JA
StorageTek logo
公式取扱説明書

StorageTek SCSI Interface Card (SCSI-3)

45 ページ·379 KB·スイッチ·PDF·EN
StorageTek SCSI Interface Card (SCSI-3)
目次 52セクション Revision History · About This Document · Introduction · How This Guide is Organized · … 表示非表示
Page 1 of the StorageTek SCSI Interface Card (SCSI-3) user manual — 8946121402
1ページ · クリックして拡大
1ページ
StorageTek SCSI Interface Card (SCSI-3) diagram (page 1)
図 1

StorageNet Fibre Channel Switch 4000

SES (SCSI-3 Enclosure Services)

User Guide

8946121402

Page 2 of the StorageTek SCSI Interface Card (SCSI-3) user manual
2ページ · クリックして拡大
2ページ
Page 2 of the StorageTek SCSI Interface Card (SCSI-3) user manual
Page 3 of the StorageTek SCSI Interface Card (SCSI-3) user manual — 8946121402
3ページ · クリックして拡大
3ページ

StorageNet Fibre Channel Switch 4000

SES (SCSI-3 Enclosure Services)

User Guide

8946121402

Page 4 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Revision History
4ページ · クリックして拡大
4ページ

Revision History

Tab Level/DateDescription 01 (08/98)Initial release. 02 (03/99)Manual release corresponding to Release 1.6a.

The U.S. Department of Commerce restricts the distribution of technical information contained in this document when exported outside the U.S. Therefore, careful attention should be given to compliance with all applicable U.S. Export Laws if any part of this document is to be exported.

© 1999 Storage Technology Corporation, Louisville, Co. All rights reserved. Printed in USA.

Address comments concerning this manual to:

StorageTek Technical Communications 7600 Boone Avenue North Minneapolis, MN 55428-1099 USA

Comments may also be submitted over the Internet by addressing them to:

doccomment@network.com

Always include the complete publication number and title of the document with your comments.

ii 8946121402

Page 5 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Reference Documents
5ページ · クリックして拡大
5ページ

About This Document

Introduction

Use this guide for monitoring, configuring, and maintaining a StorageNet Fibre Channel Switch 4000 through SCSI-3 Enclosure Services (SES). You should be knowledgeable about networking in general, routing and bridging in particular. A clearly defined network and security plan is necessary. Your security plan should assess the possible risks to your network and define access policies to deal with those risks.

How This Guide is Organized

This guide is divided into the following chapters:

  • Chapter 1 “Product Overview”, provides an overview of SES and SES Management.
  • Chapter 2 “SES Concepts”, describes the concepts associated with SES.
  • Chapter 3 “SES Commands”, describes FC-PH constructs, FCP and SES commands, and diagnostics pages.
  • Chapter 4 “Troubleshooting”, describes command error messages.

The following appendix is also included in this guide:

  • Appendix A “Glossary”.

Reference Documents

The following documents contain information related to SES:

Fibre Channel Standards. For detailed information on the Fibre Channel standards, see the Fibre Channel Association web site at http://www.fibrechannel.com

StorageNet Fibre Channel Switch 4000 Installation and Reference Guide (8946119902)

StorageNet Fibre Channel Switch 4000 WEB TOOLS User Guide (8946121602)

StorageNet Fibre Channel Switch 4000 ZONING User Guide (8946121502)

8946121402 iii

Page 6 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Customer Support
6ページ · クリックして拡大
6ページ

Notice to the Reader

The material contained in this publication is for informational purposes only and is subject to change without notice. StorageTek is not responsible for the use of any product options or features not described in this publication, and assumes no responsibility for any errors that may appear in this publication. Refer to the revision history (at the beginning of this document) to determine the revision level of this publication.

StorageTek does not by publication of the descriptions and technical documentation contained herein, grant a license to make, have made, use, sell, sublicense, or lease any equipment or programs designed or constructed in accordance with this document or programs designed or constructed in accordance with this information.

