SearsメーカーGR-051SFの使用説明書/サービス説明書
ページ先へ移動 of 14
SAFETY PRECAUTIONS 1. Check if an electric leakage occurs in the set. 2. When servicing current applying parts, unplug prior to servicing. 3. In case of testing with power injecting, wear rubber gloves to prevent electric shock. 4. If you use any appliances, check regular current, voltage and capacity.
In case that a considerable leakage occurs and to stop the vacuum pump will be necessary and add a small quantity of Freon to the system, if vacuum should not be obtained (pressure gauge can't fall to 1 atmosphere.), start the refrigeration unit and find the leakage with the special leak-finder.
AIR RECHARGING IN COMPRESSOR Test the refrigeration system by connecting it electrically before refilling operation. This is necessary to ascertain the function of the motor-compressor and identify the defects immediately.
In case that a considerable leakage occurs and to stop the vacuum pump will be necessary and add a small quantity of Freon to the system, if vacuum should not be obtained (pressure gauge can't fall to 1 atmosphere.), start the refrigeration unit and find the leakage with the special leak*finder.
SPECIFICATIONS ITEMS SPECIFICATIONS DOOR TYPE 1 DOOR NET CAPACITY 94 l CONDENSER TYPE WALL CONDENSER (FLUSH BACK) DEFROSTING SYSTEM MANUAL TEMPERATURE CONTROL KNOB DIAL ITEMS INSULATION DO_OR _ CABINE.
DISASSEMBLY A. DOOR 1. Loosen 3 screws holding an upper hinge to separate the door body. (Figure 7) Figure 7 B. THERMOSTAT 1. Pull Knob Dial, 2. Loosen 1 screw holding the case and pull it out to remove the Therme cover. (Figure 8) Figure 8 C. COMPRESSOR AND PTC 1.
CIRCUIT DIAGRAM 4 THERMOS'[A'T YL _ BK GN{GN_L) t <_ BK s_ it"__FL _REs_oR P.T.C STARTER YL: YELLOW BK: BLACK BL: BLUE GN:GREEN THE PLUG TYPE ON CIRCUIT DIAGRAM IS SUBJECT TO CHANGE IN DIFFERENT LOCALITIES.
TROUBLESHOOTING DEFECT EFFECT CAUSE REMEDY GROUP PARTIALLY OR COMPLETELY OUT OF REFRIGERANT CHARGE EXCESSIVELY FULL HUMIDITY IN THE SYSTEM PRESENCE OF AIR IN THE SYSTEM BLOCKED CAPILLARY MOTOR- COMPRE.
NO COOLING The Compressor doesn't run, Check if the current flows at the contacting Poor contacting point Replace the Thermostat. Check if the current flows at the contacting point of the starting system. Poor contacting point and broken Replace the device.
COMPRESSOR AND ANOTHER ELECTRIC COMPONENTS Separate the PTC-STARTER from the Compressor and measure the voltage between M and C of the Compressor. Equal to the applied _ r_ voltage. (Rating _ 2> voltage + 10%) I Check the L resistance of the Compressor Motor.
PTC Poor starting or no operating of the Compressor. 4D First, separate the PTC from the Compressor and check the voltage between NO 5 and 6 in the PTC with a muititester or Wheatstone Bridge. F Normal _ Check another electric components. __ Abnormal _ Replace the PTC.
EXPLODED VIEW -14-.
-15-.
HOME DEPOT(HDP) Electrical Specification ITEM GR-051SF GR-131SF GR=151SF BUYER MODEL NAME GR_051SF GR_131SPF GR-151SPF RATED INPUT(W) 70+15% 70+15% 70+15% DEFROST INPUT(W) ENERGY CONSUMPTION(kwh/yr) 288 330 350 AMPERE(Amp) 0.84 1.0 0.7 RATING(V/Hz) 115/60 115/60 115/60 REFRIGERANT R134a R134a R134a CHARGE(Oz) 1.
デバイスSears GR-051SFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sears GR-051SFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSears GR-051SFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sears GR-051SFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sears GR-051SFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sears GR-051SFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSears GR-051SFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sears GR-051SFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSears GR-051SFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。