 004 27 Communica tions Cable and Connector The require d commu nication s cable i s either s hielded (STP) or un shiel ded (UTP) electrica l, twis ted pair C AT5 ca ble. Th e cable u sed wit h the STB NIP 2212 must terminate with an e ight-pin m ale con nector.
The STB NIP 2212 NIM 28 890USE17 700 April 2 004 Rotary Switches Introduction The STB NIP 2212 is a si ngle n ode on an Etherne t LAN and, in turn, th e Intern et. An STB NIP 22 12 mu st have a uniqu e IP add ress. The two rotary s witches on the NIM prov ide a simple, easy way to a ssign a n IP add ress to the STB NI P 22 12.
The STB N IP 2212 NIM 890USE177 00 April 2 004 29 Summar y of Valid IP Addres s Settings Each rotary switch posit ion tha t you can u se to set a vali d IP address i s marked on the STB NIP 2 212 ho using (See Phy sical De script ion, p.
The STB NIP 2212 NIM 30 890USE17 700 April 2 004 LED Indicators Introduction Six LEDs on the STB NIP 2212 NIM visual ly indic ate the operation al sta tus of the island bus on an Ethernet LAN . The LED array is located towa rd the top of the NIM front beze l: LED 1 0T ACT (See Ethernet C ommun icatio ns LEDs , p.
The STB N IP 2212 NIM 890USE177 00 April 2 004 31 Ethernet Communica tions LED s The 10T AC T and t he STATUS i ndica te the con dition s descri bed in the followi ng table: Adva ntys STB Communica ti.
The STB NIP 2212 NIM 32 890USE17 700 April 2 004 off blink: 2 off Configuration mismatch detected after power up—at least one mandatory module does not match; the island bus is not started. off blink: 2 off Ass ignment error—the NIM has detected a module assignment error; the island bus is not started.
The STB N IP 2212 NIM 890USE177 00 April 2 004 33 The CFG Interface Purpose The CFG port is th e conne ction point to th e islan d bus for eith er a c omputer running the Advant ys co nfigurat ion softw are or an HMI panel.
The STB NIP 2212 NIM 34 890USE17 700 April 2 004 Connections An ST B XCA 40 02 prog ramming cable must be used t o conn ect the compute r running the Advanty s config uration software o r a Modbu s-capabl e HMI pan el to the NIM vi a the CFG port.
The STB N IP 2212 NIM 890USE177 00 April 2 004 35 The Power Supply Interface Introduction The NIM’s built-i n power sup ply requi res 24 VDC from an ex ternal SELV-rated power so urce. T he conne ction between the 24 VDC source and th e island is the male tw o-pin con nector illustrate d belo w.
The STB NIP 2212 NIM 36 890USE17 700 April 2 004 Connectors Use either: a screw type power c onnector, availabl e in a kit of 10 (model STB X TS 1120) a spring clamp power conne ctor, avai lable in a kit o f 10 (m odel STB XTS 2120) The follow ing ill ustrati ons show two view s of eac h powe r conne ctor ty pe.
The STB N IP 2212 NIM 890USE177 00 April 2 004 37 Logic Power Introduction Log ic power is a 5 VDC pow er signa l on the islan d bus tha t the I/O m odules requ ire for internal proce ssing. Th e NIM h as a buil t-in powe r supp ly that pro vides logic power.
The STB NIP 2212 NIM 38 890USE17 700 April 2 004 Logic Power Flow The figure below s hows h ow the NIM ’s integr ated po wer supp ly ge nerates lo gic power an d send s it acro ss the primary s egme.
The STB N IP 2212 NIM 890USE177 00 April 2 004 39 Selecting a Source Power Suppl y for the Isl and’s Logic Power Bus Logic Power Requirement s An external 24 VDC po wer supp ly is ne eded a s the sou rce for logic po wer to the island bu s. The extern al powe r supp ly co nnects to the is land’s N IM.
The STB NIP 2212 NIM 40 890USE17 700 April 2 004 Calculating the Wattage Requiremen t The amount of po wer (See Logic Po wer Flow , p. 38 ) that the ex ternal pow er supply must deliv er is a functio n of the numb er of modul es and the num ber of built -in power supplies install ed on the islan d.
The STB N IP 2212 NIM 890USE177 00 April 2 004 41 The exten ded is land bus conta ins three b uilt-in po wer sup plies: the suppl y buil t into the NIM , which resides in th e leftm ost locati on of t.
The STB NIP 2212 NIM 42 890USE17 700 April 2 004 Module Specificati ons Specifica tions Detail The genera l spe cificatio ns for the STB NIP 2212, wh ich is th e Ethernet n etwor k interface modul e (NIM) fo r an Advan tys STB island bu s, app ear in the follow ing table: General Specifica tions dimensions width 40.
The STB N IP 2212 NIM 890USE177 00 April 2 004 43 segments supported primary (required) one extension (optional) six maximum standards Ethernet conformance IEEE 802.
The STB NIP 2212 NIM 44 890USE17 700 April 2 004.
890USE177 00 April 2 004 45 3 Conf iguring th e Isl and Bus At a Glance Introduction The inform ation in t his chap ter des cribes th e auto-add ressin g and auto - configura tion pro cesses .
Configuring the Island Bus 46 890USE17 700 April 2 004 Auto-Addressi ng Introduction Eac h time tha t the i sland is powered up or re set, the NIM autom aticall y assign s a unique is land bus addre ss to each mod ule on the isla nd that will en gage i n data exchang e.
