SonyメーカーSRP-X500Pの使用説明書/サービス説明書
ページ先へ移動 of 37
SRP-X500P © 2004 Sony Corporation 2-190-706- 13 (1) Digital Powered Mixer Operating I nstructions Before op erating the unit, pleas e read thi s manual thoroughl y and retain it for futur e referen ce.
2 • Read these instructions. • Keep these instruct ions. • Heed all warnings. • Follow all in structions. • Do not u se this ap paratus ne ar water. • Clean o nly with d ry cloth. • Do not block any v entilat ion openi ngs. Insta ll in accordance with the manufacturer’s instruct ions.
3 residentia l installati on. This eq uipment gen erates, uses, and can radi ate radio freque ncy energy and, i f not installe d and used in accord ance with the i nstructions, may cause harmful i nterfer ence to ra dio communic ations. However , there is no guaran tee that interference wi ll not occur in a particu lar instal lation.
4 Table of Content s Overvie w .................. ......... .............. ......... .......... .............. ....... 6 Features .................................................................................. .... 6 The SRP-X500P manuals..........
5 Connector specifications ........................................................ .. 32 Troubleshooting ..... .............. ......... ..............
6 Overvi ew Overvi ew Features The SRP-X500P is a versatile powered mi xer which incorporates an au dio mixer, RGB/video switcher, processor, and power a mplifier into a 3U-rack-size u nit. 9 preset A V system type set tings By sett ing t he SYSTEM T YPE sele ctor, the SR P-X500P supports var ious AV system comfigu rations.
7 Operati ng Conditio ns SRP- X500P M ana ger This is a program fo r setting t he SRP-X500P parameters from a PC. The Engl ish and the Simplified Chinese version s are provided. How to open files 1 Inser t th e suppli ed CD -ROM in to the CD-R OM dri ve, then cli ck “My Computer .
8 Precaut ions Precauti ons • The SRP- X500P must be use d within a temper ature range of 0 ° C to 4 0 ° C (32°F to 104°F). • Operati ng the SR P-X500P nea r ele ctrical equ ipment (motors, tr ansformers, or dimmers) may cause it to be affected by elect romagnetic in duction.
9 Location and Function of Parts Location and Fu nction of Part s Fr ont panel A POWER switc h Turns the SRP -X500P on an d off. With the SRP -X500P Mana ger software, yo u can set a parameter that will cause the projector or displa y monitor connected to th e SRP-X500P t o turn o n or ente r standby status when the POWER swit ch is pressed.
10 Locat ion and Func tion of Pa rts MIC 3: Ad justs the level of t he signa l inpu t from th e MIC INPUT 3 co nnector. MIC 4: Ad justs the level of t he signa l inpu t from th e MIC INPUT 4 co nnector. LINE: Adjusts the leve l of th e signals input from the LINE IN connectors.
11 Location and Function of Parts Note For c ontr ol of an LCD Da ta Pr oject or V PL-PX 15, us e the CONTROL S conn ectors in stead of t he PROJECTOR CONTROL RS- 232C conne ctor. N SYST EM TY PE s elec tor Can be set to posit ions 1-9, according to the speaker configuration of t he AV system being used .
12 Locat ion and Func tion of Pa rts Rear panel A ANT IN a/b connectors (BNC type) Connect antennas f or the tuner unit inst alled i n the SRP- X500P. Only the supplied an tennas o r the UHF Ant enna AN-820 (not supplied) ca n be used.
13 Location and Function of Parts Input pins Output pins E REMOTE RS-232C conn ector (D-s ub, 9-pin, male ) This is an RS-232C serial connector for remote control. When a PC is c onnecte d, para meters can be set usin g the SRP-X50 0P Manage r sof tware.
14 Install ation Installati on Installi ng the tuner units Up to two WRU-80 6 UHF Synthesi zer Tuner Unit s (not supplie d) or two UR X-M1 Tune r Units inc luded in th e UWP-X1/X2 (not supplied) can be inst alled in t he SRP- X500P.
15 Instal lation Note When removin g the b lank panel s to th e SRP-X500P, b e sure to start with th e small panel. Rac k mountin g About th e rack Use an EIA-standa rd 19-inc h rack with a depth of 450 mm or more.
16 Install ation Releasing the but tons automati cally cancels the group and channel selection mode, and the currently displayed group is selected . Refer to “Wi reless Microphone Sy stem Freque ncy List” supp lied wit h the WRU-806. 3 Press and hold do wn the CH button , and press the + or – button in 3 seco nds to select a c hannel.
17 System Config urations and Spe aker Connec tions System Conf igurations a nd Speake r Connections Sample configuration using the SRP-X500P factory-settings In this con figur ation, t he SRP-X500P c an be used wit hout havi ng to change the setting s with the su pplied SR P-X500P Manager software.
18 System Conf igurations and Speaker Conne ctions Sample system conf iguration with a custom operation panel and en vir onmental equipment connected In this conf iguration, the S RP-X500P can be cont rolled by a cust om operation pan el or an ext ernal system controll er.
