SouthbendメーカーP16-FR45の使用説明書/サービス説明書
ページ先へ移動 of 40
M ANUAL 1182110 REV 1 $18.00 SECTIONAL DEEP FRYER MANUAL SECTION SR OPERATOR’S MANUAL Model P16-FR45 and P20-FR65 Sectional Deep Fryer Model P16-FR45 Model P20-FR65 ! WARNING Improper installation, adjustment, alteration, se rvice or maintenan ce can cause property damage, injury or death.
S ECTIONAL D E EP F RYER P AGE 2 O PERATOR ’ S M ANUAL 1182110 REV 1 SAFETY PRECAUTIONS Before installing and ope rating this equipment, b e sure everyone i nvolved in its operation i s fully trained and aware of precautions. Accidents and problems can be ca used b y failure to follow fundam ental rules and precautions.
S ECTIONAL D EEP F RYER T ABLE OF C ONTENTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 3 Congratulations! You have purcha sed one of the finest pieces of heavy-duty co mmercial cooking equipme nt on the market.
S PECIFICATIONS S ECTIONAL D EEP F RYER P AGE 4 O PERATOR ’ S M ANUAL 1182110 REV 1 SPECIFICATIONS S PECIFICATIONS DIMENSIONS OF MODEL P16-FR45 Side View H I K J To p View B L A C Front View E F G D Width Depth Height Front Gas Connection Rear Gas Conn.
S ECTIONAL D EEP F RYER S PECIFICATIONS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 5 SPECIFICATIONS DIMENSIONS OF MODEL P20-FR65 Side View H I K J To p View B L A C Front View E F G D Width Depth Height Front Gas Connection Rear Gas Conn. Depth Option A B C D E F G H I J K L Crated Weight 36" 20.
S PECIFICATIONS S ECTIONAL D EEP F RYER P AGE 6 O PERATOR ’ S M ANUAL 1182110 REV 1 SPECIFICATIONS GAS SUPPLY AND BURNER INFORMATION Supply pressure should be greater tha n 7" W.C. for natural gas or greate r than 11" W.C. for propane. The fryer has an internal, field-convertible gas-pressure r egulator.
S ECTIONAL D EEP F RYER I NSTALLATION O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 7 INSTALLATION I NSTALLATION NOTICE Installation must conform with local codes, or in th e absence of l ocal codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installat ion Code, CAN/CGA-B149.
I NSTALLATION S ECTIONAL D EEP F RYER P AGE 8 O PERATOR ’ S M ANUAL 1182110 REV 1 INSTALLATION Step 2: Install Flue Riser The flue riser assembly is packed se parately in the shipping crate. Attach the flue riser to the top rea r of the fryer as shown in the illustration below.
S ECTIONAL D EEP F RYER I NSTALLATION O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 9 INSTALLATION Step 3: Install the Legs (or Casters) and Restraint A set of legs or ca sters is packed with t he fryer. A th readed pad is fastened to the b ase frame at each corner (see illustration on pa ge 8).
I NSTALLATION S ECTIONAL D EEP F RYER P AGE 10 O PERATOR ’ S M ANUAL 1182110 REV 1 INSTALLATION Step 4: Assembly of Frye r as Part of a Battery If the fryer is to be assembled with other units as part of a battery, do the followin g: 1. Position the center ran ge of the battery and carefully level that unit.
S ECTIONAL D EEP F RYER I NSTALLATION O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 11 INSTALLATION ! CAUTION ALL PIPE JOINTS AND CONNECTIONS MUST B E TESTED TH OROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON A LL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
I NSTALLATION S ECTIONAL D EEP F RYER P AGE 12 O PERATOR ’ S M ANUAL 1182110 REV 1 INSTALLATION Step 6: Check Clearances and Ventilation Select a firm, level location for your Southbend fryer. Leave cle arance, whenev er possible, so that access from the rear is possi ble to permit clea ning.
S ECTIONAL D EEP F RYER I NSTALLATION O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 13 INSTALLATION Step 7: Check Installation ! CAUTION IF YOU SMELL GAS DURING THE LIGHTING PROCEDURE, IMMEDIATELY SHUT OFF THE GAS SUPPLY UNTIL THE LEAK HAS BEEN CORRECTED.
O PERATION S ECTIONAL D EEP F RYER P AGE 14 O PERATOR ’ S M ANUAL 1182110 REV 1 OPERATION O PERATION NOTICE These procedures must be followed by qualif ied perso nnel or warranty will be voided. The Southbend Sectional Deep F ryer is an immersion t ube fryer.
S ECTIONAL D EEP F RYER O PERATION O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 15 OPERATION 3. While pressing the knob down, use a lit match to ignite the pilot. Contin ue to press the knob do wn for about 30 seconds. If th e pilot does not stay ignite d when the knob i s released, repeat t he lighting procedure and keep the knob do wn longer.
O PERATION S ECTIONAL D EEP F RYER P AGE 16 O PERATOR ’ S M ANUAL 1182110 REV 1 OPERATION AUTOMATIC PILOT VALVE The Automatic Pilot Valve provides an autom atic safe ty shutoff for the fryer when the pilot flame is extinguished.
S ECTIONAL D EEP F RYER C OOKING H INTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 17 COOKING HINTS C OOKING H INTS USER TIPS • Smoking oil means that the temperature is too high, or that the oil has broken down.
C OOKING H INTS S ECTIONAL D EEP F RYER P AGE 18 O PERATOR ’ S M ANUAL 1182110 REV 1 COOKING HINTS FRYING DON’TS • Don’t turn on the fryer with no shortening in the frypot.
S ECTIONAL D EEP F RYER C LEANING O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 19 CLEANING C LEANING Southbend equipment is con structed with the best quality materials and i s designed to provide durable service when prop erly maintained. To expect the be st performance, your equipment mu st be maintained in good condition and clean ed daily.