Configuring the Island Bus 890USE177 00 April 2 004 47 An Example For exam ple, i f you h ave a n isl and bu s wit h ei ght I/ O mod ules: 1 NIM 2 STB PDT 3100 24 VDC power distribution module 3 STB D.
Configuring the Island Bus 48 890USE17 700 April 2 004 Assoc iating the Module T ype with the Island Bus Lo cation As a resul t of the confi guratio n proc ess, t he NIM a utoma tically i dentif ies ph ysical location s on the is land b us with sp ecific I/O module ty pes.
Configuring the Island Bus 890USE177 00 April 2 004 49 Auto-Configu ration Introduction All Ad vanty s STB I/O modu les are shipped w ith a set o f predef ined pa rameters th at allow a n island to be o peratio nal as so on as it is initializ ed.
Configuring the Island Bus 50 890USE17 700 April 2 004 Install ing the STB XMP 4440 Optional Removable Memory Card Introduction The STB XMP 4440 rem ovable m emory card i s a 32-kbyte subs cribe r iden tificatio n module (SIM ) that le ts you sto re (See Sav ing Conf igurati on Data, p .
Configuring the Island Bus 890USE177 00 April 2 004 51 Installing the Card Use the followi ng proced ure to i nstall the card: Step Act ion 1 Punch out the removable memory card fr om the plastic card on which it is shipped. Make sure that the edges of the card are smooth after you punch it out.
Configuring the Island Bus 52 890USE17 700 April 2 004 Removing the Card Use the fo llow ing proce dure to rem ove th e card fro m the ca rd draw er. As a handlin g precautio n, avoid touchi ng the ci rcuitry on the rem ovable m emory c ard during its removal.
Configuring the Island Bus 890USE177 00 April 2 004 53 Using the STB XMP 4440 Opt ional Removable Memory Card to Configur e the Island Bus Introduction A remo vable memo ry card is rea d when an i sland is powere d on. If the c onfigu ration dat a on th e card is va lid, t he cur rent confi gura tion dat a in Fl ash m emory is overwritt en.
Configuring the Island Bus 54 890USE17 700 April 2 004 Initial Configuration and Recon figu- ration Scen arios Use t he fol lowi ng pro ced ure to set up an isla nd bus wi th co nfig urat ion dat a that was previous ly sa ved (See Savin g Confi guratio n Data, p .
Configuring the Island Bus 890USE177 00 April 2 004 55 The RST Button Summar y The RST fu nction is basi cally a Fla sh memo ry ove rwriting operati on. Thi s means that RST is fun ction al only after th e islan d has been su cces sfully co nfigure d at least once.
Configuring the Island Bus 56 890USE17 700 April 2 004 RST Functionality Introduction The RST functi on all ows you to re config ure the o peratin g paramete rs and val ues of an isl and by over wri ting th e curr ent co nfig urat ion i n Flas h memor y.
Configuring the Island Bus 890USE177 00 April 2 004 57 Overwriti ng Flash Memory with Factory Default Values The follow ing proc edure describes how to use the R ST fun ction to w rite defa ult configura tion da ta to Fl ash mem ory. Follo w this procedure i f you want to re store default se ttings to an is land.
Configuring the Island Bus 58 890USE17 700 April 2 004.
890USE177 00 April 2 004 59 4 IP Para meters At a Glance Introduction The inform ation in t his chap ter descri bes how IP paramet ers are assigne d to the STB NIP 2212 .
IP Parameters 60 890USE17 700 April 2 004 How the STB NIP 2212 Obtains IP Parameters Summary As a node on a TCP/I P network , the STB NIP 2212 r equires a va lid 32-bit IP address.
IP Para met ers 890USE177 00 April 2 004 61 Deriving an IP Address from a Media Acce ss Control (MAC) Addr ess The 3 2-bi t def ault I P add res s for th e STB NIP 2 212 is comp osed o f the l ast four octets of its 48-bit Media Acce ss Cont rol (MAC) a ddress .
IP Parameters 62 890USE17 700 April 2 004 MAC-Based IP Addr ess Example In the foll owing e xample, the hex p airs in the exam ple IEEE global ad dress (MAC addres s) 54.10 .2D .11 are c onver ted into a decim al numb er in th e derived IP addre ss. The d erived IP a ddress is 84 .
IP Para met ers 890USE177 00 April 2 004 63 The IP Address Assignment Process Determining the IP Address As show n in the fo llowing flow ch art, the STB NIP 221 2 perfo rms a s equence of checks to d.
IP Parameters 64 890USE17 700 April 2 004 IP Addr ess Software Priorities The I P add ressi ng met hod s for th e STB NIP 2 212 ar e pri orit ized i n the o rder liste d in the foll owing ta ble. Not e: The l ower rotary switc h must be set to eith er of the two INTERNAL positi ons (See Rotary Swit ches , p.
890USE177 00 April 2 004 65 5 STB NIP 221 2 Web Server At a Glance Introduction The STB NIP 2212 incl udes an emb edded w eb ser ver tha t is desc ribed in this chapte r. What's in this Chapter? This cha pter co ntains the follo wing se ction s: Section Topic Page 5.
STB NIP 2212 Web Serv er 66 890USE17 700 April 2 004 5.1 Introd uction to the Embedded Web Serve r At a Glanc e Introduction Thi s sectio n intro duces th e STB NI P 2212 emb edded web ser ver.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 67 About the Embedded Web Server Introduction The STB NIP 2212 incl udes a Hypert ext Transf er Protoc ol (HTTP) b ased embedded web se rver.
