© 2014 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 52724 2/2015 V er . 6 USER MANUAL Safety , Operation and Maintenance SM50 HYDRAULIC SUMP PUMP.
2 ► SM50 User Manual DECLARA TION OF CONFORMITY DECLARATION OF CONF ORM ITY ÜBEREINSTIMM UNGS - ERKLARUNG DECLARATION DE CONF ORMITE CEE DECLARACION DE CONFO RMIDAD DICHIARAZIONE DI CONFO RMITA Hyd.
SM50 User Manual ◄ 3 DECLARA TION OF CONFORMITY .......................................................................................................................... 2 SAFETY SYMBOLS .............................................................
4 ► SM50 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
SM50 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose. These safety precautions are given for your safety . Re- view them carefully before operating the tool and before performing general maintenance or repairs.
6 ► SM50 User Manual 52728 SM50 Combined Decal C AU TI O N SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
SM50 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► SM50 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
SM50 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max.
10 ► SM50 User Manual PREOPERA TION PROCEDURES CHECK POWER SOURCE 1. Using a calibrated ow meter and pres sure gauge, make sure the hydraulic power source develops a ow of 7–12 gpm/26–45 Ipm at 1000–2000 psi/70– 140 bar . 2. Make certain that the power source is equipped with a relief valve set to open at 2100 psi/145 bar maxi- mum.
SM50 User Manual ◄ 1 1 CLEANING THE PUMPING CHAMBER Debris such as weeds, sand and other solids may be- come trapped in the water hose and pumping chamber . This can reduce pump performance. It is important that the pumping chamber be kept clean at all times.
12 ► SM50 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the “OFF” position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couples and cause overheating of the hy- draulic system.
SM50 User Manual ◄ 13 If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem. When diagnosing faults in operation, always make sure the hydraulic power source is supplying the correct hydrau- lic ow and pressure as listed in the table.
14 ► SM50 User Manual Capacity......................................................................................................................................... 500 gpm/1890 lpm Weight .........................................................
SM50 User Manual ◄ 15 65132 MOTOR ASSEM- BL Y USED ON SUMP PUMPS WITH SERIAL NUMBERS 600 AND ABOVE, THIS MOTOR CAN ONL Y BE PUR- CHASED AS AN ASSEM- BL Y .
16 ► SM50 User Manual ITEM NO. P ART NO. QTY DESCRIPTION 1 52669 1 VOLUTE 2 52720 1 CAMLOCK COUPLING 3 IN. 3 13815 1 HSHCS 5/16 – 18 × 3/4 4 56763 1 WASHER 5 00635 1 KEY 6 52671 1 IMPELLER 7 31032 1* SHIM .020 (* NOTE QTY WHEN DISASSEMBLING TOOL) 8 31033 1* SHIM .
SM50 User Manual ◄ 17 For underwater hydraulic tools the applications are broken down into four quadrants depending on type of tool and method of operation. The types of tools are percussive and rotational, each with different characteristics allowing for dif- ferent depth operation.
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
デバイスStanley Black & Decker SM50の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Stanley Black & Decker SM50をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはStanley Black & Decker SM50の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Stanley Black & Decker SM50の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Stanley Black & Decker SM50で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Stanley Black & Decker SM50を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はStanley Black & Decker SM50の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Stanley Black & Decker SM50に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちStanley Black & Decker SM50デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。