Document No. 14811 January 2005 DA5320 8-CHANNEL AES AUDIO MIXER/ ROUTER MODULE.
14811 • January 2005 • Front Matter Page ii.
14811 • January 2005 • Front Matter Page iii SIGMA ELECTRONICS's products are certified to comply with the regulations and recommendations of several certifying agencies. For complete details, as well as copies of the certification documents, please visit our website at www.
14811 • January 2005 • Front Matter Page iv CUSTOMER APPRECIATION STATEMENT SIGMA ELECTRONICS would like to take this opportunity to compliment you on your intelligent selection of high-quality audio or video equipment. It is our goal to provide the highest quality products and unparalleled service to all of our valued customers.
14811 • January 2005 • Introduction/overview Page 1 INTRODUCTION/OVERVIEW The multi-function Sigma DA5320 8 Channel Mixer/Router module is a member of the Sigma 5000 series OctaStream ™ product line.
14811 • January 2005 • Receiving Inspection and Unpacking Page 2 RECEIVING INSPECTION AND UNPACKING By the time you have found and opened this manual, you have already begun to unpack the shipping container.
14811 • January 2005 • System Components Page 3 SYSTEM COMPONENTS Frame The DA5320 module is engineered to operate in a Sigma S5000 Signal Management Frame. This frame provides all the necessary interface components and power for opera- tion of the DA5320 module.
14811 • January 2005 • Module Installation/Removal Page 4 MODULE INSTALLATION/REMOVAL The DA5320 may be installed in any module slot in a S5000 Signal Management System frame.
14811 • January 2005 • Module Installation/Removal Page 5 RP303 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 RP302 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 A B C D E F G H I J OCTABUS OUTPUT OCTABUS I.
14811 • January 2005 • Operation Page 6 OPERATION Front Panel Controls/Displays The front panel, shown below, has three distinct functional areas - the Indicator LED’s under the OctaStream logo on the right side; the switch controls, mostly on the left side and the 7-segment display in the middle.
14811 • January 2005 • Operation Page 7 CONTROLS SELECT BUTTON The Select button is used to progress to a lower menu level. If pressed repeat- edly, the display will always return to the idle display (see below) without making any changes to any menu items .
14811 • January 2005 • Operation Page 8 Display Activation To access menus when the Idle Display is showing, press any button. Status Check To check the current status of any parameter, activate the menu display and navigate through the menu to the edit screen for the parameter of interest.
14811 • January 2005 • Operation Page 9 Configurable Parameters/Menu Items Note: What follows is a discussion of the configurable parameters in the DA5320. To view a diagram of the flow of the menu structure with simple operating instructions, see the section of the manual entitled MENU STRUCTURE that follows this discussion.
14811 • January 2005 • Operation Page 10 sent to the ouput may be adjusted immediately prior to being sent to the output connector. These features are detailed in the Output Channel Assignment/Mixing/Gain Control section below. The DA5320 has two additional features that are available to the user to assist in providing quality I/O routing.
14811 • January 2005 • Operation Page 11 Output Channel Assignment/Mixing/Gain Control The sub-menu item is used to configure the routing matrix of defined inputs to spe- cific physical output connectors and the mixing operation of the DA5320. It is located under the main menu item.
14811 • January 2005 • Operation Page 12 any valid NTSC or PAL video signal or AES Digital Audio. The DA5320 will match its ouptut signal timing to be synchronized to this reference. To have the DA5320 match its output signal timing to the internal reference the menu setting must be set to ON.
14811 • January 2005 • Operation Page 13 N on -V olatile C onfiguration P arameter S torage All configuration data can be stored in the FlashROM to preserve it in the event of a loss of power. On power-up, all settings will be returned to their previous settings.
14811 • January 2005 • Menu Structure Page 14 MENU STRUCTURE The following graphic display of the menu structure is provided to give the user an overall view of the commands that are accessible via the front panel controls. Detailed explana- tions of each parameter have been provided above.
14811 • January 2005 • Menu Structure Page 15 Note: around character indicates character will be blinking - data entry mode active ..
14811 • January 2005 • Menu Structure Page 16 SAVE CONFIG TO FLASH DIAGNOSTICS (Status Only) RESET Reset Board Reset All Reset Outputs Reset Inputs Current ON/OFF setting shown.
14811 • January 2005 • Menu Structure Page 17 NOTES.
デバイスSigma DA5320の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sigma DA5320をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSigma DA5320の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sigma DA5320の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sigma DA5320で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sigma DA5320を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSigma DA5320の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sigma DA5320に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSigma DA5320デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。