STB NIP 2212 Web Serv er 68 890USE17 700 April 2 004 Acces sing the STB NIP 22 12 Web Site Use the followi ng steps to acc ess the STB NIP 2212 web si te: Product Support Web P age Informatio n abou t how to contac t Schneid er Electric about your STB NIP 2212 product is availab le from the Support web page .
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 69 Properties Web Page Introduction The Properti es web p age disp lays STB NIP 221 2 stati stics, s uch as t he versio n of the kerne l and the exec utive , as we ll as th e commu nication s prot ocols fo r which the STB NIP 2212 is c onfigur ed.
STB NIP 2212 Web Serv er 70 890USE17 700 April 2 004 5.2 Web Se rver C onfi gur ati on Opt ions At a Glanc e Introduction The informa tion in this sect ion des cribes the config uration option s supporte d by the STB NIP 221 2 embe dded we b server.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 71 Configurati on Web Page Introduction The web-bas ed resourc es tha t are a vailable for con figuring t he STB NIP 2212 are listed as option s on the C onfigur ation men u. The s pecific we b page f or each feature is linke d to a m enu opti on.
STB NIP 2212 Web Serv er 72 890USE17 700 April 2 004 Configuri ng an IP Address for the STB NIP 2212 Introduction To c ommuni cate as a node on the Internet, the field bus (Etherne t) port o n the STB NIP 2212 must be co nfigure d with a vali d IP address.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 73 IP Parameters T he IP add ress for t he ST B NI P 22 12 has the four par amete rs, w hic h are desc ribe d in the followi ng table: Using the Comm.
STB NIP 2212 Web Serv er 74 890USE17 700 April 2 004 Assigning a Configured IP Address to the STB NIP 22 12 Use the f ollowin g procedure to configu re an IP address for th e STB NIP 2212. No te: Your STB NIP 2212 cannot hav e a role na me. Step Action Commen t 1 Set the lower rotary switch to an INTERNAL position (See Physical Descr iption, p.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 75 Restoring Default Parameters from the Web Use the followi ng proced ure to re config ure the STB NIP 221 2 with i ts defa ult IP paramete rs (See D eriving an IP Ad dress from a Media Access Control (MAC) Address, p .
STB NIP 2212 Web Serv er 76 890USE17 700 April 2 004 About the Reboot Option The reboot operati on will configure the STB NIP 2212 with IP para meters as signed on the w eb.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 77 Configuring Master Controllers Introduction Any control ler on the Eth ernet ne twork ha s the po tential to b ecome th e mast er of an island on that n etwork. M aster y can be obtain ed on a first-com e/first -serve bas is.
STB NIP 2212 Web Serv er 78 890USE17 700 April 2 004 Setting Up Maste r Controllers for the Islan d Use the fol lowing procedure to con figure a master con troller f or the ST B NIP 2212 : Sample M as.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 79 Master Configurat or Web Page What I s a Master Configurator? The maste r confi gurator of an Ad vantys ST B island c ontrol s the con figurat ion da ta for all of t he I/O modul es during its re servation time (See Fields on the Master Configur ator Web Page, p.
STB NIP 2212 Web Serv er 80 890USE17 700 April 2 004 Fiel ds o n the Maste r Configurator Web P age The fields on the M aster Co nfigurat or web pa ge are d escribed i n the fo llowing table: Configur.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 81 Sample M aster Configurator Web Page A sample Maste r Con figurato r web pa ge is sho wn in th e follo wing fi gure:.
STB NIP 2212 Web Serv er 82 890USE17 700 April 2 004 Configuri ng a Role Name Introduction You c an assig n, edit, or delete a role name for an STB NIP 2212 on t he Role Name web page . A role name c omprises the STBNIP22 12 part numb er, an und erscore (_), and three n umeric c harac ters, e.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 83 Configuring a Role Name Use the following p roced ure to cr eate or edit a rol e name for the STB NIP 221 2: Step Action Comm ent 1 Set t he lower rotary swit ch to an INTERNAL position (See Ph ysical Description, p.
STB NIP 2212 Web Serv er 84 890USE17 700 April 2 004 About the Reboot Option The reboot o peratio n will co nfigure the STB NIP 2212 with a role name assig ned on the web.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 85 5.3 Web Server Security At a Glance Introduction The informa tion in th is sectio n descr ibes how the HTTP defau lt passw ord, the web access passwor d, and the confi guratio n password are us ed to prote ct the STB NIP 2212 web si te.
STB NIP 2212 Web Serv er 86 890USE17 700 April 2 004 Web Access Password Protection Summary The STB NIP 2212 web s ite is pa ssword-prote cted. Initially , security for the STB NIP 221 2 web s ite is provided by a d efault us er name and pass word.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 87 What Is t he Web Acces s Password? The web acc ess passw ord is an e ight-chara cter, cas e-sensiti ve user n ame and passwo rd that you assi gn. You r valu es will replace t he defa ult pro tectio n for yo ur STB NIP 2212 web si te.
STB NIP 2212 Web Serv er 88 890USE17 700 April 2 004 Setting Up the Web Ac cess Login Use the following proced ure to set up you r web ac cess us er nam e and pas sword: Step Action Result 1 Navigate to your url: http://configured IP address . The STB NIP 2212 home page is displayed.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 89 Configurati on Password Protection Introduction The confi guratio n passw ord contro ls read/write a ccess from the STB N IP 2212 web site to the phys ical mo dule’s Flash m emory. Th is pa ssword mus t be set up on th e Change Co nfigura tion Pa ssword web page .
