SMSC EMC1002/EMC1033 Revision 1.1 (12-14-06) The information cont ained herein is propri etary to SMSC, and sha ll be used solely in accordance with the agre ement pur- suant to which i t is pr ovided. Althoug h the inf ormatio n i s beli e ved to be accurate, no responsibility is assumed for inaccura- cies.
EVB-EMC1002/EMC1033 User Manual Revision 1.1 (12-14-06) SMSC EMC1002/EMC1033 2 1 Overview The EMC1002 is an SMBus temperature sensing IC with 1 internal an d 1 external sensor in an 8 pin MSOP package. The EMC1002 has 2 Alert /Therm2 and Addr/Therm outputs that can be configured to signal when temperatures e xceed programmed limits.
EVB-EMC1002/EMC1033 User Manual SMSC EMC1002/EMC1033 Revision 1.1 (12-14-06) 3 2 Getting S t arted 2.1 System Requirement s T o use the EVB you will nee d: n A PC running Windows 2000 or XP n Display resolution 800x60 0 (or larger to view several wi ndows simultaneously) n An available USB port 2.
EVB-EMC1002/EMC1033 User Manual Revision 1.1 (12-14-06) SMSC EMC1002/EMC1033 4 Note: The Windows R egister Manager applica tion allows view ing and changing re gister values for a variety of EVBs including the EMC1001, EMC1002, EMC 1023 and 1033. The Reg ister Manager software only needs to be installed once to support all of these EVBs.
EVB-EMC1002/EMC1033 User Manual SMSC EMC1002/EMC1033 Revision 1.1 (12-14-06) 5 3 Circuit Description 3.1 Introduction The EMC1002 EVB provides the means to demons trate EMC1002/1033 features and to view and modify registers.
EVB-EMC1002/EMC1033 User Manual Revision 1.1 (12-14-06) SMSC EMC1002/EMC1033 6 3.8 Direct SMBus Connect Option It is also possible to connect an external SMBu s master to the EMC1002 EVB. A few modifications to the circuit are required: n Cut 3 traces connecting JP4 pins 3-4, 5-6 and 7-8 o n the bottom side of the PCB.
EVB-EMC1002/EMC1033 User Manual SMSC EMC1002/EMC1033 Revision 1.1 (12-14-06) 7 4 Demo Description 4.1 Register Manager Overview The Register Manager a pplication (RegMa n) initially displays the main Hel p screen, where detailed description of th e application’s features may be f ound.
EVB-EMC1002/EMC1033 User Manual Revision 1.1 (12-14-06) SMSC EMC1002/EMC1033 8 Note: Asserting the Addr / Therm output low will also tu rn on the ARA LED on this EVB. This is because the fan driver circuit will pull down the Alert /Therm2 output when Add r / Therm is low .
デバイスSMSC EVB-EMC1002の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SMSC EVB-EMC1002をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSMSC EVB-EMC1002の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SMSC EVB-EMC1002の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SMSC EVB-EMC1002で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SMSC EVB-EMC1002を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSMSC EVB-EMC1002の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SMSC EVB-EMC1002に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSMSC EVB-EMC1002デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。