Customer Support

For technical support, please call StorageTek at 1-800-248-8777.

Before calling StorageTek, please have your information from the Problem Reporting form ready. This form is located at the back of this manual.

If a problem cannot be resolved through Customer Support, a Return Material Authorization (RMA) is issued. Instructions are provided on where to return the part and how to receive a replacement part. If the product is installed by the customer, the customer is responsible for returning the product with freight paid to the nearest repair center.

iv 8946121402

Page 9 of the StorageTek SCSI Interface Card (SCSI-3) user manual — List of Figures
9ページ · クリックして拡大
9ページ

List of Figures

Figure 1-1 SES Overview 1-2

Figure 2-1 SES Distribution 2-1

Figure 2-2 SES Functional Model 2-2

8946121402 vii

Page 10 of the StorageTek SCSI Interface Card (SCSI-3) user manual — List of Figures
10ページ · クリックして拡大
10ページ

viii 8946121402

Page 11 of the StorageTek SCSI Interface Card (SCSI-3) user manual — List of Tables
11ページ · クリックして拡大
11ページ

List of Tables

Table 1-1 Example LUN Mapping 1-2

Table 2-1 Format of LUN recognized by SESD 2-2

Table 2-2 LUN Mapping 2-2

Table 3-1 Constructs, Commands and Diagnostic Pages 3-1

Table 3-2 FCP Information Unit Descriptions 3-2

Table 3-3 FCP_CMND IU Format 3-3

Table 3-4 FCP_RSP Format 3-3

Table 3-5 FCP_STATUS Format 3-4

Table 3-6 Supported Operation Codes 3-4

Table 3-7 Diagnostics Pages 3-5

Table 3-8 Switch MIB Groups 3-5

Table 3-9 Page Code 0 Format – Supported Diagnostic Pages 3-5

Table 3-10 Switch Page Format 3-6

Table 3-11 Sensor Table Page Format 3-7

Table 3-12 Format of Fabric Page 3-7

Table 3-13 Neighborhood Table Page Format 3-8

Table 3-14 Fibre Channel Port Table Page Format 3-9

Table 3-15 Format of Name Server Local Table Page 3-10

Table 3-16 Inquiry Command Format 3-11

Table 3-17 Inquiry Data Format 3-11

Table 3-18 Page Codes 3-12

Table 3-19 SESD Return Codes for 00h 3-12

Table 3-20 SESD Return Codes for 80h 3-12

Table 3-21 SESD Return Codes for 83h 3-13

Table 3-22 Receive Diagnostic Results Command Format 3-13

Table 3-23 Report LUNs Command Format 3-14

Table 3-24 Reported LUNs Format 3-14

Table 3-25 Request Sense Command Format 3-14

Table 3-26 Send Diagnostic Command Format 3-15

Table 3-27 Test Unit Ready Command Format 3-15

Table 3-28 Reject Command Format 3-16

8946121402 ix

Page 12 of the StorageTek SCSI Interface Card (SCSI-3) user manual — List of Tables
12ページ · クリックして拡大
12ページ

x 8946121402

Page 13 of the StorageTek SCSI Interface Card (SCSI-3) user manual — SES Management
13ページ · クリックして拡大
13ページ

Chapter 1 Product Overview

Introduction

This chapter describes StorageTek’s implementation of SES (SCSI-3 Enclosure Services) on the StorageNet Fibre Channel Switch 4000.

SES implementation in a SCSI-3-based Host Adapter is up to the adapter manufacturer and StorageTek cannot determine their implementation. Therefore, the focus of this guide is to discuss StorageTek’s implementation of SES within the Fabric.

“Reference Documents” for a pointer to the SES Standards Committee’s web site.

SES Management

SES is an in-band mechanism for managing devices, such as switches, within a Fabric or other enclosures. SES commands are used to manage and sense the operational status of the power supplies, cooling devices, displays, indicators, individual drives, and other non-SCSI elements installed in a switch (enclosure). The command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain/set configuration information from the switch.