STB NIP 2212 Web Serv er 90 890USE17 700 April 2 004 Sample Lo gin Prompt When acti ve, th e login pro mpt i s displa yed in the web banner (as shown in the foll owin g fig ure) .
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 91 5.4 Web Server Diagnostic Options At a Glance Introduction The inform ation i n this s ection describ es the diagno stics options supp orted by the STB NIP 2212 embe dded we b server.
STB NIP 2212 Web Serv er 92 890USE17 700 April 2 004 Diagnostics Web Page Introduction The web-based resourc es that are avai lable for troubl eshoo ting the STB NIP 221 2 are liste d as op tions on the Diag nosti cs menu . The web page for e ach fe ature is linked to a men u opti on.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 93 Ethernet St atistics Introduction The Ethernet Statist ics web pa ge repo rts status informat ion an d errors that are related to data tra nsmiss ions t o and fr om the STB NIP 2212 over the Ethe rnet LAN.
STB NIP 2212 Web Serv er 94 890USE17 700 April 2 004 STB NIP 2212 Registers Web Page Summary The NIM R egister s web p age wil l dis play info rmatio n abou t spec ific Mod bus registers in the STB NIP 2212 process image . The regi sters to display are iden tified by their M odbus reg ister add resses.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 95 Sample NIM Registe rs Web Page A sample NIM Re giste rs web p age ap pears i n the f ollowin g figure : 1 10-character variable name 2 Modbus regi.
STB NIP 2212 Web Serv er 96 890USE17 700 April 2 004 I/O Da ta Va lues Web Pa ge Summary The I/O Dat a Value s web pa ge will display the v alues st ored in the pro cess imag e output data area (Se e Th e Output D ata Proce ss Image , p. 119 ) and i nput data a rea (See The In put Data and I/ O Stat us Pr oce ss Im age, p.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 97 Sample I/O Da ta Values We b Page A sample I/O Data Values web page app ears in the follo wing fig ure: 1 module’s island bus node address 2 Adv.
STB NIP 2212 Web Serv er 98 890USE17 700 April 2 004 Island Configu ration Web Page Introduction The Islan d Config uration w eb pag e descri bes the c onfigu ration and oper ational st atus ( See Fault Dete ction, p. 132 ) of every mo dule curre ntly a ssembl ed on t he island b us.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 99 Island Par ameters Web Page Sample Is land Parameters Web Page The Island Paramete rs web pa ge disp lays a rea d-only list of the is land’ s paramete rs and their c urrent val ues.
STB NIP 2212 Web Serv er 100 890USE17 700 April 2 004 Error Log Web Page Introduction Sys tem-wid e informa tion c ollected while th e Adva ntys STB is land is operati onal is reported on the Error Log web page.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 101 Error Log Oper ations The operati ons a ssociated w ith the Er ror Log w eb page are de scribed i n the followi ng table: To ... D o ... Comment Display the E rror Log web page. Click on th e Diagnostics tab t o display the D iagnostics menu (See Diagnostics Web Page, p.
STB NIP 2212 Web Serv er 102 890USE17 700 April 2 004 5.5 SNM P Ser vic es At a Glanc e Introduction The STB NIP 2212 con tains a Sim ple Ne twork Mana gemen t Protocol (S NMP) agent, which is descri bed in this sec tion.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 103 SNMP Device Manageme nt Introduction The STB NIP 2212 cont ains a Sim ple Ne twork Manag ement Protocol (SNM P) Ver sio n 1.0 agent that is capable of su pportin g up to thre e concurr ent SN MP conne ctions.
STB NIP 2212 Web Serv er 104 890USE17 700 April 2 004 SNMP Protocol Data Units (PDUs) Protocol Data U nits (PDUs) wi thin SNMP carry re quests and respons es betwe en the manager a nd the STB NIP 2 212 agen t.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 105 Configure SNMP Web Page Introduction The Configu re SNM P web pa ge allow s you to view th e param eters use d by t he SNMP agent cont ained in the STB NIP 2212.
STB NIP 2212 Web Serv er 106 890USE17 700 April 2 004 Sample Configure SNMP Web P age A sample Conf igure SNM P web pa ge is sho wn i n the foll owing fi gure:.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 107 About the Schneider Priva te MIBs Introduction The followi ng info rmation d escribes the Sc hneider Ele ctric private M IB, and the Transparen t Facto ry Ethern et (TFE) a nd othe r subtrees that a pply to th e STB NIP 2212 .
STB NIP 2212 Web Serv er 108 890USE17 700 April 2 004 Transp arent Factor y Ethernet (TFE) Subtree Under the Gr oupe_Schn eider MI B is a Tran sparen t_Fact ory_Etherne t (TFE) private MIB that is cont rolled by the TFE SNM P emb edded com ponen t.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 109 Transparent Facto ry Ethernet (TFE) MIB Subtree Introduction The Transp arent Facto ry Ethe rnet (TFE) p rivate is a su btree of the Groupe_Sc hneid er privat e MIB. The TFE SNMP c omponen t contr ols Groupe_Sc hneid er’s priva te MIB f unction.
STB NIP 2212 Web Serv er 110 890USE17 700 April 2 004 Port502 Messagi ng Subtre e Introduction Port5 02 se rvices s upport TFE s ervices . Port502 servi ces manage expl icit clie nt/ server commun icati ons that s upport applicati ons, e .g., HMI data c ommunic ations.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 111 Web MIB Subtree Introduction The Web MIB sub tree, OI D 5, define s objec ts for manag ing emb edded we b serve r activity .
