232SPS24595 Manual Cover Page B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 B&B Electronics Mfg. Co. Inc. P.O. Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 Internet: http://www.
232SPS24595 Manual Table of Contents i B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 Table of Contents CHAPTER 1: INTRODUCTION ................................ ....................... 1 PACKING LIST ...
232SPS24595 Manual 1 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 CHAPTER 1: INTRODUCTION The 232SPS2 is a bi -directional parallel to serial converter.
2 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 SPECIFICATIONS Size: 3.8"L x 2.4"W x 0.9"H Buffer Size: 96 bytes Data Formats: Baud Rates: 1200 to 115.2k baud Data Bits: 7 or 8 Parity: Even, Odd, and None Stop Bits: 1 NOTE: 7 data bits, no parity is not supported.
232SPS24595 Manual 3 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 CHAPTER 2: PARALLEL TO SERIAL INSTALLATION When converting data from your parallel port to a serial communication format, position #8 of the dipswitch must be "ON".
4 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 CHAPTER 3: SERIAL TO PARALLEL INSTALLATION When converting data from your serial port to a parallel communication format, position #8 of the dipswitch must be "OFF".
232SPS24595 Manual 5 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 CHAPTER 4: POWER CONNECTIONS The unit may be port-powered using DTR and RTS on the serial port. If the 232SPS2 cannot be powered using the handshake lines, it may be powered externally using +7 to +18 volts DC at 2 milliamps.
232SPS24595 Manual 7 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 CHAPTER 5: SELECTING DIPSWITCH SETTINGS The 232SPS2 is set up using an eight-position dipswitch. In order for the 232SPS2 to function properly, it must be set up to match your system's requirements.
8 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 Table 5.1 Example #1 - Parallel to Serial Mode, hardware handshaking, 9600 baud, 8 d.
232SPS24595 Manual Appendix A A-1 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 APPENDIX A: PARALLEL PORT CONNECTIONS The parallel port connections for the parallel to serial and serial to parallel mode are shown in Table A-1, and Table A-2, respectively.
Appendix A A- 2 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 Table A-2 Serial to Parallel Mode DB-25 Pin # Signal Name 232SPS2 Dire.
232SPS24595 Manual Appendix B B- 1 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 APPENDIX B: SERIAL PORT CONNECTIONS The next four sections will cover the required serial port connections on the 232SPS2.
B- 2 Appendix B 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 SERIAL TO PARALLEL MODE, SOFTWARE HANDSHAKING For proper operation the following connections must be present: 1. Transmit Data (TD) from the host (DTE) must be connected to Pin #2 on the 232SPS2 module.
232SPS24595 Manual Appendix B B- 3 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 * When using XON/XOFF control, this connection may not be required. ** Some systems may require this connection. * When using XON/XOFF control, this connection may not be required.
B- 4 Appendix B 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 PARALLEL TO SERIAL MODE, HARDWARE HANDSHAKING The serial port of the 232SPS2 module is wired as a DCE device. For proper operation the following connections must be present: 1.
232SPS24595 Manual Appendix B B- 5 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 Some printers may require one or more of the following connections: 6. Data Set Ready (DSR) from the printer must be connected to Pin #6 on the 232SPS2 module.
B- 6 Appendix B 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 TABLE B-4 DB-9 Serial Port Connections (P to S) Serial Port (DTE) DB-9.
232SPS24595 Manual Appendix C C- 1 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 APPENDIX C: SOFTWARE HINTS PARALLEL TO SERIAL MODE In parallel to serial mode, data from the computer is output through the parallel port.
C- 2 Appendix C 232SPS24595 Manual B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 MODE COM1: 96,n,8,1,p If any of the parameters are omitted, the most recent setting will be used. It is recommended that the "p" option be used for the retry option.
232SPS24595 Manual Appendix D D- 1 B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 434-7094 APPENDIX D: TROUBLESHOOTING Symptom Possible problem Solution No data is being Printer is off-line Put printer on-line printed.
FCC Class A Equipm ent Statem ent FEDERA L COM M UNICA TIONS CO MMISSI ON RA DIO FREQ UENCY INTERFA CE STA TEMENT Class A Equip ment T his equipment has been tested and found to com ply w ith the limits for Class A digital device, pursuant to Par t 15 of the FCC Rules.
デバイスB&B Electronics 232SPS2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
B&B Electronics 232SPS2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはB&B Electronics 232SPS2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。B&B Electronics 232SPS2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。B&B Electronics 232SPS2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
B&B Electronics 232SPS2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はB&B Electronics 232SPS2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、B&B Electronics 232SPS2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちB&B Electronics 232SPS2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。