SierraメーカーVSP 3001の使用説明書/サービス説明書
ページ先へ移動 of 25
SIERA ELECTRONICS SOUND & SECURITY IP CAMERA INSTRUCTION MANUAL www .sieraelectronics.com SIERA ELECTRONICS SOUND & SECURITY VSP 3001 IP CAMERA.
Warning: Please read this manual carefully before using. Complete package should include the following items: AC adaptor 1 pc category 5 cross cable 1 pc I/O terminal cable 1 pc instruction 1 pc manua.
1 Introduction 2 1.1 technology support 1.2 system requirements 2 Panel description 3 2.1 front view 2.2 rear view 3 Installation 4 3.1 cautions 3.2 step 4 Illustration for net connection 5 4.1 onnect with PC directly by category 5 cable 4.2 connect to INTRANET through HUB/Switch 4.
1.1 Features Built-in web server , high quality JPEG image can be displayed through Internet browser upon connection with Ethernet. Motion JPEG can be up to 15 frames per second with high resolution 640x480. Through Internet, pan/tilt heads and lens can be conveniently controlled to meet with long-range monitoring.
3 2.1 Front view Lens Power indicator 2.2 Rear view Ethernet indicator I/O connector DC in jack 2 P ANEL DESCRIPTION Ethernet port.
3 INST ALLA TION 4 3.1 Cautions Please read all safety instructions carefully before installation. VSP-3001 IP camera should installed indoors generall y . The prolonged exposure under the sunlight or other strong lights shall accelerate the aging of the shell and shorten the using term.
4 ILLUSTRA TION FOR NET CONNECTION 5 He common connection programs for VSP-3001 network camera: 4.1 Connecting directly to PC(through category 5 cross cable) For this program, the page browsing requires the basic configuration as below for PC and IP camera: A Connect correctly with the IP camera as above illustration.
6 4.3 Connecting to Internet through HUB/Switch/Router For this program, not only the basic setup of PC and IP camera but also the setup of Port Forwarding function of Router is required, so the visit for network camera besides Intranet is accessible.
7 5 IP CAMERA P AGES 5.1 Home page There are 3 options on home page: 1) image browsing (single camera screen/multi camera screen) 2) configuration 3) help 5.
8 Enter user name and password of administrator and general user, then following dialogue box appears: click left operation bars to adjust the image directly: Brightness 17 levels Resolution 640 480 320 240 160 120 Quality favor clarity standard favor motion Image size x1 x2 5.
9 Enter user name and password of administrator, then setup page appears. network set up network parameters time set up date and time administrator set up user name and password of administrator gener.
10 5.4 N etwork Name of network camera 4-15 English characters and 2-7 Chinese characters Port no Assign IP address Assign DHCP Gateway Network camera management server Notes: please restart after click save to effect the settings you entered. The range is 1-65535(default:80).
11 5.5 Time item description settings remarks 1.current date and time (1) have the same time with PC (2) input by handwork yyyy-mm-dd for year 1970 to 2039. hh:mm:ss for 24h mode. Display current date and time of IP camera. Adjust internal clock T ake the internal clock of network camera with the same time of the PC.
12 5.6 Administrator [Authentication] [None]: anyone can access all pages. [administrator only]:for setup page [administrator]for setup page and [general user] for viewer page [user name and password]:user name should be 4-15 English words or 2-7 Chinese characters.
13 5.8 Image settings [brightness adjust] :17 levels, control the function for brightness adjustment. [Header display] : display the name of network camera and time on image or not. [Power line frequency] : 50HZ and 60HZ optional. Select correct power frequency and prevent fluorescent light interfering the image.
14 5.10 A larm trigger The alarm mode means the transmission of pre and/or post alarm images held in the buffer to specified address. Alarm: select enable to confirm the alarm mode function. [Alarm occur condition] : the alarm is subject to the rising or falling of voltage detected by the I/O connector.
15 Item Description Remarks IP address or host name of FTP server port number FTP method login ID Password upload file path over write setting 1 65535 Should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ]. [FTP transfer] Start with / and end with / , Root directory: / (default).
16 5.11 Transfer image in the timer mode Timer mode means sending images to specified address when the clock reaches the pre-assigned time. [Timer] : select the function of transferring image in the timer mode or not. [Timer setting] : 8 timers is optional.
17 5.12 Background recording function Background recording means sending images to background FTP server for recording at specified intervals. [Record] : select the background recording function or not. [Image setting] : select the parameters of the image recorded in background.
18 6 RECORDING FUNCTION 6.1 Activex control recording ActiveX control recording function is for IE browser only, and can not for Netscape Navigator browser. Please right-click the mouse at the image and select the recording setting in the option box appeared when browsing.
19 7 I/O DESCRIPTION 7.1 About I/O The I/O connector controls input and output of signal, and it includes 1 I/O input terminal, 1 I/O output terminal and 1 RS-232 converter or half duplex RS-485 port. Port description: Port Name Description 1 AGND analog ground 2 485B/RXD 3 485A/TXD 4 DGND digital ground 5 +12V max.
20 Appendix 1: Reset to factory default In some case, we need reset the server to factory default which can operate on Setup Page. If the user can not login the Setup Page(such as forgetting the user name and the password), it will be available for resetting to factory default through ARP and PING to re-assign the IP address.
21 Display as below: C:>arp -d C:>arp -s 192.168.1.61 00-0c-e8-00-00-01 C:>ping -t 192.168.1.61 Pinging 192.168.1.61 with 32 bytes of data: Request timed out. Request timed out. Request timed out. Reply from 192.168.1.61: bytes=32 time=5ms TTL=255 Reply from 192.
22 Appendix 2: Troubleshooting can not access the network camera via browser the problem of Ethernet connection Please check the VSP-3001 network camera, the Hub, the Switch and Ethernet indicator. Check their connection if there is any abnormity. Disconnect the Ethernet connection, perform PING.
23 Appendix 3: Specification Hardware 100 levels are optional Brightness NTSC/PAL: 640x480, 320x240, 160x120 Ethernet(10 Base-T) TCP/UDP/IP , ARP , ICMP , HTTP , TFTP , T elnet, SMTP max.
デバイスSierra VSP 3001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sierra VSP 3001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSierra VSP 3001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sierra VSP 3001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sierra VSP 3001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sierra VSP 3001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSierra VSP 3001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sierra VSP 3001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSierra VSP 3001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。