SES allows a SCSI entity (or initiator) to communicate with a switch through a standard Fiber Channel Protocol (FCP) connection into the Fabric. The benefits are:

  • SES does not require supporting another protocol
  • SES does not require an additional network link (such as Ethernet)

Figure 1-1 shows the Fabric SES view. The switch’s Domain_ID is used as the Logical Unit Number (LUN) address to identify each switch including the switch used for access through SES. See the “SES Functional Model” section in Chapter 2 for more information.

called LUN0. The connection to the well known management address (FFFFFAh) is always labeled LUN0 no matter which switch is used.

8946121402 1-1

Page 14 of the StorageTek SCSI Interface Card (SCSI-3) user manual — 10 010A0000 00000000
14ページ · クリックして拡大
14ページ

Figure 1-1 SES Overview

StorageTek SCSI Interface Card (SCSI-3) — Chapter 1 Product Overview diagram (page 14)
図 2 · Chapter 1 Product Overview

LUN addressing within the Fabric can be non-sequential because it is based on the switch’s Domain_ID. Table 1-1 shows the sample LUN mapping used with Figure 1-1.

Table 1-1 Example LUN Mapping

Domain ID Unique LUN Value (in Hex)

5 00000000 00000000 (Note that Domain ID 5 is used for both LUN 0 and 5)

10 010A0000 00000000

Figure 1-1 shows that the switch in the lower left hand corner is assigned both LUN5 and LUN0. (LUN5 because the switch’s Domain_ID is 5 and LUN0 because the client is physically connected to that switch.) LUN values for the first byte, shown in Table 1-1, are:

  • 00 000000 00000000 - the bold characters indicate the local switch
  • 0X0X 0000 00000000 - the bold characters indicate the SCSI LUN address of the other switches in the Fabric
Show 6 more labels / short text on this page
SES Management · 2 01020000 00000000 · 5 01050000 00000000 · 6 01060000 00000000 · 9 01090000 00000000 · 1-2 8946121402
Page 15 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Chapter 1 Product Overview
15ページ · クリックして拡大
15ページ

Therefore, if there are 5 switches in the Fabric SES reports 6 LUNs, one LUN value for each switch and LUN0 for the local client connection.

Other SCSI-3 enclosures can also run SES outside the Fabric, such as JBODs, RAID-5 arrays, SCSI-3 hard drives, and SCSI-3 tape drives. These devices are identified by their Fabric and SCSI addresses, and are assigned LUNs using standard SCSI-3 host adapter LUN addressing.

SES Management · 8946121402 1-3

Page 16 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Chapter 1 Product Overview
16ページ · クリックして拡大
16ページ

SES Management · 1-4 8946121402

Page 17 of the StorageTek SCSI Interface Card (SCSI-3) user manual — SES Functional Model
17ページ · クリックして拡大
17ページ

Chapter 2 SES Concepts

Introduction

This chapter uses generic terms to describe enclosure services and specific SES implementation. SES instances can be distributed inside and outside of the Fabric to any enclosure capable of supporting enclosure services through an SES device.

SES is distributed transparently throughout the Fabric, with an instance of a distributed SES Device (SESD) on each switch as shown in Figure 2-1.

Figure 2-1 SES Distribution

StorageTek SCSI Interface Card (SCSI-3) — Chapter 2 SES Concepts diagram (page 17)
図 3 · Chapter 2 SES Concepts

SES Functional Model

Each instance may be accessed by an SES Application Client by specifying the associated unique LUN. See Figure 2-2 for information on LUN addressing. SES implementation also provides an SES Application Client an in-band mechanism for managing any Fabric switch that it is attached to.

Figure 2-2 shows the SES functional model.

