SteriliteメーカーS12Qの使用説明書/サービス説明書
ページ先へ移動 of 12
Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t.
T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 .
1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing.
2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter .
3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green.
4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient).
5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open.
6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp.
7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source.
8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life.
9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .
10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.
デバイスSterilite S12Qの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sterilite S12Qをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSterilite S12Qの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sterilite S12Qの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sterilite S12Qで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sterilite S12Qを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSterilite S12Qの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sterilite S12Qに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSterilite S12Qデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。