Solid State LogicメーカーLINK MADI HDの使用説明書/サービス説明書
ページ先へ移動 of 32
X X L L o o g g i i c c D D e e l l t t a a - - L L i i n n k k M M A A D D I I H H D D MADI Interface for Digidesign ® HD Systems Installation and User Guide 82S6ALS20C Solid State Logic S O U N D |.
.
Safety and Installation Considerations 1 1. Introduction 3 XLogic Delta-Link MADI HD 3 Reading conventions 4 2. Overview 5 Front panel 5 Rear panel 6 3. Installation 8 4. Synchronization 10 Pro T ools ® HD card 10 Delta-Link MADI HD 10 W ordClock / FrameClock 1 1 High Speed and SMUX modes 12 5.
.
This section contains definitions, warnings, and practical information to ensure a safe working environment. Please take time to read this section befor e installing or using this unit. Please do not dispose of these instructions. Safety and Installation Considerations General Safety • Read these instructions.
2.
3 XLogic Delta-Link MADI HD Congratulations on your purchase of the XLogic Delta-Link MADI HD! Please be assured that it will provide you with many years of reliable service while delivering the pristine audio quality you expect from any Solid State Logic product.
Reading conventions Software menus Where appropriate, to indicate a “path” under a Solid State Logic or Pro T ools ® software menu, the following format will be used; menu: Header|Submenu 1|Submenu 2|Submenu 3|Item.
5 Front panel Power switch Lock LED Power LED Power switch This switch is used to power the unit up or down. Power LED This LED is lit when the Delta-Link MADI HD is switched on. Lock LED This LED indicates that a W ordClock signal is received: • It is lit when the Delta-Link MADI HD is receiving a stable signal at the required sample rate.
Rear panel Primary Port A Primary Port B USB Port Mains connector MADI Port A output (left) MADI Port B output (left) W or dClock input and input (right) and input (right) 6.
7 Primary Port A / Primary Port B Each Pro T ools ® HD port provides 32 input and output channels, regardless of sample rate. MADI A / MADI B The two MADI ports provide up to 64 input and output channels, depending on sample rate.
The Delta-Link MADI HD package includes: • The Delta-Link MADI HD unit. • 2 of 0.9m (35") DigiLink cables. • The mains connection cable. • This manual.
9 1. In a typical setup, connect Primary Port A of the Delta-Link MADI HD to the Primary Port of your HD Core card and Pri mar y Port B of the Delt a-L ink MA DI HD to th e Prima ry Port of y our fir st HD Accel ca rd via Digi Lin k ca ble s suppl ied .
Pro T ools ® HD card The Pro T ools ® HD card is designed to operate as a Clock Slave, locking to a clock reference signal provided by the audio unit connected to its primary port. The interface unit can define the sample rate internally , or can itself be synchronized to an external reference signal (e.
1 1 W ordClock / FrameClock The W ordClock input can translate W ordClock or FrameClock to the required Sample Rate. The “LOCK” LED on the front panel indicates reception of a stable signal.
High Speed and SMUX modes • Sampli ng frequencies up to 48kHz are des ignate d as being in the “NFS rang e” (from NFs, Normal Freq uency sampling) . • Sampling frequencies above 48kHz and up to 96kHz are in the “DFS range” (from DFs, Double Frequency sampling).
13 I/O mapping and Sample Rate range NFS range (44.1kHz to 48kHz): 64-48 “normal” mode T wo Primary Ports interact with one MADI Port. Primary Port A, channel 01 ↔ MADI Port A, channel 0 Primary.
NFS range (44.1kHz to 48kHz): 64-48 “special” mode T wo Primary Ports interact with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 32 ↔ MADI Port .
15 DFS range (88.2kHz to 96kHz): 64-96 mode T wo Primary Ports interact with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 32 ↔ MADI Port A, channel .
QFS range (176.4kHz to 192kHz): 32-192 mode One Primary Port interacts with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 16 ↔ MADI Port A, channel 1.
17 General information The Delta-Link MADI HD can work with Pro T ools ® HD systems running on a W i ndows PC or Macintosh OS X computer . Using the Delta-Link MADI HD with the Pro T ools ® software is generally straightforward.
The screenshot below was made using a Pro T ools ® HD system with a single Del ta-Link MADI HD which appears as a set of 192 I/O peripherals (see below , top left).
19 Remote control of Delta-Link MADI HD settings Some Delta-Link MADI HD system settings can be controlled via the Analog Out tab of the Pro T ools ® software’ s Hardware Setup window (select Setup|Hardw are ).
In the Hardware Setup window , the “Output T rim” settings are irrelevant to the Delta-Link MADI HD because its inputs and outputs are all digital.
21 Known issues Start up errors When the Pro T ools ® software starts up, it uses the settings defined during the previous session, e.g. number and type of Audio Interfaces, I/O setup, etc.
The best way to ensure all Legacy Interfaces are removed is to click the name of a Legacy Audio Interface (e.g. 882/20 or 888/24) and to select “No Interfaces” from the “Interface” drop down box.
23 Playback Engine The Delta-Link MADI HD provides up to 64 input and output channels. Therefore, the number of voices for the Playback Engine may need to be increased. For instance, in order to playback and record 64 tracks simultaneously at 96kHz, go to menu: Setup|Pla yback Engine and select “128 voices”.
System Resources The system resource usage can always be checked in the Pro T ools ® software under menu: Windo w|System Usage : Firmware Updates The Delta-link MADI HD features a USB connector on th e bac k pane l to allo w for fire wir e upda tes or setti ngs modifications.
25 Symptoms Possible solutions The Delta-Link MADI HD is not detected by the software. Check that the Delta-Link MADI HD is connected to the mains supply and that the Power switch is in the On position (the Power LED should be lit). Check the condition of the mains cable.
26 8. Specifications Physical * Depth 175mm / 7" casing only Height 44.5mm / 1.75" (1 RU) W idth 438mm / 17.25" casing only 482mm / 19" inc’ rack ears W eight 2.2kg / 5 pounds Power < 15 W atts Boxed size 320mm x 550mm x 80mm 12.
27 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfu l interfe rence in a res identia l instal lation.
Solid State Logic S O U N D | | V I S I O N V isit SSL at URL: http://www .solidstatelogic.com © Solid State Logic All Rights reserved under International and Pan-American Copyright Conventions VHD, .
デバイスSolid State Logic LINK MADI HDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Solid State Logic LINK MADI HDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSolid State Logic LINK MADI HDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Solid State Logic LINK MADI HDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Solid State Logic LINK MADI HDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Solid State Logic LINK MADI HDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSolid State Logic LINK MADI HDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Solid State Logic LINK MADI HDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSolid State Logic LINK MADI HDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。