http: //www.del ta.com .tw/i ndustr ialau tomation / DEL T A T emperature Controller DTB Series User Manual.
1 B Series Temperature Controller User Manual 1 Precaution DANGER! Caution! E lectric Shock! 1. Do not touch th e AC terminals w hile the power is sup plied to the controller to prevent an electric s hock. 2. Make sure pow er is disconnected while checking th e unit insi de.
2 4 Specifica tions 5 T emperature Sensor T ype and T emperature Range Input T emperature Sensor T ype Register V alue LED Display T emperat ure Range 0~50mV Analog Input 17 -999 ~ 9999 4~20mA Analog .
3 6 Operation There are three modes of operation: operation, regulation and in itial setting. When power is applied, controller gets into the operation mode. Press the key to switch to regulation mode. If the key is pressed for more than 3 seconds, c ontroller will switch to t he initial setting mode.
4 T ime setting for valve from full close to full open. (Displa y when valve cont r ol is ON) Pr ess D ispl ay and ad jus t out put va lu e of 1st o utp ut gr oup (Di s pla y in PID con tr ol mode and man ual RU N m o d e) Press ASCII, RTU com mun ication format select io n Press Pr e s s V alv e Dea d B and setti ng.
5 7 Dual Loop Output Control (Heating / Cooling Contr ol) OF F PV Set p oint ON He atin g De ad ban d He ati n g h yst eresi s Fi gure 1. O utp ut d uri ng dua l l oo p out put con t ro l oper ation o.
6 8 Alarm Output s There are up to three groups of alarm outputs and each group allows thirteen alarm types in the initial setting mode. The alarm output is activated whenever the process temperature value (PV) is getting higher or lo wer than the set point of alarm limit.
7 9 Current T ransformer (CT) Function The Current T ransformer ( CT) function is used with the alarm out put. When using a current transforme r (CT) with the controller , change the corresponding alarm output mode to mode 13 (alarm output set value is 13), then turn to operation mode and set the current lowe r-limit and current upper-limit.
8 13 RS-485 Communication 1. Supporting transmission speed: 2400, 4800, 9600, 19200, 38400bps 2. Non-supported formats: 7, N, 1 or 8, O, 2 or 8, E, 2 3. Communication protocol: Modbus (ASCII or RTU) 4. Function code: 03H to read the contents of register (Max.
9 1030H S tart pattern number 0 ~ 7 1040H~ 1047H Actual step number setting inside the correspond pattern 0 ~ 7 = N, indicate that this pattern is executed from step 0 to step N 1050H~ 1057H Cycle num.
10 14 Panel Cutout and T erminals Identification Panel Cutout ( dimensions are in millimeter and inch) T ermi nals Identification DTB4824 65 .0 m in. (2. 56) 4 0 . 0 m i n . ( 1 . 5 8 ) 44 .8 (1. 76) 2 2 . 0 ( 0 .8 7 ) +0.6 -0 +0.02 -0 + 0 . 6 - 0 + 0 .
11 15 External Dimensions Dim ensions are in millimeter (inch) DTB4824 DTB4848 48.0 mm (1.89 in) 2 4 . 0 m m ( 0 . 9 4 i n ) 3.4 mm (0.13 in) 99.8 mm (3.93 in) 2 1 . 8 5 m m ( 0 . 8 6 i n ) 44.75 mm (1.76 in) 2 2 . 0 m m ( 0 . 8 7 i n ) 44.8 mm (1.
12 16 Mounting Mounting Method Mounting Bracket Installation CT Wiring Method (if C T function is selected) S tep 1 : Insert t he controller through the panel cutout.
デバイスB&B Electronics DTB Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
B&B Electronics DTB Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはB&B Electronics DTB Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。B&B Electronics DTB Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。B&B Electronics DTB Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
B&B Electronics DTB Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はB&B Electronics DTB Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、B&B Electronics DTB Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちB&B Electronics DTB Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。