8946121402 2-1

Page 18 of the StorageTek SCSI Interface Card (SCSI-3) user manual — FC-PH
18ページ · クリックして拡大
18ページ

Figure 2-2 SES Functional Model

FC-PH

FC-PH

At the Fibre Channel level, each SESD is accessible through the Fibre Channel well known address, FFFFFAh (Management Server). At the SCSI-3 level, it is associated with a LUN. An SES Application Client can refer to any distributed SESD within the Fabric using its LUN. A LUN value of 0 is always associated with the local switch that is physically attached to the SES Application Client. The unique LUN value is mapped based on peripheral device addressing.

The bus number for each switch is set to 010000b as shown in Table 2-1. The first byte of the Target/LUN is set using the Domain_ID of the switch. Bytes 2..7 are set to zero.

Table 2-1 Format of LUN recognized by SESD

Byte/Bit 7 6 5 4 3 2 1 0

0 0 0 Bus Number = 010000b

... or

7 Logical Unit Number (LUN)

Table 2-2 shows the LUN mapping.

Table 2-2 LUN Mapping

Domain ID Unique LUN Value (in Hex)

0 0h 01000000 00000000

5 5h 01050000 00000000

12 Ch 010C0000 00000000

15 Eh 010F0000 00000000

25 19h 01190000 00000000

Show 14 more labels / short text on this page
SES Functional Model · SES Application · SES Request · Client · SES Response · SES Device · FCP Command · FCP Port · FCP _Port · FCP Response · Request Sequence · Response Sequence · 1 Target · 2-2 8946121402
Page 19 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Indicators and Control Management
19ページ · クリックして拡大
19ページ

Access to the Enclosure Services Process

An SES Application Client may easily find the LUN values of all distributed SESDs inside the Fabric by using the Report LUNs command. See the “Report LUNs” section in Chapter 3 for more information.

Access to the Enclosure Services Process

An application client can monitor all enclosures capable of processing the enclosure services command set with SES instances distributed throughout a Storage Area Network (SAN). Enclosure services can monitor both devices inside and outside of the enclosure, such as an Uninterruptable Power Supply (UPS). However, SES pertains only to SES instances inside the Fabric.

An application client connects through Fiber Channel Protocol (FCP) using the Management Service address (FFFFAh) to any switch through its LUN. See Figure 1-1. The enclosure services command set uses the RECEIVE DIAGNOSTIC RESULTS and SEND DIAGNOSTIC commands to any device capable of supporting SES.

Access Through an Enclosure Services Device

The Application Client requests information from the SESD to examine status and warning information from the switch.

An Application Client through FCP calls the enclosure services process running on any switch as a LUN that has SES enabled. The SESD sets the enclosure services bit (EncServ) in the INQUIRY command to indicate that it can transport enclosure services information. See the “Inquiry” section in Chapter 3 for more information.

Indicators and Control Management

SESD is accessed through an application client that uses the SEND DIAGNOSTIC command to transport control information to the enclosure services process. The control information may include operations to perform or to modify its operating mode. The application client uses the RECEIVE DIAGNOSTIC RESULTS command with the PF bit set to obtain enclosure status. The information returned indicates the actual enclosure state. See the “Receive Diagnostic Results” section in Chapter 3 for more information.

enclosure service processor to ensure proper state information. For example, the enclosure may ignore an instruction to clear an error condition because the condition is valid or because the instruction is not supported by the enclosure.

8946121402 2-3

Page 20 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Access to the Enclosure Services Process
20ページ · クリックして拡大
20ページ

Indicators and Control Management

2-4 8946121402

Page 21 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Constructs, Commands and Diagnostic Pages
21ページ · クリックして拡大
21ページ

Chapter 3 SES Commands

Introduction

This chapter contains information and examples on managing SES, including the following:

  • FC-PH constructs
  • Diagnostics pages

Constructs, Commands and Diagnostic Pages

Table 3-1 summarizes the FC-PH constructs, FCP commands, and SES commands.