19 System Config urations and Spe aker Connec tions Speaker connection Only speakers with lo w impedance (4 to 16 Ω ) can be connected to the SPEAKERS CH-1/2 terminals. Speakers of high or low impedance can be conn ected to the SPEAKER S CH-3/4 term inals by set ting the SYS TEM TYPE sel ector .
20 System Conf igurations and Speaker Conne ctions Audio from the AV compon ents is out put from the f ront speakers i n stereo, and au dio from the mi crophones is output fro m the ceiling speak ers to enhance c larity. • Input/ outp ut •D e l a y Distance compensat ion is not set.
21 System Config urations and Spe aker Connec tions SYSTEM TY PE 4 For a speak er system consi sting of hi gh-impedance ceiling speakers (70V L INE). Audio from the AV compon ents (monau ral) and the microphones i s outpu t from th e ceiling speakers.
22 System Conf igurations and Speaker Conne ctions •D e l a y SYSTEM TYPE 6: Select when no co mpensation is necessary. SYST EM TYPE 7 : Select when the distance betw een the front speakers and th e satellite speakers a re 5 meters to 8 meters (16.7 feet to 26.
23 Controls BACK REDUCER button to cancel the procedure, turn down t he SPEAKER OUT control, then t ry aga in. • Do not make a noise whil e the SRP-X500P is scanning the fr equency bands, as this may cause er ror in dete ctio n.
24 Controls to “0” and use the SRP- X500P Manager software to make se ttings . • For con trol of an LC D Data Project or VPL-PX15 , use the CONTROL S connectors instead o f the PROJECTOR CONTROL R S-232C conn ector. For details, see “PROJECT OR CONTROL C ONTROL S IN/OUT connectors” (pa ge 24).
25 Controls Speci fic ation s Connecto r type: D- sub 25-pin, f emale Recommended cabl e: Multi-core shielded cable for data communication s Cable lengt h: 50 met ers (166 fe et) or le ss Exampl es of.
26 Controls START bu tton Press to turn on the project or or monitor, lo wer the screen, close the curtains, and di m the lights as preparation for the start of a presenta tion.
27 Controls Preca ution s on the use o f inte rface boxes fo r envir onment al eq uipmen t (sc reen, curtain s, li ght) • The output pins of the REMOTE PARALLEL con nector provide open-col lector outpu t for alternate o peration.
28 Controls lightin g equi pment turns o n when an EMG tally si gnal is output from pin 24 (OUTPUT 10). Pr ogramming a r emote commander Commands th at contr ol the SRP- X500P fun ctions can be stored to a n optiona l progr ammable remote c ommander (RM-AV3000 series, etc .
29 Appendix Appendix Bloc k diagram ANT IN SPEAKER OUTPUT 1 SPEAKER OUTPUT 2 SPEAKER OUTPUT 3 SPEAKER OUTPUT 4 LINE OUTPUT 1 LINE OUTPUT 2 LINE OUTPUT 3 LINE OUTPUT 4 +48V RF TRIM SIGNAL VU METER MUTI.
30 Specific ations Specificat ions System A udio Frequenc y response 20 Hz to 20 kHz ±0.5 dB (with L INE OUTPUT, 1 kHz reference) T.H.D 0.01 % or less ( with LINE OUT PUT, 1 kHz) S/N ratio 94 dB or more (LINE OUTPUT, IH F-A) Crosstalk –80 dB or le ss (between LINE cha nnels, 1 kHz with input cut-off) 0 dBu = 0.
31 Specifications Signal format RGB/component Level Video signal: 0.7 Vp-p Sync sig nal: 1 t o 5 V Impedance V ideo sig nal: 75 Ω Sync sig nal: 47 k Ω OUTPUT VI DEO Connector shape Phono jack Sign.
32 Specific ations Dimensions Connector specifications PROJECTOR CONTROL RS-232C conn ector/RE MOTE RS-232C conne ctor 430 482 350 30 7 132 3 22 Unit: mm 1 5 6 9 Pin No Signal Function 1 FG F rame gr .
33 Specifications REMOTE PARALLEL connecto r AV/RGB INPUT COM PONENT/RGB connector OUTPUT COMPONEN T/RGB connector Pin No. Func tion 1G N D 2 INPUT 1 3 INPUT 2 4 INPUT 3 5 INPUT 4 6 INPUT 5 7 INPUT 6 .
34 Specific ations MIC INPUT 1 to 4 c onnectors Pin No. Fun ction 1G N D 2H O T 3C O L D.
35 Troubles hooting Troubleshoot ing Before ta king you r unit i n for re pairs, chec k the operat ion one more ti me. Should t he problem per sists, consult your nearest dealer. Launch t he supplied SRP-X500P Man ager softwar e and confirm t he setti ngs of the SR P-X500P.
NO TICE FOR USERS © 2004 Son y Corporati on. All r ights reserved . This manual or t he software desc ribed herein, in whol e or in part, may not be reprodu ced, translat ed or reduced to any machine readable from without prio r written approval from Sony C orporati on.
Sony Co r porat ion.
デバイスSony SRP-X500Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sony SRP-X500Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSony SRP-X500Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sony SRP-X500Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sony SRP-X500Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sony SRP-X500Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSony SRP-X500Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sony SRP-X500Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSony SRP-X500Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。