R-21JCA-F In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used.
R-21JCA-F PRECA UTIONS T O BE OBSER VED BEFORE AND DURING SER VICING T O A V OID POSSIBLE EXPOSURE T O EXCESSIVE MICR O W A VE ENERGY (a) Do not operate or allow the oven to be operated with the door open.
R-21JCA-F 1 W ARNING T O SER VICE PERSONNEL Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock.
R-21JCA-F 2 MICR O W A VE MEASUREMENT PR OCEDURE A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exce.
R-21JCA-F 3 SHARP ELECTRONICS CORPORATION SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SER VICE MANU AL LIGHT DUTY COMMERCIAL MICROWAVE OVEN R-21JCA-F FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVENS, R-21JCA-F.
R-21JCA-F 4 3-Pronged Plug Grounded Receptacle Box Grounding Pin 3-Pronged Receptacle ITEM DESCRIPTION Power Requirements 120 Volts 14 Amperes 60 Hertz / Single phase, 3 wire grounded Power Output 100.
R-21JCA-F 5 OVEN DIAGRAM 1. Back splash cover 2. Side splash cover 3. Oven light 4. Ceramic shelf 5. Control panel 6. Cavity face plate 7. Door latch openings 8. Door latches 9. Door hinges 10. Door seals and sealing surfaces 11. Door handle 12. Oven door with see-through window 13.
R-21JCA-F 6 OPERA TION DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.
R-21JCA-F 7 Figure O-2 Oven Schematic-Microwave cooking Condition NOTE: Indicates components with potential above 250 V. Figure O-1 Oven Schematic-OFF Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. LIGHT UP DIAL OFF. 2. DOOR CLOSED. SCHEMATIC NOTE: CONDITION OF OVEN 1.
R-21JCA-F 8 DESCRIPTION AND FUNCTION OF COMPONENTS DOOR OPEN MECHANISM The door is opened by grasping the door handle, refer to Figure D-1. When the door handle is grasped, the handle lever is pulled. And then the upper and lower latch heads are moved upward by the handle lever, and they are released from the latch hook.
R-21JCA-F 9 TR OUBLESHOO TING GUIDE Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected. When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks.
R-21JCA-F 10 A MAGNETRON ASSEMBLY TEST TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit.
R-21JCA-F 11 TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open.
R-21JCA-F 12 TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.
R-21JCA-F 13 TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST J CONTROL PANEL ASSEMBLY TEST WARNING : To prevent an electric shock do not touch the electrical parts and the printed wiring board. Because the control unit is "TRANSLESS CIRCUIT" and many electrical parts are used at A.
R-21JCA-F 14 TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 6) After that procedure, re-connect the power supply cord. 1. Control Panel The following symptoms indicate a defective control unit. 1-1 In connection with LEDs a) At a certain LED, all or some LEDs do not light up.
R-21JCA-F 15 TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB, this foil pattern acts as a fuse. 1. Foil pattern check and repairs. 1) Disconnect the power supply cord and then remove outer case.
R-21JCA-F 16 DESCRIPTION OF LSI LSI The I/O signal of the LSI is detailed in the following table. T OUCH CONTROL P ANEL ASSEMBL Y OUTLINE OF TOUCH CONTROL PANEL Control Unit Control unit consists of LSI, power source circuit, synchroniz- ing signal circuit, reset circuit, buzzer circuit, encoder circuit and indicator circuit.
R-21JCA-F 17 9 RESET IN Auto clear terminal. Signal is input to reset the LSI to the initial state when power is applied. Temporarily set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter set at "H" level.
R-21JCA-F 18 1. Precautions for Handling Electronic Components This unit uses CMOS LSI in the integral part of the circuits. When handling these parts, the following precautions should be strictly followed. CMOS LSI have extremely high impedance at its input and output terminals.
R-21JCA-F 19 PRECAUTIONS FOR USING LEAD-FREE SOLDER 1. Employing lead-free solder The "Main PWB" of this model employs lead-free solder. This is indicated by the "LF" symbol printed on the PWB and in the service manual. The suffix letter indicates the alloy type of the solder.
R-21JCA-F 20 POWER TRANSFORMER REMOVAL To remove the outer case, proceed as follows. 1. Disconnect the power supply cord. 2. Open the oven door and block it open. 3. Remove the five (5) screws from rear and along the side edge of case. 4. Slide the entire case back about 3cm to free it from retaining clips on the cavity face plate.
R-21JCA-F 21 HIGH VOLTAGE RECTIFIER ASSEMBLY AND HIGH VOLTAGE CAPACITOR REMOVAL To remove the components, proceed as follows. 1. Disconnect the power supply cord and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor.