C LEANING S ECTIONAL D EEP F RYER P AGE 20 O PERATOR ’ S M ANUAL 1182110 REV 1 CLEANING 5. Close drain valve and strain the oil back into th e frypot through several thicknesses of cheesecloth, or filter it back using a filter machine. 6. Replace the basket support frame.
S ECTIONAL D EEP F RYER C LEANING O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 21 CLEANING Darkened areas, called “h eat tint,” sometimes appea r on stainless steel surfaces where the area has bee n subjected to excessive heat. These darkened areas are ca used by thickening of the protective surface of the stainless steel and are not harmful.
S ERVICE S ECTIONAL D EEP F RYER P AGE 22 O PERATOR ’ S M ANUAL 1182110 REV 1 SERVICE S ERVICE NOTICE Warranty will be void and the manufac turer is relieved of all liability if: (A) Service work is performed by other than a qualified tech nician, OR (B) Other than genuine S outhbend replacement parts ar e installed.
S ECTIONAL D EEP F RYER S ERVICE O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 23 SERVICE CHECKING AND ADJUSTING PRESSURE REGULATOR The combination gas valve and pressure reg ulator is factory set at 4" W.C. for natural gas and 10" W. C. for propane gas.
S ERVICE S ECTIONAL D EEP F RYER P AGE 24 O PERATOR ’ S M ANUAL 1182110 REV 1 SERVICE CHECKING AND ADJUSTING AUTO SAFETY PILOT The pilot flame should surroun d the thermopile for 1/ 2". It must be large an d sharp enough to cause the thermopile to glow a dull red, or sufficien t to hold the safety valve open.
S ECTIONAL D EEP F RYER S ERVICE O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 25 SERVICE TROUBLESHOOTING Problem Likely Cause Burners do not come on Gas supply to unit off. Combination gas valve is in “OFF” or “PILOT” posi tion. Pilot not ignited.
S ERVICE S ECTIONAL D EEP F RYER P AGE 26 O PERATOR ’ S M ANUAL 1182110 REV 1 SERVICE Wiring Diagram GAS INLET Notes: 1. H igh limit sw itch is set to 450 ° F. 2. Voltag e measured across TH/PP an d TP wi th main burn er on sh ould be grea ter than 100 mV.
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 27 PARTS P ARTS NOTICE INSTALLATION OF OTHE R THAN GENUINE SOUTHBE ND PARTS WILL VOID THE WARRANTY ON THIS EQUIPMENT. The serial plate is locate d inside the front door on the left side.
P ARTS S ECTIONAL D EEP F RYER P AGE 28 O PERATOR ’ S M ANUAL 1182110 REV 1 PARTS Frypot Parts for Model P16-FR45 1 2 3 Key Part Number Qty Description 1 1182221 1 F r y p o t w e l d a s s e m b l .
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 29 PARTS Frypot Parts Model P20-FR65 1 2 3 Key Part Number Qty Description 1 1182005 1 F r y p o t w e l d a s s e m b l y 2 .
P ARTS S ECTIONAL D EEP F RYER P AGE 30 O PERATOR ’ S M ANUAL 1182110 REV 1 PARTS Cabinet Parts for Model P16-FR45 See drawing on following page. Key Part Number Qty Description 1 1172716 1 N a m e .
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 31 PARTS 1 2 3 4 5 7 8 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 11 6 Cabinet Parts for Model P16-FR45 See parts list on previous page .
P ARTS S ECTIONAL D EEP F RYER P AGE 32 O PERATOR ’ S M ANUAL 1182110 REV 1 PARTS Cabinet Parts for Model P20-FR65 See drawing on following page. Key Part Number Qty Description 1 1172716 1 N a m e .
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 33 PARTS 1 2 3 4 5 6 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 11 8 7 Cabinet Parts for Model P20-FR65 See parts list on previous page .
P ARTS S ECTIONAL D EEP F RYER P AGE 34 O PERATOR ’ S M ANUAL 1182110 REV 1 PARTS Gas Train Parts for Model P16-FR45 See drawing on following page. Key Part Number Qty Description 1 1165400 1 R e a .
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 35 PARTS 1 2 13 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 3 12 Gas Train Parts for Model P16-FR45 See parts list on previous page .
P ARTS S ECTIONAL D EEP F RYER P AGE 36 O PERATOR ’ S M ANUAL 1182110 REV 1 PARTS Gas Train Parts for Model P20-FR65 See drawing on following page. Key Part Number Qty Description 1 1183744 1 S u p .
S ECTIONAL D EEP F RYER P ARTS O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 37 PARTS 1 2 17 4 5 6 7 8 9 10 11 13 15 16 18 19 20 21 22 23 24 14 25 26 27 28 29 30 31 32 3 12 14 Gas Train Parts for Model P20-FR65 See parts list on previous page .
S ECTIONAL D E EP F RYER P AGE 38 O PERATOR ’ S M ANUAL 1182110 REV 1 Notes:.
S ECTIONAL D EEP F RYER O PERATOR ’ S M ANUAL 1182110 REV 1 P AGE 39 Notes:.
S ECTIONAL D E EP F RYER P AGE 40 O PERATOR ’ S M ANUAL 1182110 REV 1 Model P16-FR45 and P20-FR65 SECTIONAL DEEP FRYER A product with the Southbend nam e incorporates the best in durability and low maintenance.
デバイスSouthbend P16-FR45の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Southbend P16-FR45をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSouthbend P16-FR45の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Southbend P16-FR45の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Southbend P16-FR45で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Southbend P16-FR45を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSouthbend P16-FR45の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Southbend P16-FR45に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSouthbend P16-FR45デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。