SMC NetworksメーカーEtherNet/IP EX500-GEN1の使用説明書/サービス説明書
ページ先へ移動 of 23
Reduced wiring system EX500 - GEN1 Instruction Manual EtherNet/IP™ Compatible GW Unit Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA.
Thank you for purchasing the SMC reduced wiring system EX500 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference.
2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.
4 5 SAFETY ( continued ) Follow the instructions given below when handling your reduced wiring system. Otherwise a damage or failure to cause a malfunction can result. Operate the reduced wiring system at the specified voltage. Reserve space for maintenance.
6 7 EX500 P art Names Communication connector 1 2 3 4 5 6 7 8 Note1 : For wiring method, refer to subsection "Wiring" ( page 11 ) of section "EX500" in this manual. Note2 : For display and setting method, refer to subsection "Display/Switch Setting" ( page 18 ) of section "EX500" in this manual.
8 9 Specification Basic specifications Rated voltage 24VDC Range of power supply voltage Power supply for input and controlling GW/SI : 24VDC 10% Power supply for output : 24V DC+10% /- 5% ( Voltage drop warning at around 20V ) Rated current Power supply for input and controlling GW/SI : 3.
10 11 Wiring Specification ( continued ) The wirings is explained in the following order. Communication wiring : Connection with EtherNet/IP Po wer supply wiring : Connections of power supplies f or s.
12 13 Wiring ( continued ) Communication wiring Aligning the key groove with the communication connector ( 4-pin, socket ) of GW unit, plug the Ethernet communication cable ( plug ). Tighten the lock nut on cable side by turning it clockwise by hand. Confirm that the connector portion does not move.
24VDC 24VDC Brown : 0V ( for solenoid valves/output ) White : 24VDC ( for solenoid valves/output ) Gray : Ground ( PE ) Blue : 0V ( for input and controlling GW/SI ) Black : 24VDC ( for input and controlling GW/SI ) Cable Part No.
16 17 Wiring (continued ) For GW unit – Manifold v alve – Input unit manifold configuration Two communication connectors in SI unit and one communication connector in Input unit are installed respectively. To the communication connector ( C2 ) or ( 1 ) of SI unit, connect the branch cable with M12 connector from GW.
GATEWAY UNIT EX500 SERIES COM A COM B COM C COM D LAN NS MS 100 LINK PWR 18 19 Display/Switc h Setting Display NOTE When connecting manifold valve only without connecting Input unit manifold, LEDs of COM A to D do not light. To make them light, connect a terminal plug to the unused connector of SI unit ( "C1" or "0" ).
21 20 SI Unit P art Names The SI unit is the unit to communicate with GW unit in combination with manifold valve. It can be used with SV series valves and VQC series valves. In addition, this unit is able to operate solenoid valves, relays. etc. in combination with EX9 series general purpose output block.
23 22 Mounting/Wiring The mounting and removing methods of SI unit are as shown below. For branch wiring method, refer to subsection "Wiring" ( page 15 ) of section "EX500" in this manual.
25 24 Display Power LED Communication LED SI unit for SV series v alves ( EX500-S 01 ) Power LED Communication LED SI unit for VQC series valves ( EX500-Q ) Power LED Lights on : Power to solenoid valves/output is supplied at the specified voltage. Lights off : Power to solenoid valves/output is not supplied at the specified voltage.
27 26 Dimensions ( unit : mm ) When only input bloc ks for M8 connector are connected 44.2 39.7 L3 (L4) 5 L1 L2 ( Rail mounting pitch: 12.5 ) DIN Rail 35 49 32.2 (7.5) When only input bloc ks of 8-point-integrated type are connected L1 [mm] : Rail length L2 [mm] : Mounting pitch L3 [mm] : Manifold length L4 [mm] 98 110.
29 28 Specification Specifications for Input unit Connected block Current source type input block ( PNP input block ) or Current sink type input block ( NPN input block ) Connected block station Max. 8 blocks Supply voltage for block 24VDC Supply current for block Current consumption 0.
31 30 Correspondence between input number and input bloc k Input block up to 8 can be connected ( 16 points ). Input numbers are 0 to 15 from Input unit side. 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 2468 10 Input unit 12 14 13579 11 13 15 Display Power LED Indicator LED Power LED Lights on : Power for input and controlling GW is supplied.
33 32 2. EX9-PE1 VQC series SI unit for general purpose output block ( EX500-Q 02 ) Dimensions ( unit : mm ) 21.2 59.8 72.6 21 26.7 22.2 43.2 1. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 21.2 59.8 80.3 22.2 43.2 21 26.7 PWR PWR 2. EX9-PE1 Power supply connector 1 Unused Power input connector 2 Supplies power for output devices.
35 34 Wiring Output wiring Connect output devices to the output connectors. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 output connectors M12, 5-pin, socket NOTE Mount a waterproof cap to each unused connector. The proper use of waterproof cap can achieve IP65 Enclosure.
37 36 M12, 5-pin, reverse key, socket Po wer supply wiring When combining EX9-OEP1 ( or EX9-OEP2 ) and EX9-PE1 and using external power supply, connect the power supply to the power input connector of EX9-PE1. When selecting power supply, refer to "Handling precautions" ( page 3 ) in this manual.
39 38 Display 1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2 0 Lights on : Output ( OUT 0 ) is ON. Lights off : Output ( OUT 0 ) is OFF. 1 Lights on : Output ( OUT 1 ) is ON. Lights off : Output ( OUT 1 ) is OFF. Display Description PWR PWR 2. EX9-PE1 PWR Lights on : Power is supplied from external power supply.
41 40 NOTE Tighten the waterproof cap by the specified tightening torque. ( 0.05N m for M8, 0.1N m for M12 ) Waterproof cap Mounted on unused ports of GW unit, input block, power block and output block. The proper use of this waterproof cap can achieve IP65 Enclosure.
43 42 MS LED status Normal status : Lit in green Fatal failure : Lit in red 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch.
デバイスSMC Networks EtherNet/IP EX500-GEN1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SMC Networks EtherNet/IP EX500-GEN1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSMC Networks EtherNet/IP EX500-GEN1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SMC Networks EtherNet/IP EX500-GEN1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SMC Networks EtherNet/IP EX500-GEN1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SMC Networks EtherNet/IP EX500-GEN1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSMC Networks EtherNet/IP EX500-GEN1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SMC Networks EtherNet/IP EX500-GEN1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSMC Networks EtherNet/IP EX500-GEN1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。