STB NIP 2212 Web Serv er 112 890USE17 700 April 2 004 Equipment Profil es Subtree Introduction The Equipmen t_Profil es su btree (OID 7) identi fies o bjects fo r every device type i n the TFE prod uct po rtfolio.
STB NIP 221 2 Web Serv er 890USE177 00 April 2 004 113 profileSlot(10) value=127 profileCPUType(11) Advantys STB profileTrapTableEntries Max(12) managers not required; value is 0 profileTrapTable(13) .
STB NIP 2212 Web Serv er 114 890USE17 700 April 2 004.
890USE177 00 April 2 004 115 6 Data Exchange At a Glance Introduction Thi s chapter desc ribes how data stored in the pro cess im age i s excha nged b etween the STB NIP 2 212 an d the Et hernet netw ork, vi a Modb us over T CP/IP.
Data Exchange 116 890USE17 700 April 2 004 Data Exchange with the STB NIP 2212 Introduction D ata exch ange be tween a Modbu s over TC P/IP hos t or th e HTTP em bedded web server and the Ad vanty s STB island b us is c onduc ted over th e Ethern et port on t he STB NIP 2212.
Data Exchange 890USE177 00 April 2 004 117 Data and Sta tus Objects Data exc hange be tween th e isla nd and the field bus mas ter involv es th ree object types: data obj ects, which a re operat ing v.
Data Exchange 118 890USE17 700 April 2 004 A Data Exchang e Example The exam ple uses the s ample is land b us asse mbly , as illus trated in the fol lowing figure.
Data Exchange 890USE177 00 April 2 004 119 The Output Data Process Image The out put data pr ocess image c ontain s the data writ ten to t he isl and from t he Modbus o ver TC P/IP hos t. This da ta is used t o update th e outp ut mod ules on t he island bu s.
Data Exchange 120 890USE17 700 April 2 004 The Input Data and I/O Status Proces s Image Input data and I/O s tatus inform ation fr om the I/O modules are sent to the input process image area. The fieldbus master or another moni toring dev ice, e. g., an HMI panel (See Th e HMI Blocks i n the Islan d Data I mage, p.
Data Exchange 890USE177 00 April 2 004 121 In total, the Modbu s over TCP/IP sam ple islan d bus re quires 18 registe rs (regi sters 45392 thro ugh 454 09) to sup port ou r confi guratio n: register 4.
Data Exchange 122 890USE17 700 April 2 004 register 45400 STB D DI 3610 d ata 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 ON/OFF conditions of inputs 1 . .. 6 always 0 register 45398 STB DDO 3410 echo ou tp.
Data Exchange 890USE177 00 April 2 004 123 register 45405 ST B AVI 1270 channel 1 statu s 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 register 45406 STB AVI 1270 c hannel 2 data 15 14 13 12 11 10 9 8 7 6 5 .
Data Exchange 124 890USE17 700 April 2 004 register 45409 STB AVO 125 0 channel 2 status 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 register 45408 STB AVO 1250 channel 1 status 15 14 13 12 11 10 9 8 7 6 5 .
Data Exchange 890USE177 00 April 2 004 125 Reading Diagnostic Data Summar y Thirty-f ive conti guous re gister s (45357 through 45391) in the island b us data image (See The Da ta Im age, p . 16 6 ) are reserv ed for dia gnosti c data ab out the Advantys STB sy stem.
Data Exchange 126 890USE17 700 April 2 004 Isl and Communica tions Status Status info rmation about th e state of comm unicatio ns acr oss the island bus is sto red in regist er 4535 7. The b its in the low by te (bits 7 through 0) use fif teen di fferent pattern s to ind icate the isla nd’s curren t commu nication s’ st ate.
Data Exchange 890USE177 00 April 2 004 127 11 Serious configuration mismatch—the island bus has been set to pre-operational m ode, and initialization is aborted. 12 The configuration matches, and the isl and bus is operational. 13 The island is operational with a configuration mismatch.
Data Exchange 128 890USE17 700 April 2 004 Error Reporting Each bit in re gister 45358 ind icate s a spec ific g lobal error condi tion. A value of 1 indi cates an er ror: 1 Fatal error. Because of the severity of the error, no further communicatio ns are possible on the island bus.
Data Exchange 890USE177 00 April 2 004 129 Node Configuration The next e ight cont iguous registers (regis ters 4535 9 throug h 4536 6) displa y locations where mo dules have been c onfigu red on the isl and bus . This inform ation is stored in Fla sh me mory.
Data Exchange 130 890USE17 700 April 2 004 Node Assembly Th e next eight conti guo us reg iste rs (r egist ers 45 367 t hroug h 4537 4) in dica te th e presence or abs ence of c onfigu red mo dules in locat ions o n the i sland bu s. This informati on is stored in Flash memor y.
Data Exchange 890USE177 00 April 2 004 131 Emergency Messag es The next e ight cont iguous registers (regis ters 4537 5 throug h 4538 2) indica te the presence or abs ence of ne wly rec eived emergenc y mess ages for indi vidual modules on the island .
Data Exchange 132 890USE17 700 April 2 004 Fault Detection T he nex t ei ght co ntig uous r egist ers (regi sters 453 83 thro ugh 4539 0) in dicat e the presence or abs ence of o per ational fa ults d etecte d on the i sland bus modules .
Data Exchange 890USE177 00 April 2 004 133 STB NIP 22 12 Status Regis ter Regist er 45391 c ontains a word of diagn ostic data that is all ocated to the s tatus of the STB NI P 2212 . The bit s in th e high byte have p redef ined mean ings t hat a re common to all of the NIM s used with the Advant ys STB isl and.
