SharkメーカーV1315の使用説明書/サービス説明書
ページ先へ移動 of 18
REPLACEMENT PAR TS HOUSEHOLD USE ONL Y IMPORT ANT SAFETY INSTRUCTIONS NAME OF EACH P ART PREPARA TION BEFORE USE USING THE VACUUM CLEANER USING THE A TTACHMENTS EMPTYING THE DUST COMP ARTMENT CLEANING.
IMPORT ANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following. READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER WARNING - T o reduce the risk of fire, electric shock or injury: 1.
Note to user concerning attachment plug: 2 16. Do not touch the agitator while it is spinning. 17. Do not place any heavy items on top of the vacuum cleaner. 18. Do not step on the hose or pull it too strongly . 19. Do not pick up items such as pieces of waste paper or cloth which look as though they may cause the hose to become blocked.
Set the O N/OFF switch to " ON " to light the headlight. 3 NAMES OF EACH P ART W ARNING: Operate vacuum cleaner only at the voltage specified on name plate.
Caution : Do not connect the power cord plug to the wall outlet until assembly is completed. Attaching the handle PREP ARA TIONS BEFORE USE Attaching th e suction hose A & attachments 4 1 2 Set the vacuum cleaner to the upright position. lnsert the handle as shown in the illustration.
RELEASING THE POWER CORD Secure the power cord plug on the power cord. WARN ING: T o re duce the risk of e lectric shock, this appliance ha s a polarized plu g (o ne b lade is w ider than the other). This plug will fit in a po larized outlet only one way .
ON/OFF Switch 6 USING THE V ACUUM CLEANER ON/OFF SWITCH Start or st op va cuum cleaner by pushing on the swi tch. ADJUSTING THE HANDLE Upright po sition The handle is normally locked in this The handle of this vacuum cleaner can be set to one of three positions -Upright, Normal, Parallel.
1 2 RUG/FLOOR (T OOLS)SELECT OR The RUG/FLOOR(TOOLS)selector should only be adjusted while the vacuum cleaner is turned on and in the upright position. When cleaning a rug or carpet,first turn the ON/OFF switch to the ON position,and then set the RUG/ FLOOR(TOOLS)selector to the RUG position.
Caution: When using one of the attachments during cleaning,set the vacuum cleaner to the upright position. 1 2 3 USING THE A TT ACHMENTS Press the release button C to disconnect the handle from the vacuum cleaner . Remove the attachments from the vacuum cleaner.
1 3 2 4 1 2 1 3 2 4 1 2 Trapdoor Projection Groove Release Lever Duster Knob Turn the duster knob several times in the direction shown to empty the dust compartment. EMPTYING THE DUST COMP ARTMENT Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before cleaning.
Remove the dust compartment.(refer to page 9) Clean the filter fins free of dirt with the forked end of cleaning utensil as shown. Prefilter Dust Compartment Ribs Main Filter 1 1 CLEANING THE FIL TERS 2 Set the dust compartment to the parallel position.
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect Cleaning the agitator assembly 1 2 3 CLEARING BLOCKAGES AND CLEANING THE A GIT A T OR ASSEMBL Y the power cord from the wa ll outlet before clearing any blockages in the suction hose and cleaning th e agitator assembly .
REPLACING THE HEADLIGHT LAMP REPLACEMENT INSTRUCTIONS Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below . 1 Set the vacuum cleaner to the parallel position.
Place a new flat belt onto the motor shaft and pulley. 1 2 3 4 5 Bearing Holder Groove Nozzle Head REPLACEMENT INSTRUCTIONS Caution: Be sure to turn the O N/OFF swit ch to the"OFF" position a nd dis connect the po wer cord fro m the wall outlet before replacing an y of the parts be low .
14 2 4 1 3 1 2 3 REPLACEMENT INSTRUCTIONS REMOVING THE BOTT OM PLA TE Set the vacuum cleaner to the parallel position and turn it over . Slide the latch in the direction of the arrow.
Caution: Be sure that seal on the HEPAfilter is inserted towards the inside of the vacuum cleaner. The filter cover should be correctly oriented when it is reattached. Do not reattach it upside down. 3 Insert a new HEPAfilter with the seal to the inside of the vacuum cleaner.
9BF-D-P11 1-00721 0304- If there is a problem with the vacuum cleaner, carry out the following checks to find the cause. If the problem still persists after the checks have been made, do not use the vacuum cleaner to prevent the possibility of an accident occurring.
Model V1315 ONE (1) YEAR LIMITED WARRANTY EURO-PRO Operating LLC warrants this p roduct to be fr e e from defects in material and workmanship for a period of one (1) year from the date of the original purchase. This warra nty applies only to normal domestic household use.
デバイスShark V1315の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Shark V1315をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはShark V1315の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Shark V1315の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Shark V1315で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Shark V1315を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はShark V1315の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Shark V1315に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちShark V1315デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。