R-21JCA-F 22 Side View Rear View Shaft Table Center of bracket Gap Rotor Bracket Stator Groove joint pliers Coil Shaft Axis Stator Rotor These are the positions that should be pinched with pliers COOLING FAN MOTOR REMOVAL POSITIVE LOCK ® CONNECTOR (NO-CASE TYPE) REMOVAL Figure C-2.
R-21JCA-F 23 Removal 1. Disconnect the power supply cord and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Remove the one (1) screw holding the green wire to the cavity rear plate. 5. Disconnect the wire leads of the power supply cord from the noisew filter.
R-21JCA-F 24 CHOKE COVER 1. Disconnect the power supply cord. 2. Open the door slightly. 3. Insert a putty knife (thickness of about 0.5mm) into the gap between the choke cover and door frame as shown in Figure C-6 to free engaging parts. 4. Pry the choke cover by inserting a putty knife as shown in Figure C-6.
R-21JCA-F 25 (B) An approved microwave survey meter should be used to assure compliance with proper microwave radiation emission limitation standards. (Refer to Microwave Measurement Procedure.
R-21JCA-F 26 1. Disconnect the power supply cord. 2. Open the door and block it open. 3. Make sure that the smooth surface of the ceramic shelf face up. 4. Make sure that the rubber packing without a fin of the ceramic shelf faces the front of the oven.
R-21JCA-F 27 6 45 1 2 3 6 45 1 2 3 A B C D E F G H A B C D E F G H Figure S-1. Pictorial Diagram FUSE RED BLK L N WHT RED WHT WHT ORG GRY THERMAL CUT-OUT 125˚C(OVEN) OVEN LAMP & SOCKET THERMAL CUT-OUT 145°C(MAG.) FAN MOTOR WHT ORG WHT RED WHT HIGH VOLTAGE COMPONENTS MAGNETRON H.
R-21JCA-F 28 Figure S-2. Control Panel Circuit 6 45 1 2 3 6 45 1 2 3 A B C D E F G H A B C D E F G H INT0 N.F VDD VSS XIN XOUT CNVSS RESET D3 D4 D5 D6 D7 P20 P21 P22 A B C D4 ICP 1 C2 C3 Q1 R1 R2 Q2 R5 1K POWER TRANSFORMER D70 D71 D72 D73 DOOR SENSING SWITCH 0.
R-21JCA-F 29 6 45 1 2 3 6 45 1 2 3 A B C D E F G H A B C D E F G H Figure S-3. Printed Wiring Board JP38 JP39 JP30 JP36 D71 D76 D78 D74 D70 D80 D72 D81 D77 D73 JP34 JP31 JP23 JP22 JP21 JP5 R11 RY2 RY1.
R-21JCA-F 30 ∆ ∆ * * * ∆ * PA R TS LIST Note: The parts marked “ ∆ ” may cause undue microwave exposure. The parts marked “*” are used in voltage more than 250V.
R-21JCA-F 31 ∆ ∆ ∆ ∆ ∆ ∆ ∆ REF. NO. PART NO. DESCRIPTION Q'TY CODE 4-34 PSPA-A112WRE0 Mica washer 1 AC 4-35 PCUSGA378WRP0 Cushion 1 AL 4-36 PCUSUA507WRP0 Cushion 1 AC 4-37 PCUSUA517.
R-21JCA-F 32 6 45 1 2 3 6 45 1 2 3 A B C D E F G H A B C D E F G H OVEN AND CABINET PARTS 7-3 7-3 7-12 1-13 6-4 1-1 7-7 4-15 4-15 1-8 7-7 4-33 7-4 7-1 7-1 7-4 1-11 1-15 4-3 4-4 4-5 1-3 1-5 7-5 4-35 4-.
R-21JCA-F 33 6 45 1 2 3 6 45 1 2 3 A B C D E F G H A B C D E F G H CONTROL PANEL PARTS DOOR PARTS MISCELLANEOUS 3-2-2 3-3 3-2-1 3-2 3-1 3-5 3-5 3-4 Actual wire harness may be different from illustration.
R-21JCA-F 34 '05 SHARP CORP. (10S0.80E) Printed in U.S.A COPYRIGHT © 2005 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in retrieval systems, or.
デバイスSharp R-21JCA-Fの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharp R-21JCA-Fをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharp R-21JCA-Fの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharp R-21JCA-Fの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharp R-21JCA-Fで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharp R-21JCA-Fを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharp R-21JCA-Fの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharp R-21JCA-Fに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharp R-21JCA-Fデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。