R FU-440E FRANÇAIS ENGLISH DEUTSCH ESPAÑOL ITALIANO Free standing type Freistehende A usführung T ype mobile Tipo vertical sin soporte Modello strutturalmente indipendente Vrijstaand type ‚ÍÎÓ.
.
ENGLISH FEA TURES Plasmacluster Ion Control The unit controls the ratio of negative ions and positive ions depending on the con- dition of the room. • Clean Mode Approximately the same numbers of posi- tive and negative ions are discharged. This mode is effective for reducing some airborne mold.
IMPORT ANT SAFETY INSTRUCTIONS E-2 When using electrical appliances, basic safety precautions should be followed, including the following: W ARNING - T o reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the air purifier .
ENGLISH INST ALLA TION GUIDELINES • During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipments.
QUICK CLEAN operation Indicator Light P ART NAMES MAIN UNIT DISPLA Y Filter Indicator Light OFF Timer Display Indicator Lights Odor Sensor Remote Control Receiver CLEAN-SIGN Light E-4 Fan Speed Indica.
ENGLISH E-5 Battery Information • The battery life is about 1 year . • The batteries for this remote control are for initial use only . Change the batteries when necessary . • Incorrect usage of the batteries may cause battery fluid leakage and/or damage.
PREP ARA TION To maintain the quality of the filters, they are installed in the main unit within plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 1 Remove the filters 1 Remove the Front Panel. Pull the bottom of the Front Panel.
ENGLISH E-7 outlet. 2 Install the filters 1 Place the HEP A Filter within the Filter Frame with the tabs facing up. Do not install the filter backwards or the unit will not operate properly . 2 Place the Active Carbon Filt e r on top of the HEP A Filter with the bands (2 places) facing up.
OPERA TION MAIN UNIT OPERA TION Plasmacluster Indicator Light MODE Selection Button E-8 Power ON/OFF Button AUT O operation The fan speed is automatically switched (HIGH*, MEDIUM, SILENT) depending on the amount of impurities in the air . The sensors detect the impurities for efficient air purification.
ENGLISH DETERMINING THE BASE IMPURITY RA TE For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the conditions of the air . If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash in green, orange and red.
1 hour Cancel 4hours 8 hours Plasmacluster AUTO When pressed, the unit will switch between Clean Mode and the Ion Control Mode automatically de- pending on the amount of impurities in the air as detected by the dust and odor sensors. Clean Mode will operate for 1 minute when the Auto func- tion is selected.
ENGLISH CARE AND MAINTENANCE To maintain optimum performance of this air purifier , please clean the unit including the sensor and filters periodically . When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands.
E-12 CARE AND MAINTENANCE W ASHABLE ACTIVE CARBON FIL TER CARE 1 Fill a large container with warm water , add a mild kitchen detergent and stir . Dilute as indicated on the detergent container . HAND W ASH ONL Y! DO NOT TUMBLE DR Y! Care Cycle When the Filter Indicator Light lights up, this indicates that the filter needs to be cleaned.
ENGLISH FIL TER REPLACEMENT GUIDELINES Depending on the usage environment, air outlet odor may become strong after several months. If dust or odors cannot be removed easily , replace the filters.
TROUBLESHOOTING E-14 Before calling for repair , please review the list below , since the problem may not be a unit malfunction. SYMPT OM REMEDY (not a malfunction) The Remote Control does not work .
ENGLISH SPECIFICA TIONS E-15 Model Power supply Fan speed level Rated power Air Flow V olume Applicable floor surface Cord Length Dimensions W eight Fan Speed Operation 220-240V 50/60Hz ~31m 2 * 2.5m 415mm(W)x200mm(D)x585mm(H) 6.7kg MAX 32 W 240 m 3 /hour MEDIUM 9 W 120 m 3 /hour SILENT 3.
A. Information on Disposal for Users (priv ate households) 1. In the European Un ion Attention: If you w ant to dispose of this equip ment, please do not use the ordinary dust bin! Used electrical a n.
SER VICE PROCEDURE / SER VICE VORGEHENSWEISE SER VICE PROCEDURE - ONL Y EFFECTIVE IN GERMANY Dear SHARP customer , SHARP machines are proprietary articles which are produced with precision and care according to most modern production methods.
デバイスSharp FU440Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharp FU440Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharp FU440Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharp FU440Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharp FU440Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharp FU440Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharp FU440Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharp FU440Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharp FU440Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。