State Water HeatersメーカーGS675HRVITの使用説明書/サービス説明書
ページ先へ移動 of 36
1 Thank you for buying this energy efficient water heater . We appreciate your condence in our products. Y ou should thoroughly read this manual before installation and/ or operation of this water heater . Please pay particular attention to the important safety and operating instructions as well as the W ARNINGS and CAUTIONS.
2 SAFE INST ALLA TION, USE AND SER VICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
3 GENERAL SAFETY.
4 GENERAL SAFETY.
5 Thank Y ou for purchasing this water heater . Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - American.
6 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part .
7 (A) VENT PIPE (B) ANODE (C) HOT W A TER OUTLET (D) OUTLET (120 V AC) (E) FLUE BAFFLE (F) GAS SUPPL Y (G) MAIN MANUAL GAS SHUT OFF V AL VE (H) GROUND JOINT UNION (J ) SEDIMENT TRAP (DRIP LEG) (K) OUTER DOOR (L) UNION (M) INLET W A TER SHUT OFF V AL VE (N) COLD W A TER INLET FIGURE 1.
8 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certied as complying with American National Standard for water heaters and is considered suitable for: W ater (Potable) Heating and Space Heating: All models are considered suitable for water (potable) heating and space heating.
9 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
10 Minimum clearances between the water heater and combustible con stru ctio n are 0 i nc h at the sides a nd rear , 5. 5” (14.0 cm) from the fron t and 12” (30.5 cm) from the top (standard clearance). If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater .
11 located in the above manner , should be provided. Each opening should have a free area of not less than one square inch per 4000 Btu/hr (5.5 cm 2 /kW) of total input of all appliances in the enclosure.
12 CLOSED W A TER SYSTEMS W ater supply systems may , because of code requirements or such conditions as high line pressure, among others, have installed devices such as pressure reducing valves, check valves, and back ow preventers. Devices such as these cause the water system to be a closed system.
13 Figure 10 shows typical attachment of water piping to water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the water heater connections.
14 GAS PIPING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P.). The minimum inlet gas pressure shown on the rating plate is that which will permit ring at rated input.
15 SEDIMENT TRAPS (DRIP LEGS) A sediment trap (drip leg) should be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap should be either a tee tting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap.
16 2. A venting system should terminate at least 3 feet above any forced air inlet located within 10 feet. 3. The venting system should terminate at least 4 feet below , 4 feet horizontally from or , 1 foot above any door , window or gravity air inlet into any building.
17 NOTE: This unit can be vented using only the following materials: PVC (Cellular Core; ASTM-F891), PVC (DWV; ASTM D2665 or CSA B181.2), PVC (Sch 40, 80, 120; ASTM D1785 or CSA B137.3), PVC (SDR Series; ASTM-D2241 or CSA B137.3), CPVC (CPVC 41; ASTM-D2846 or CSA B137.
18 4. Do not plug in power cord until vent system is completely installed. The Power V ent operates on 120 V ac, therefore a grounded outlet must be within reach of the 6 foot exible power cord supplied with the vent. The power cord supplied may be used on unit only where local codes permit.
19 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SERVICING.
20 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT SYSTEM, the t.
21 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specic application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use.
22 B. Deburring Use a knife, plastic pipe deburring tool, or le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° should be added to the end to permit easier insertion of the pipe into the end of the tting.
23 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner .
24 The water temperature setting was factory set at the lowest temperature; Pressing the “COOLER” button decreases temperature and pressing the “HOTTER” button increases the temperature. Setting the water heater temperature at 120°F (49°C) (Approx.
25 FOR YOUR INFORMA TION ST ART UP CONDITIONS SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while. THERMAL EXP ANSION As water is heated, it expands (thermal expansion).
26 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1 . Obstructions which could cause improper venting. The combustion and ventilation air ow must not be obstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion products.
27 INST ALLED IN SUIT ABLE AREA: T o insure sufcient ventilation and combustion air supply , proper clearances from the water heater must be maintained. See “Locating the New W ater Heater” section. Combustible materials such as clothing, cleaning materials, or ammable liquids, etc.
28 LEAKAGE CHECKPOINTS Never use this water heater unless it is completely lled with water . T o prevent damage to the tank, the tank must be lled with water . W ater must ow from the hot water faucet before turning “ON” gas to the water heater .
29 Key No. Part Description 1 Pipe Nipple 2 Stamped Steel Burner 2 A Cast Iron Burner 3 Burner T ube (Stamped Burner) 3A Burner T ube (Cast Iron Burner) 4 Orice (Stamped Steel Burner) 4A Orice (.
30 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualied service technician.
31 # LED ST A TUS PROBLEM SOLUTION 7 8 9 Self diagnostic check has detected a problem with the gas valve driver circuit, internal microprocessor , or other internal circuits. 1 T urn the power off for 10-20 seconds then on again to clear these error codes.
32 These guidelines should be utilized by a qualied service agent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES.
33 NOTES:.
34 NOTES:.
35 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater should prove upon examination by the State W ater Heaters (warrantor) to have leaked during th.
36 500 T ennessee Waltz Parkway , Ashland City , TN 37015 www .statewaterheaters.com.
デバイスState Water Heaters GS675HRVITの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
State Water Heaters GS675HRVITをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはState Water Heaters GS675HRVITの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。State Water Heaters GS675HRVITの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。State Water Heaters GS675HRVITで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
State Water Heaters GS675HRVITを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はState Water Heaters GS675HRVITの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、State Water Heaters GS675HRVITに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちState Water Heaters GS675HRVITデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。