BaldorメーカーMN754の使用説明書/サービス説明書
ページ先へ移動 of 26
High Resolution Analog Input / Output Expansion Board Catalog No. EXBHH005A01 2/06 MN754 Installation and Operating Manual.
Any trademarks used in this manual are the property of their respective owners..
T able of Contents T able of Contents i Section 1 General Information 1‐1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 1‐1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limited W arranty 1‐2 .
ii T able of Contents.
Section 1 General Information General Information 1‐1 Introduction The Baldor controls represent the latest technology in microprocessor based motor controls.
1‐2 General Information Limited W arranty For a period of two (2) years from the date of original purchase, BALDOR will repair or replace without charge controls and accessories which our examination proves to be defective in material or workmanship.
General Information 1‐3 Safety Notice This equipment contains voltages that may be as great as 1000 volts! Electrical shock can cause serious or fatal injury . Only qualified personnel should attempt the start‐up procedure or troubleshoot this equipment.
1‐4 General Information W ARNING: Improper operation of control may cause violent motion of the motor shaft and driven equipment. Be certain that unexpected motor shaft movement will not cause injury to personnel or damage to equipment. Peak torque of several times the rated motor torque can occur during control failure.
Section 2 Expansion Board Description Description 2‐1 Introduction High Resolution Analog Expansion Board Catalog No. EXBHH005AXX. When this board is installed, two high resolution analog inputs are provided in addition to the two standard analog outputs.
2‐2 Description T able 2‐1 Characteristics High Resolution Inputs Number of Inputs Tw o Input Signal Levels +5VDC, +10VDC, 0-20 mA or 4-20mA Maximum Digital Resolution 16 bits High Resolution Outp.
Section 3 Installation Installation 3‐1 Caution: Before you proceed, be sure to read and become familiar with the safety precautions at the beginning of this manual. If you have any questions, seek expert advise before you proceed. Do not proceed if you are unsure of the safety precautions or any procedure.
3‐2 Installation 3. Be sure drive operation is terminated and secured. 4. Remove all power sources from the control. 5. W ait at least 5 minutes for internal capacitors to discharge. 6. Refer to the control manual and remove the enclosure cover . 7.
Installation 3‐3 Jumper Definitions The settings for jumpers J2 to J5 are shown in Figure 3‐2. Figure 3‐2 Jumper and T erminal Locations (T op V iew) 1 Chassis Ground 2 Analog Input 1 (+) 3 Anal.
3‐4 Installation Figure 3‐3 High Resolution Input Connections Analog to Digital Converter EXBHH005AXX Control Board Micro Processor Analog Input1 Analog Input2 2 3 1 5 4 - + - + T erminal tightening torque is 2 lb‐in (0.
Section 4 Software Setup Setup 4‐1 Overview Programming setup is accomplished using the keypad of the control. General programming steps are defined in the appropriate control manual. T o install the expansion board see Section 3 of this manual. 1. Install EXBHH005 expansion board.
4‐2 Setup Hi RES Parameters Level 1, Input Setup Block Parameter P# Adjustable Range Factory User Setting COMMAND SOURCE 1402 3-KEYP AD 4-NETWORK 5- Opt1 Ana In1 6- Opt1 Ana In2 7- Opt2 Ana In1 8- O.
Setup 4‐3 Hi RES Parameters Continued Level 1, Input Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP2 ANA IN1 TYPE 1463 0-None, 1-(-10V to+10V), 2-(-5V to+5V), 3-(4to20mA), 4-(0to20mA) 1 OP2 ANA IN1 Invert 1464 0-OFF , 1-ON 0 OP2 ANA IN1 Gain 1465 0.
4‐4 Setup Hi RES Parameters Continued Level 1, Output Setup Block Parameter P# Adjustable Range Factory User Set‐ ting ANA OUT1 Signal 151 1 18-CONTROL TEMP 19-ANALOG INPUT1 20-ANALOG INPUT2 21- O.
Setup 4‐5 Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP1 ANAOUT1 Signal 1552 0-SPEED REF 1-SPEED DEMAND 2-ACC/DEC 3-MOT OR C.
4‐6 Setup Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Set‐ ting OP2 ANAOUT1 T ype 1557 0-(0V to+10V), 1-(0V to+5V), 2-(-10V to+10V), 3-(-5V to+5V), 4-(4to20mA), 5-(0to20mA) 2 OP2 ANAOUT2 T ype 1560 2 OP2 ANAOUT1 Gain 1559 0 ‐ 200.
Setup 4‐7 Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP2 ANAOUT1 Signal 1558 0-SPEED REF 1-SPEED DEMAND 2-ACC/DEC 3-MOT OR C.
4‐8 Setup Hi RES Parameters Continued Level 2, Miscellaneous Block Parameter P# Adjustable Range Factory User Setting Filter Source 2310 4-Analog IN2, 5-Opt1 ANA1, 6-Opt1 ANA2, 7-Opt2 ANA1, 8-Opt2 A.
Section 5 T roubleshooting T roubleshooting 5‐1 Overview The Main Menu “Diagnostic” option is used to view the diagnostic screen. Diagnostic Screen At the keypad, from the Main menu the Diagnostic screens are accessed and the Option Boards display shows what boards are installed and recognized by the software.
5‐2 T roubleshooting.
Baldor District Offices.
E 2005 Baldor Electric Printed in USA 2/06 MN754 BALDOR ELECTRIC COMP ANY World Headquarters P .O. Box 2400 Fort Smith, AR 72901-2400 (479) 646-471 1 Fax (479) 648-5792 www .
デバイスBaldor MN754の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Baldor MN754をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBaldor MN754の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Baldor MN754の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Baldor MN754で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Baldor MN754を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBaldor MN754の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Baldor MN754に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBaldor MN754デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。