OXOR II INSTRUCTION 19-9126 Portable Oxygen Analyzer Part No. 19-7037 & 19-7044 Rev. 6 – October 1999 ® Bacharach, Inc. 621 Hunt Valley Circle, New Kensington, PA 15068 PH: 724-334-5000 • FAX: 724-334-5001 • Web: www.bacharach-inc.com E-mail: help@bacharach-inc.
WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.
1 WARNING! Because this instrument is used to detect and monitor materials and conditions which are listed by OSHA or others as potentially hazardous to personnel and property, the information in this.
2 Figure 2. Battery Installation To prepare the instrument for operation, you must install four “C” size batteries, and (if desired) install the hose and probe as described in the following paragraphs.
If batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuitry. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool.
4 4 OPERATION To operate the Oxor II, you simply . . . • Set its POWER switch to ON, • Wait for the instrument to warm up (approx. 1 minute), • Span the display (if necessary), • Take a gas sample. Detailed operating procedures are presented below: 4.
5 4.6 Interpreting the Display Gas Display The LCD directly shows O 2 levels in the range from 0 to 25%. The display on the right indicates a O 2 level of 20.9%. 4.4 Using the Strap The instrument's elastic strap allows the unit to be either hand-held, or hung on nearby objects.
6 Low Battery Indications When the battery voltage becomes low, the “LO BAT” indicator appears. Although the instrument will continue to operate and give percent O 2 read- ings under these conditions, the batteries should be replaced as soon as possible.
6 PARTS/SERVICE 6.1 Parts List Item Part No. Battery Cover 19-3029 Basic Probe/Hose Assy. 19-3086 Optional Probe/hose Assy. 19-3076 6.2 Bacharach Sales/Service Centers 7 United States Bacharach, Inc. 621 Hunt Valley Circle New Kensington, PA 15068 Phone: 724-334-5051 Fax: 724-334-5723 E-mail: help@bacharach-inc.
Notes: 8.
デバイスBacharach 19-7044の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bacharach 19-7044をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBacharach 19-7044の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bacharach 19-7044の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bacharach 19-7044で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bacharach 19-7044を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBacharach 19-7044の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bacharach 19-7044に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBacharach 19-7044デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。