SonyメーカーBKP-7933の使用説明書/サービス説明書
ページ先へ移動 of 56
S-BUS INTERF ACE BOARD BKP-7933 INST ALLA TION MANUAL 1st Edition (Revised 1).
! W ARNING This manual is intended f or qualified ser vice personnel only . T o reduce the r isk of electric shock, fire or injury , do not perf or m any ser vicing other than that contained in the operating instructions unless you are qualified to do so.
1 (E) BKP-7933 Table of Contents Manual Structure Purpose of this manual ........................................................................................ 3 (E) Related manuals ...................................................................
2 (E) BKP-7933 1-9. Modification of RCP ........................................................................... 1-39 (E) 1-9-1. Checking ROM Version ..................................................... 1-39 (E) 1-9-2. Modification of RCP-700/701 .
3 (E) BKP-7933 Purpose of this manual This manual is the installation manual for S-BUS Interface Board BKP-7933. This manual describes the information items necessary when the unit is supplied and installed. Relative manuals Besides this installation manual the following manuals are available for this unit.
.
1-1 (E) BKP-7933 Section 1 Installation 1-1. Checking ROM Version When the BKP-7933 is installed in the CNU-700, be sure to check that the ROM versions for IC4 and IC5/AT-89 board of the CNU-700 are Ver. 3.00 or higher. If the ROM needs to be replaced, contact your local Sony Sales Office/Service Center.
1-2 (E) BKP-7933 1-4. Setting Switches on the IF-689 Board m . Be sure make the switches settings for the CNU GROUP No. and S-BUS ID No. before turning on the power. It is no use in setting the switches after turning on the power. . Do not change the following switches from their factory default settings.
1-3 (E) BKP-7933 18 7 6 5 4 3 2 1 () 128 64 32 16 8 4 2 S-BUS ID No. Setting example 1 3: 0 0 0 0 0 0 1 0 64: 0 1 0 0 0 0 0 1(ON) 0(OFF) Setting of S-BUS ID No. S12 (S-BUS ID No.) Set the station address for the unit on the standard S-BUS data link. n Set to numbers other than 0, 1 and 255.
1-4 (E) BKP-7933 1-5. Installation 1-5-1. Installing the IF-689 Board n The unit is equipped with shielding springs which have sharp edges. Do not touch them with bare hands. Pay careful attention when servicing. 1. Loosen the two screws and remove the front panel of the CNU-700.
1-5 (E) BKP-7933 1-5-2. Installing the Rear Panel 1. Remove the two screws and remove the blank panel. 2. Install the rear panel with the two screws instead of the blank panel.
1-6 (E) BKP-7933 1-6. Connection 1-6-1. Connection Connector/Cable Connection made with the connector panel during installation or service, should be made with the connectors/complete assemblies specified in the following list, or equivalent parts.
1-7 (E) BKP-7933 1-6-2. Connector Input/Output Signals REMOTE S-BUS BNC 75 Z , 1.0 Vp-p I/O PORT (D-sub 50P, Female) (External view) Pin No. I/O Specifications 1 IN/OUT EXTO 0 2 IN/OUT EXTO 3 3 IN/OUT.
1-8 (E) BKP-7933 1-6-3. Notes on Connection To connect the devices to the S-BUS line, refer to Section 1-6-4 and following precautions. . The cable length of one S-BUS line is a maximum of 500 m (when a BELDEN 8281 or the equivalent is used).
1-9 (E) BKP-7933 CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE TRIAX CABLE 1 CAM 2 CAM 3 CAM TRIAX CABLE TRIAX CABLE CNU CHAR.
1-10 (E) BKP-7933 1-7. Setting Up n The description in this section assumes that the BKPF-R70 is used as the primary station. 1-7-1. Outline Calling the Menu Display of the Secondary Station First, call the menu display of the secondary station that is connected to the S-BUS of the primary station.
1-11 (E) BKP-7933 12131415 1 1 12 33 33 44 44 45 45 56 56 57 57 58 68 1024 1024 ROUTER PIX1 CAMERA-CCU CCU-RCP MSU2 MSU1 SOURCE No. DESTINATION No. LEVEL-1 ROUTER PIX3 ROUTER PIX2(MSU2) ROUTER PIX2(MSU1) Saving the Setup Data Press [Ctrl] - [E] to validate and save the setup data and to return to the BKP-7933 menu display.
1-12 (E) BKP-7933 1-7-2. Linking the RCP Assignment and VE Monitor Selection Description of Operation Set the menu as follows when you want to link the RCP assignment with the VE monitor selection.
