OPERA TION MANUAL SMC Corporation SI unit EX120-SDN1 Doc.No. EX## -OME0015 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1.
Contents 1.Safety instructions ------------------------------------------------------ P3 2.S pecifications 2-1.General specifications ------------------------------------------------------ P4 2-2.Electrical and network specifications ------------------------------------------------------ P4 2-3.
SMC CORPORA TION Doc.No.EX ## -OME0015 1.Safety instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by label of "CAUTION" , "WARNING".
- 4 - 2-1. General specifications Item S pecifica tions Model EX120 -SDN1 EX121 -SDN1 EX122 -SDN1 EX124D -SDN1 EX124U -SDN1 Operatin g ambient temp. 0 to +55(with 8 po ints o f valve O N) 0 to +50 ℃ (with 16 p oints o f valv e ON) Operating a m bient humidity 35 to 85%RH(No dew cond ensation) S torage ambient temp.
- 5 - 3. Wiring and Setting 2-3. Applicab le solenoid v alve series SI unit V alv e series EX120 VQ1000, VQ2000 EX121 VQ1000, VQ2000, SX 3000, SX5 000 EX122 SY3000, SY5000 EX124U/ D VQ2000, VQ4000, VQ.
- 6 - Cable specification CAUTION For Multi drop connection, prepare plug connector for T branch separately . (Example, TMSTBP 2.5...- STF -5.08 made by Phoenix Contact Corp.) Use DeviceNet special cable for communication cable. Be sure to connect DeviceNet special terminal resistor with both ends of trunk.
Wiring of cable for solenoid valve power supply and communication Communication connector for DeviceNet T erminal Wire color Connected to V - Black (-) side of power supply cable CANL Blue Low side of.
3-2. Addr ess setting Before setting of address by DIP switch, turn power supply for communicat ion cable in SI unit “OFF ”. Setting (binary) of following items is available by DIP switch installed to cover . 1) Node address (00 to 63) 2) Communication speed (125k bps, 250 kbps, 500kbps) - 8 - SMC CORPORA TION Doc.
4.LED indicator and Physical dimensions - 9 - Indication Contents P W R Green Lights up when power for DeviceNet line is supplied. Lights off SI unit isn’t on line or power supply for communication line isn’t tur ned on .
- 10 - SI unit (EX122-SDN1) SI unit (EX121-SDN1) SMC CORPORA TION Doc.No.EX ## -OME0015 1 1 1 1 0 0 2 2 3 3 4 4 5 5 6 6 7 7 8 8 0 0 1 1 2 2 4 4 8 8 16 16 32 32 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 1 1 0 0 .
SI unit (EX124D-SDN1) SI unit (EX124U-SDN1) - 1 1 - SMC CORPORA TION Doc.No.EX ## -OME0015 4-G(PF)1/2 19 19.8 11 4 5.5 67 (72.5) 53.8 1 1.6.
5.EDS (Electronic Data Sheet) File SMC CORPORA TION Doc.No.EX ## -OME0015 The EDS File is a file which described ID information on SI unit and important information in the operation. The DeviceNet controller or scanner automatically recognizes the SI unit by referring to the EDS File.
6. T rouble Shooting - 13 - MOD/NE T L ED Cause & Countermeasure Light s off PWR L ED lig hts of f <Counte rmeasure> Confir m that power for SI unit circuit is sup plied. Confirm correct wi ring. If above cou ntermeasures do not improve st atus, p lease excha nge SI unit .
デバイスSMC Networks EX120-SDN1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SMC Networks EX120-SDN1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSMC Networks EX120-SDN1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SMC Networks EX120-SDN1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SMC Networks EX120-SDN1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SMC Networks EX120-SDN1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSMC Networks EX120-SDN1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SMC Networks EX120-SDN1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSMC Networks EX120-SDN1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。