Table 3-1 Constructs, Commands and Diagnostic Pages

FCP Information Unit SCSI Command to be executed or a task management request.

FCP Transfer Ready Information Unit

Contains SCSI-3 data delivery service parameters.

FCP Data Information Unit Transfers data.

FCP Response Information Unit

Contains status and sense information.

Supported Diagnostics Pages Contains the diagnostic pages supported.

Switch Page Contains status information about the switch, its operational state and firmware.

Sensor Table Page Contains status information about the state of all sensors in the switch.

Fabric Page Contains information about the Fabric, its neighbors and domain_ID.

Neighborhood Table Page Contains information about the switch’s neighbors in the Fabric.

Fibre Channel Port Table Page Contains information about the switch’s Fibre Channel ports.

Name Server Local Table Page Contains information about the SESD.

Inquiry Contains information about the devices and sensors in an enclosure.

Receive Diagnostics Results Contains information returned by the SESD about an enclosure.

Command Description · 8946121402 3-1

Page 22 of the StorageTek SCSI Interface Card (SCSI-3) user manual — FCP Command Information Unit
22ページ · クリックして拡大
22ページ

Table 3-1 Constructs, Commands and Diagnostic Pages (Continued)

Report LUNs Contains information returned from SESD containing the LUNs attached to the SESD.

Request Sense Used to sense information from the SESD.

Send Diagnostic Used to configure/diagnose a logical unit.

Test Unit Ready Used to test an LUNs operation state.

Reject Contains information and status about a unit’s failure.

FCP Constructs

Before initiating any FCP request, the Nx_Port associated with the SES Application Client (FCP Initiator) must complete an N_Port Login (PLOGI) with the Management Server in Class 2 or 3.

Process Login (PRLI) is not required by the SESD.

The format of an FCP Command (FCP_CMND), FCP Transfer Ready (FCP_XFER_RDY), FCP Data (FCP_DATA) and FCP Response (FCP_RSP) conforms to those defined in the SCSI-3 Fibre Channel Protocol (FCP), Revision 12, X3T10/269, working draft.

Table 3-2 gives a brief description of the FCP Information Unit.

Table 3-2 FCP Information Unit Descriptions

FCP Information Unit Description

FCP_CMND The Information Unit contains a SCSI Command to be executed or a task management request on a target.

FCP_XFER_RDY The Information Unit indicates that the target is ready to perform the data transfer associated with a FCP_CMD.

FCP_DATA The data associated with an I/O operation.

FCP_RSP The Information Unit contains status and sense information

FCP Command Information Unit

Table 3-3 shows the FCP_CMND Information Unit (IU) that carries either a SCSI command to be executed or a task management request to be performed. It contains the values and control fields defined in its payload.

FCP Constructs · Command Description · 3-2 8946121402

Page 23 of the StorageTek SCSI Interface Card (SCSI-3) user manual — FCP Response Information Unit
23ページ · クリックして拡大
23ページ

Table 3-3 FCP_CMND IU Format

Byte Size Field Name Byte Number Description

8 FCP_LUN 0 - 7 Logical Unit Number

4 FCP_CNTL 8 - 11 Control flags and bits for task/execution management

16 FCP_CDB 12 - 27 SCSI command descriptor block

4 FCP_DL 28 - 31 Data Length

The FCP_LUN value format is described in Table 3-3 or the value is 0. The latter refers to the SESD on the local switch. The FCP_CNTL value is set to 1, 2 or 0 depending on whether READ DATA, WRITE DATA or neither is involved in the command. The FCP_CDB value contains the appropriate command descriptor. The FCP_DL field contains a count of the maximum number of data bytes to be transferred to or from the target for the command.

FCP Transfer Ready Information Unit

The FCP_XFER_RDY Information Unit contains SCSI-3 data delivery service parameters required by the initiator and must be transmitted preceding each read or write FCP_DATA IU.