1-13 (E) BKP-7933 CCA-5 CABLE CCA-5 CABLE REMOTE RCP/CNU REMOTE CCU/CNU REMOTE CCU/CNU REMOTE CCU/CNU REMOTE CCU/CNU CCU 1 to 6 RCP 1 to 6 MSU IN 1 OUT 1 OUT 2 OUT 6 REMOTE 1 RE.
1-14 (E) BKP-7933 Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-15 (E) BKP-7933 1-7-3. Linking the MSU Camera Selection and the VE Monitor Selection Description of Operation Set the menu as follows when you want to link the MSU camera selection with the VE monitor selection.
1-16 (E) BKP-7933 * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX or WF connector (PIX 2 or WF 2 connector for the CCU-700A series) CCA-5 CABLE CCA-5 CABLE REMOT.
1-17 (E) BKP-7933 Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-18 (E) BKP-7933 * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector CCA-5 CABLE CCA-5 CABLE REMOTE RCP/CNU REMOTE CCU/CNU REMOTE CCU/CNU .
1-19 (E) BKP-7933 SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.00 STATION NUMBER 2 MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU) B: SET UNIT LOCATION(CCU-RCP) C.
1-20 (E) BKP-7933 Linking the Preview Monitor Selection with MSU and VCS 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-21 (E) BKP-7933 Changing the Operation Mode of the RCP PREVIEW Switch The operation mode of the RCP PREVIEW switch can be changed on the CNU-700 character display. Use the switches on the AT board inside the CNU-700 for this setting. 1. Set the MODE switch to 5.
1-22 (E) BKP-7933 1-7-5. Executing RCP Assignment from Equipment Other Than MSU Description of Operation Set the menu as follows when you want to execute RCP assignment from equipment other than MSU. When this setting is executed, a maximum of 96 x 96 CCU-RCP matrix can be set in the matrix space of the S-BUS.
1-23 (E) BKP-7933 * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector CCA-5 CABLE CCA-5 CABLE REMOTE RCP/CNU REMOTE CCU/CNU REMOTE CCU/CNU .
1-24 (E) BKP-7933 SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.00 STATION NUMBER 2 MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU) B: SET UNIT LOCATION(CCU-RCP) C.
1-25 (E) BKP-7933 * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector CCA-5 CABLE CCA-5 CABLE REMOTE RCP/CNU REMOTE CCU/CNU CCU 1 to 6 MSU IN .
1-26 (E) BKP-7933 Setting from the S-BUS Primary Station 1. Select the menu item “C:SET UNIT LOCATION (MSU)” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-27 (E) BKP-7933 1-7-7. Changing the Camera Assignment Virtually Description of Operation Set the menu as follows when you want to change the camera assignment virtually. When this setting is executed, the camera assignment can be changed virtually without changing the cable connection be- tween the cameras and CCUs.
1-28 (E) BKP-7933 Displaying the SOURCE NAME on the CNU Character Display 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-29 (E) BKP-7933 1-7-8. Using the Tally System Description of Operation Set the menu as follows when you want to construct a tally system using the S-BUS. When this setting is executed, the red tally and the green tally signals are accepted through the S-BUS and are output to the corresponding CCU and camera in the form of command signals.
1-30 (E) BKP-7933 Setting from the S-BUS Primary Station 1. Select the menu item “Z:BKP-7933 CONFIGURA- TION” and press [ENTER] . SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.
1-31 (E) BKP-7933 5. Return to the previous screen by pressing [Ctrl] - [E] , and select the menu item “H:BKP-7933 MODE”. BKP-7933 CONFIGURATION BKP-7933 V1.
1-32 (E) BKP-7933 1-7-9. Displaying the Self-diagnostic Information on the Terminal Description of Operation Set the menu as follows when you want to display the self-diagnostic information on the display.
1-33 (E) BKP-7933 1-7-10. Returning the Setups of the MODIFICATION COMMAND to the Factory Default Values 1. Select “K: RESET TO DEFAULT TABLE” using the cursor key and press [ENTER] . 2. The message “Reset to Default table?” appears in the bottom right of the screen.
1-34 (E) BKP-7933 * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc.), connect it to PIX, WF or VBS connector CCA-5 CABLE CCA-5 CABLE CCA-5 CABLE REMOTE RCP/CNU REMOTE CCU/CNU CC.
