Schneider ElectricメーカーEM4800の使用説明書/サービス説明書
ページ先へ移動 of 32
PowerLogic TM Series EM4800 Multi-Circuit Meters Configuration Guide.
PowerLogic TM EM4800 Series 930-112-01-B.00 01/2011 © 2011 Schneider Electric All Rights Reserved Hazard Categories and Special Symbols Read these instructions carefully and look at the equ ipment to become familiar with the device befo re trying to install, operate, servi ce or maintain it.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 © 2011 Schneider Electric All Rights Reserved Copyright © 2011. Schneider Electric. All Rights Reserved.
PowerLogic TM EM4800 Series 930-112-01-B.00 01/2011 © 2011 Schneider Electric All Rights Reserved.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 Table of Con tents © 2011 Schneider Electric All Rights Reserved i Table of Contents POWERLOGIC CO NFIGURATION TO OL ......................... .............. ........... 1 System Set-up and Descripti on .
PowerLogic TM EM4800 Series 930-112-01-B.00 Table of Contents 01/2011 © 2011 Schneider Electric All Rights Reserved ii.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 1 POWERLOGIC CONFIGURATION TOOL This document describes how to configure the PowerLogic EM480 0 Series meter (PowerLogic EM483 3, EM4880 and EM4805 meters), using the PowerLogic configuration tool.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 2 Figure 1: Programmin g Switch locati on Table 1 lists the programming capabilitie s associate d with each parameter in combination with the programming switches.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 3 PPP password Configuration tool Configuration tool Immediate FTP use.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 4 Display Navigatio n The display on the front of the mete r pro vides status informa tio n for each circuit, and general information for metering.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 5 Communicatio ns Connecti ons If you are configuring the meter at the installation site, see the Po werLogic EM4800 Series Meter Installation Guide fo r instructio ns on connecting the power.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 6 7. Assign the PC a static IP address such that the first three segments are the same as the default IP address, and th e last segment is differe nt from the default IP address.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 7 7. Restore power. When control power i s restored, the meter will receive an IP address from a local DHCP server. This IP address can be viewed from the Diagnostics men u.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 8 Figure 3: Configuration t ool main wi ndow Connecting to a Me ter The configuration tool autom atically d etects and lists the Po werLogic meters on the same network segment as the PC .
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 9 Figure 4: Discovere d Units dialog bo x 2.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 10 Figure 6: Main con figuration wi ndow with configu red parameters Unit Field Configu rati on Tab Use Table 2 to set meter configuration parameters in the Unit Field Configuration tab.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 11 Table 2: Unit Field Confi gu rati on tab parameters Field Parameter Description Unit Field Configuration Current IP Address The current IP address for the unit .
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 12 Report Parameters The Report section in the main configurati on window has three tabs: • the Period tab allo ws the user to configure when the reports are generated and the interval at which data is collected.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 13 Figure 7: Period tab in the Report section Table 3: Period tab configura tion parameters Parameter Description Interval in Minutes The interval at which data is collected.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 14 Figure 8: Types tab in the Report se ction Table 4: Ty pes tab confi.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 15 Figure 9: Real Time In terv al tab in the Report section Table 5: Real Time Interval tab co nfiguration pa rameters Parameter Description Daily Enables daily re al time reporting by selecting the radial button.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 16 Figure 10: Power Fact or tab in the Report sect ion Table 6: Power Factor tab configuration p arameters Parameter Description Format You can set the display format to IEC or IEEE by selecting the radial button.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 17 Figure 11: BACnet tab in the Report section Table 7: BACnet tab co nfiguration parameters Parameter Description BACnet Device ID You can set the BACnet device ID by entering a 4-digit numeric ID.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 18 Manufacturin g Tab The Manufacturing tab allows the user to define the metering configuration for the PowerLogic meters.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 19 Meter Points (Circuits) Tab The Meter Points (Circuits) tab contains the configuratio n information for each of the metering points.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 20 To change the current rating for all meter points assigned to a meter: 1. Select a meter from the Meter Points (Circuits) List.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 21 Figure 14: Badg e Numbering pane.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 22 Pulse Probes Tab The Pulse Probes tab contains the c onfiguration information for each pulse input. It shows the measu rement type in units for each i nput, and the scale factor applied to th e collected puls e counts.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 PowerLogic configuratio n tool © 2011 Schneider Electric All Rights Reserved 23 Completing the Me ter Configuration Once you have defin ed all of the conf igurable para meters, the Po werLogic EM4800 Series meter is ready to be programmed.
PowerLogic TM EM4800 Series 930-112-01-B.00 PowerLogic configuration tool 01/2011 © 2011 Schneider Electric All Rights Reserved 24 2. Click Unit in the menu bar, then select Send from the drop -down menu to transmit the configuration setti ngs from your PC to the selected PowerLogic EM4800 Series meter.
930-112-01-B.00 PowerLogic TM EM4800 Series 01/2011 © 2011 Schneider Electric All Rights Reserved.
Electrical equipment should be instal led, oper ated, serviced, and maintained only by qualified personnel. No resp onsibility is assu med by Schneider Electric f or any consequences arising out of the use of this material.
デバイスSchneider Electric EM4800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Schneider Electric EM4800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSchneider Electric EM4800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Schneider Electric EM4800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Schneider Electric EM4800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Schneider Electric EM4800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSchneider Electric EM4800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Schneider Electric EM4800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSchneider Electric EM4800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。