Data Exchange 134 890USE17 700 April 2 004 Modbus Commands Supported by the STB NIP 2212 Introduction Mo dbus i s the prot ocol u sed b y Modic on PLCs. Modbus d efines the mes sage struct ure that the PLCs un derstan d and use, regard less of network t ype.
Data Exchange 890USE177 00 April 2 004 135 List of Suppo rted Commands The followi ng table lists the Mo dbus comm ands that the STB NIP 221 2 supports: Modbus Function Cod e Subfu ncti on or Subind ex Command Valid Range Max.
Data Exchange 136 890USE17 700 April 2 004 Ethernet Statist ics Ethernet st atisti cs comp rise s tatus info rmatio n and errors relate d to da ta transmis sions to and fro m the STB NIP 2212 over the Ethernet LAN.
Data Exchange 890USE177 00 April 2 004 137 Modbus Error Codes Introduction D uring operat ions, y ou may e ncoun ter Modbus error cod es that are returned by the STB NIP 2212 NIM to the Adv antys co nfigura tion softw are. These error codes are display ed as b yte code s in h exade cima l format .
Data Exchange 138 890USE17 700 April 2 004.
890USE177 00 April 2 004 139 7 Connection Example At a Glance Introduction The in forma tion in th is ch apte r pro vid es an ex ampl e sh owin g how t o conn ect and commis sion a n Advanty s STB is land with an ST B NIP 2212 gatew ay on a Modbus ove r TCP/IP (Ethernet ) network.
Connection Example 140 890USE17 700 April 2 004 Introduction Overv iew The conne ction exam ple that follow s descri bes ho w to co nnect a nd co mmissi on an Advantys STB island with an STB NIP 221 2 Ethern et gatewa y modul e. The connecti on ex ample does not use a speci fic Eth ernet h ost becau se M odbus over TCP/IP is an open protoc ol.
Connection Example 890USE177 00 April 2 004 141 Network Architecture Architec tural Diagram The p hysi cal ne twork shown in t he fol lowi ng fi gure i s repr esen tati ve of how Advantys STB island s.
Connection Example 142 890USE17 700 April 2 004 Sample Configur ation Example A rep resent ative isl and bu s ass embly wi th an ST B NIP 2212 gatew ay is s hown in the followi ng fig ure: 1 STB NIP 2.
Connection Example 890USE177 00 April 2 004 143 The I/O m odules in the s ample as semb ly have the fol lowing i sland bus add resses : The PDM and the term inatio n plate ar e not address able (See Ad dressa ble Mo dules, p.
Connection Example 144 890USE17 700 April 2 004 Input Proces s Ima ge The I/O m odules i n the s ample is land (See Exa mple, p. 142 ) requ ire 18 Modbu s registers in th e input d ata im age ar ea (See The Inpu t Data and I/O Statu s Process Image, p.
Connection Example 890USE177 00 April 2 004 145 Output Proc ess Image The I/O m odules in the s ample is land b us asse mbly require fiv e Mod bus regis ters in the output data imag e area (See T he Outpu t Data Process Image, p.
Connection Example 146 890USE17 700 April 2 004 Modbus Functions Supported by the STB NIP 2212 Introduction The STB NIP 2212 sup ports the M odbus fu nction ality tha t is de scribed below. Operati ons Summary A Modbus over TCP/IP fieldbus m aster can read an d write to the Modbus regis ters in the STB NIP 221 2.
Connection Example 890USE177 00 April 2 004 147 Request an d Respon se Example The follow ing exa mple uses the data fro m cha nnel 1 an d chan nel 2 in the STB AVO 1250 modul e (node 8 i n the s ample Ad vantys ST B island b us) (See Example, p. 142 ).
Connection Example 148 890USE17 700 April 2 004 List of Suppo rted Funct ion Codes and Their Descrip tions The follow ing tab le list s the fun ction co des th at can be used b y Modbus over TC P/ IP .
890USE177 00 April 2 004 149 8 Advanced Configuration Features At a Glance Introduction Thi s chapt er describe s the advanc ed and/o r optiona l configura tion fea tures tha t you can add to an Adv antys STB islan d.
Advanced Configuration Feat ures 150 890USE17 700 April 2 004 STB NIP 2212 Configurable Parameter s Introduction The followi ng inf ormation d escribes how to the confi gure pa rameter s for the STB NIP 221 2 usin g the Ad vantys config uration softwar e.
Advanced Configurat ion Features 890USE177 00 April 2 004 151 Selecting t he Displa y Format By default , the va lues for the config urable N IM para meters us e decim al not ation.
Advanced Configuration Feat ures 152 890USE17 700 April 2 004 Reserving Data Sizes To transf er data to th e PLC from a M odbus HMI pan el att ached to the CFG port, yo u must res erve spac e for th at data.
Advanced Configurat ion Features 890USE177 00 April 2 004 153 Configuring Mandatory Modules Summar y As pa rt of a cus tom c onfi gura tion, you can ass ign mandatory s tatus t o any I/O module or pref erred devi ce on a n island . The m andato ry design ation indic ates that you cons ider th e module or devic e criti cal to yo ur applic ation.
Advanced Configuration Feat ures 154 890USE17 700 April 2 004 Recovering from a Manda tory Stop Pushing th e RST but ton (See The RST Bu tton, p. 55 ) w hile reco vering from a mandatory stop will lo ad the island’s defau lt config uration data.