1-35 (E) BKP-7933 1-8. Data Backup/Restore m . The description in this section assumes that BKPF-R70 is used as the primary station. . The setup data of the unit is backed up and restored by using the BZR-10 (software for data backup) supplied with the BKPF-R70.
1-36 (E) BKP-7933 1-8-2. Data Backup (Uploading) n For the details of the menu screen and the setting procedure in terminal mode, refer to the installation manual for system setup of ROUTING SWITCHER SYSTEM. For obtaining the installation manual of ROUTING SWITCHER SYSTEM, contact your local Sony Sales Office/Service Center.
1-37 (E) BKP-7933 13. Type “1” at the Function menu. (“1. RECEIVE” is selected.) The display changes to the Execution menu screen. 14. To back up the data of the BKP-7933, type “2”. (“2. The data of secondary stations” is selected.) The data is backed up in the FD.
1-38 (E) BKP-7933 1-8-3. Data Restore (Downloading) After the BZR-10 is installed according to Section 1-8-1, perform the following procedures. 1. Insert the FD on which the data is stored in an FD drive of the personal computer. 2. Type as follows. C:> a: " A > * " Type “a” or “a1”.
1-39 (E) BKP-7933 1-9. Modification of RCP The video on the preview monitor can be selected by the PREVIEW switch of the RCP-700/701/720/721/ 730/731. (Refer to section 1-7-4 for details.) However, version check of the ROM that is installed in the board of the RCP side, and modification of the board in the RCP are required.
1-40 (E) BKP-7933 1-9. Modification of RCP SW-752 BOARD SW-752 BOARD.
1-41 (E) BKP-7933 1-9-3. Modification of RCP-720 Required Part Description Sony P/N Q'ty Jumper wire __ Modification Procedure 1. Connect the two jumper wires by soldering. (SW-754 board) Between pin-6/CN3 and D25 cathode ( 1 ) Between pin-5/CN3 and pin-2/S24 ( 2 ) 2.
1-42 (E) BKP-7933 1-9-4. Modification of RCP-721 Required Parts Description Sony P/N Q'ty Resistor, Chip Metal 82 Z 1-216-625-11 1 Jumper wire __ Modification Procedure (SW-752 Board) 1. Remove the resistors R10 and R55/SW-755 board. 2. Connect a metal resistor 82 Z to the soldering land of R10, by soldering.
1-43 (E) BKP-7933 1-9-5. Modification of RCP-730/731 Required Parts Description Sony P/N Q'ty Resistor, Chip Metal 0 Z 1-216-295-11 3 Resistor, Chip Metal 82 Z 1-216-625-11 1 Modification Procedure (SW-893 Board) 1. Remove soldering of R1, R2, R3 and R12.
1-44 (E) BKP-7933 1-10. Using the BKP-7933 in the HD System Connecting Peripheral Equipment 1-10-1. Controlling the Routing Switcher via the RS-422A Interface The routing switcher can be controlled via the RS-422A interface.
1-45 (E) BKP-7933 Modification of AT-89 Board 1. Connect a jumper wire between B7 pin/CN2 and B9 pin/CN2 of the AT-89 board of the CNU-700 by soldering. 2. Remove the six screws and remove the rear panel. Remove the harness that is connected to the connector CN12 on the MB-562 board and the connector CN15 on the CN-1001 board.
1-46 (E) BKP-7933 1-10-2. Controlling a Waveform Monitor A waveform monitor can be controlled from the MSU via the I/O PORT connector of the BKP-7933, by setting the switches on the IF-689 board of the BKP-7933.
1-47 (E) BKP-7933 1-10. Using the BKP-7933 in the HD System RECALL system 1 1 2 14 25 24 23 22 21 20 19 18 17 13 2 3 34 35 18 17 50 32 33 19 20 RECALL 1 RECALL 2 RECALL 3 RECALL 4 RECALL 5 RECALL 6 RE.
1-48 (E) BKP-7933 1-11. Description on Internal Indicators Ref.No. Indicator Name Color Status D1 + 5 V Green Lights when +5 V is normally supplied to the IF-689 board D402 S-BUS RX Green Lights when .
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual.
Printed in Japan Son y Cor poration 2000. 5 08 Communication System Solutions Netw ork Company ©1998 BKP-7933 (SY) J, E 3-201-655-02.
デバイスSony BKP-7933の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sony BKP-7933をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSony BKP-7933の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sony BKP-7933の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sony BKP-7933で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sony BKP-7933を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSony BKP-7933の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sony BKP-7933に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSony BKP-7933デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。