Advanced Configurat ion Features 890USE177 00 April 2 004 155 Prioritizi ng a Module Summar y Using t he Advanty s con figurat ion softw are, y ou can as sign priority to digit al inp ut mod ules i n yo ur is land ass embly . Pri ori tiza tio n is a meth od of f ine tuni ng th e NIM ’s I/O scan o f the i sland bu s.
Advanced Configuration Feat ures 156 890USE17 700 April 2 004 What Is a Reflex Acti on? Summary R eflex ac tions are smal l routin es th at perfor m dedic ated lo gical fu nction s dire ctly on the Advanty s island bus .
Advanced Configurat ion Features 890USE177 00 April 2 004 157 Configuring a Reflex Action Each bloc k in a refl ex ac tion mus t be confi gured using the Advant ys co nfigura tion software. Each bloc k mus t be a ssigned a se t of inpu ts an d a re sult.
Advanced Configuration Feat ures 158 890USE17 700 April 2 004 Result of a Reflex Block Dependi ng on t he type of reflex block tha t you u se, it wi ll output e ither a Boolea n or a word as its re sult.
Advanced Configurat ion Features 890USE177 00 April 2 004 159 Nesting The Adva ntys c onfig urat ion soft ware all ows y ou to crea te ne sted refl ex ac tion s. On e level of n esting i s support ed—i.e., two refle x blocks, where the result of the first block is an operat ional input t o the s econd bl ock.
Advanced Configuration Feat ures 160 890USE17 700 April 2 004 Number of Reflex Blocks on an Isl and An island can sup port up to 10 re flex bloc ks. A nes ted refl ex actio n consumes two blocks. An indivi dual o utput mod ule ca n support up to tw o reflex bloc ks.
Advanced Configurat ion Features 890USE177 00 April 2 004 161 Island Fal lback Scen arios Introduction In the ev ent of a com municat ions failure o n the island or bet ween th e isl and and the fieldbus, output data i s put into a safe fallback s tate.
Advanced Configuration Feat ures 162 890USE17 700 April 2 004 Fallback States for Reflex Funct ions Only an ou tput mo dule chan nel to w hich the res ult of a re flex actio n (See What I s a Reflex Act ion?, p. 156 ) has been m appe d can op erate i n the absen ce of th e NI M’s heartbeat m essage .
Advanced Configurat ion Features 890USE177 00 April 2 004 163 Saving Configurat ion Data Introduction The Advant ys confi guratio n soft ware all ows yo u to s ave confi guratio n data create d or modifie d with this software to the NIM ’s Flash memory a nd/or to the remov able memory card (See Physi cal D esc ript ion, p.
Advanced Configuration Feat ures 164 890USE17 700 April 2 004 Protecti ng Configurati on Data Introduction As p art of a cust om config uratio n, you can pass word-prot ect an Advant ys STB island.
Advanced Configurat ion Features 890USE177 00 April 2 004 165 A Modbus View of the Island’s Dat a Image Summar y A block of M odbus reg isters is reserve d in the NIM to ho ld and m aintain th e isla nd’s data image. Overal l, the data image holds 99 99 regi sters.
Advanced Configuration Feat ures 166 890USE17 700 April 2 004 The Da ta Image The 99 99 con tiguou s registe rs in t he Mod bus d ata image start a t regist er 400 01.
Advanced Configurat ion Features 890USE177 00 April 2 004 167 Reading Registe r Data All the regi sters in the data im age can be read by an H MI panel conne cted t o the island at the NIM ’s CFG po rt (See The CFG Interface , p.
Advanced Configuration Feat ures 168 890USE17 700 April 2 004 The Islan d’s Process Image Blo cks Summary Tw o blocks of regist ers in the island’s data image (See The Da ta Im age, p. 166 ) are the focus for thi s discuss ion. Th e first blo ck is th e outpu t data p rocess i mage, which starts at reg ister 40001 an d goes to reg ister 44096.
Advanced Configurat ion Features 890USE177 00 April 2 004 169 Output Data Read/Write Capabilitie s The regist ers in the out put dat a proce ss imag e are re ad/write- capabl e. You can read (i.e., mon itor) the proces s image using an HMI pa nel or the Ad vanty s configura tion so ftware.
Advanced Configuration Feat ures 170 890USE17 700 April 2 004 The HMI Blocks in the Isla nd Data Image Summary An H MI pane l that c ommuni cates us ing th e Modbus protoc ol can be conn ected to the CFG port (See Th e CFG Interfa ce, p. 33 ) on the NIM.
Advanced Configurat ion Features 890USE177 00 April 2 004 171 HMI Output Data Exchange In turn, output da ta writt en by the field bus master can be use d to update enun ciato r elements on the H MI panel .
Advanced Configuration Feat ures 172 890USE17 700 April 2 004.
890USE177 00 April 2 004 173 Glossary 10Ba se-T An adaptation of th e IEEE 80 2.3 (Ethe rnet) stand ard, the 10Base-T s tandar d uses twisted -pair wiring with a maximum segment le ngth of 100 m (328 ft) an d termina tes with an RJ -45 co nnector.
Glos sary 174 890USE17 700 April 2 004 ARP address res olution pro tocol. The IP ne twork layer prot ocol, whi ch uses ARP to map an IP addre ss to a M AC (ha rdware) ad dress. auto bau d The automatic a ssignm ent and detectio n of a c ommon b aud rat e as wel l as the ability o f a dev ice on a network to ada pt to that ra te.
Glossary 890USE177 00 April 2 004 175 CAN controlle r area ne twork. The CAN p rotoco l (ISO 11898) f or serial b us ne tworks is designed for the interconn ection of smart devic es (from m ultip le manufa cturers ) in smart sy stems fo r real-ti me indus trial appl icati ons.
Glos sary 176 890USE17 700 April 2 004 DHCP dynamic host configura tion pro tocol . A TCP/IP pro tocol tha t allows a serve r to assign a n IP add ress bas ed on a role nam e (hos t name) to a network node. differential input A type of input desi gn where two wire s (+ a nd -) ar e run from each signal source to the data a cquis ition inte rface.
Glossary 890USE177 00 April 2 004 177 EOS end of se gment. When m ore tha n one segment of I/O modul es is us ed in an islan d, an STB XBE 1000 EOS module is ins talled in the last posi tion in ev ery segme nt that has an ex tension followi ng it. T he EOS modul e extends island bus c ommunic ations to the nex t segmen t.
Glos sary 178 890USE17 700 April 2 004 function bl ock A function bl ock perfo rms a s pecific automati on func tion, su ch as speed control. A function block c ompris es confi guratio n data and a set of ope rating p arame ters.
Glossary 890USE177 00 April 2 004 179 I/O base A mounting de vice , designed to seat an Advantys STB I/ O modu le, hang it on a DIN rail, and c onnec t it to the islan d bus. It p rovid es the conne ction poi nt where the module c an receiv e eith er 24 VDC o r 115/23 0 VAC from the input or outp ut power bus distr ibuted by a PDM.
Glos sary 180 890USE17 700 April 2 004 industrial I /O An Advanty s STB I/O m odule des igned at a mod erate c ost for typ ical con tinuou s, high-duty -cycl e appl ications .
Glossary 890USE177 00 April 2 004 181 MAC ad dress media acce ss contro l addre ss. A 48-b it number, unique on a netwo rk, tha t is programme d into eac h netwo rk card or devic e when i t is man ufactur ed.
Glos sary 182 890USE17 700 April 2 004 NIM netw ork interfa ce mo dule. T his m odule is the in terface be tween an islan d bus and the fieldb us ne twork of which the i sland is a part. A NIM en ables all the I/ O on t he island to be trea ted as a singl e node on the fie ldbus .
Glossary 890USE177 00 April 2 004 183 PDM power di stribu tion modu le. A modul e that distr ibut es ei ther AC or DC field powe r to a cluster of I/O modules direct ly to its right on th e isl and bus. A PDM d elivers field power to the inp ut module s and the ou tput mo dules.
Glos sary 184 890USE17 700 April 2 004 proces s imag e A part of the NIM firm ware tha t serves a s a real -time data a rea for th e data exc hange process .
Glossary 890USE177 00 April 2 004 185 Rx reception . For example, in a C AN-based network, a PDO is describe d as an Rx PDO of the dev ice that re ceiv es it. SAP service ac cess point. The point at which the s ervic es of one com municati ons layer, as define d by th e ISO OSI reference m odel, is made avail able to th e next layer .
Glos sary 186 890USE17 700 April 2 004 siz e 2 base A mounting de vice, de signe d to se at an STB m odule, hang i t on a DI N rail, a nd connect it to th e isla nd bus. It is 18 .4 mm w ide and 1 28.25 m m high. siz e 3 base A mounting de vice, de signe d to se at an STB m odule, hang i t on a DI N rail, a nd connect it to th e isla nd bus.
Glossary 890USE177 00 April 2 004 187 STD_P standa rd profil e. On a Fipio network, a stand ard profi le is a fix ed set of conf igurati on and oper ating param eters fo r an agent devi ce, bas ed on the number of mo dules that the devic e con tains and the de vice ’s total d ata len gth.
Glos sary 188 890USE17 700 April 2 004 UDP user datag ram pro tocol. A c onnectio nless mode pro tocol in whic h messa ges ar e delivere d in a d atagram to a des tination compu ter. The UDP pro tocol is typicall y bundled wi th the I nternet Protocol (UPD/IP) .
C B A 890USE177 00 April 2 004 189 Numerics 10Ba se-T, 2 6 802.3 s tandard , 21, 27, 42 A ABL7 RE2403 Telefa st 24 VDC power suppl y, 41 action mo dule, 158 addr essa ble mo dule, 17, 46 , 47, 118, 1 .
Index 190 890USE17 700 April 2 004 E edit mo de, 50 , 53, 54 , 56 embedd ed web server access , 68 help, 67 managi ng, 111 navig ation , 68 overv iew , 19 proc ess ima ge, 116 produ ct su pport, 68 se.
Index 890USE177 00 April 2 004 191 island bus n ode ad dress address range, 29 setting , 60, 72 , 75 valid and inv alid addres ses, 29 island bus p assword, 16 4 L LEDs 10T AC T, 31 and COM S state s,.
Index 192 890USE17 700 April 2 004 R reboot o peratio n, 76, 84 refl ex ac tio n and fallba ck, 162 and the echo o utput data image area, 117, 120 , 169 overv iew , 156 refl ex bloc k typ es, 15 6 rem.
Index 890USE177 00 April 2 004 193 STB NIP 22 12, 92, 93, 1 00, 107, 109, 133 using t he Adva ntys STB LEDs , 31 using t he Ethern et LAN LEDs , 31 web- base d, 92 , 93, 94, 96 , 100 with th e Advanty.
Index 194 890USE17 700 April 2 004.
デバイスSchneider Electric 890USE17700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Schneider Electric 890USE17700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSchneider Electric 890USE17700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Schneider Electric 890USE17700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Schneider Electric 890USE17700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Schneider Electric 890USE17700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSchneider Electric 890USE17700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Schneider Electric 890USE17700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSchneider Electric 890USE17700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。