FCP Data Information Unit

The FCP_DATA Information Unit transfers the actual data.

FCP Response Information Unit

Table 3-4 shows the FCP_RSP that carries the response status and sense information associated with a particular FCP_CMND.

Table 3-4 FCP_RSP Format

Byte Size Field Name Description

4 FCP_STATUS Status of the (linked/previous) request

4 FCP_RESID Residual Count

4 FCP_SNS_LEN Length of Sense Information (FCP_SNS_INFO)

4 FCP_RSP_LEN Length of Response Information (FCP_RSP_INFO)

m FCP_RSP_INFO FCP Response Information

n FCP_SNS_INFO SCSI Sense Information

FCP Constructs · 8 Reserved Reserved · 8946121402 3-3

Page 24 of the StorageTek SCSI Interface Card (SCSI-3) user manual — 3 FCP_RESID_UNDER
24ページ · クリックして拡大
24ページ

Table 3-5 shows the FCP_STATUS field format.

Table 3-5 FCP_STATUS Format

0 7 .. 0 Reserved

1 7 .. 0 Reserved

7 .. 4 Reserved

3 FCP_RESID_UNDER

2 FCP_RESID_OVER

1 FCP_SNS_LEN_VALID

0 FCP_RSP_LEN_VALID

3 7 .. 0 SCSI status byte from the SCSI logical unit (not used)

The reserved bits are set to 0 by the SESD. FCP_RESID_UNDER indicates that the FCP_RESID field is valid and contains the number of bytes expected to be transferred, but were not transferred. See Table 3-4. This bit is not used by SESD. FCP_RESID_OVER indicates that the FCP_RESID field is valid and contains the number of bytes that have been truncated because the FCP_DL was not sufficient. See Table 3-3. This bit may be set by SESD.

Table 3-6 shows the commands supported by SESD.

Table 3-6 Supported Operation Codes

Receive Diagnostics Results 1Ch

Test Unit Ready 00h

The value of the FCP_LUN field in FCP_CMND specifies the logical unit for the request in each command. The value of FCP_DL field in FCP_CMND specifies whether there is any data parameter to be transferred to the SESD. The value should be 0 for command 1, 2, 3, 4 and 6. For command 5, the value may be 0 or the size of a diagnostic page whose page code is in the range of 80h through 85h.

Show 7 more labels / short text on this page
Byte Bit Definition · Command Operation Code · Inquiry 12h · Report LUNs A0h · Request Sense 03h · Send Diagnostic 1Dh · 3-4 8946121402
Page 25 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Supported Diagnostics Pages
25ページ · クリックして拡大
25ページ

Switch Diagnostics Pages

Before each SCSI command is discussed in detail, the diagnostics pages are defined in Table 3-7. They are particularly relevant to two commands: Receive Diagnostic Results and Send Diagnostics. The switch SESD supports 7 diagnostics pages.

Table 3-7 Diagnostics Pages

00h Supported Diagnostics Pages

81h Sensor Table Page

83h Neighborhood Table Page

84h Fibre Channel Port Table Page

85h Name Server Local Table Page

Table 3-8 shows the page codes 80h through 85h which are vendor specific pages and are roughly mapped from the switch Management Information Base (MIB) Definition for v1.6a firmware.

Table 3-8 Switch MIB Groups

Page Code Switch MIB Group

80h System Group, variables 1..8, 20, 21

81h System Group, Sensor Table

82h Fabric Group, variables 1, 2 and 8

83h Fabric Group, Neighborhood Table

84h Fibre Channel Port Table

85h Name Server Local Table

Supported Diagnostics Pages

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-9

Table 3-9 Page Code 0 Format – Supported Diagnostic Pages

Byte/Bit 7 6 5 4 3 2 1 0

0 Page Code = 00h

Show 5 more labels / short text on this page
Page Code Description · 80h Switch Page · 82h Fabric Page · 1 Reserved · 8946121402 3-5
Page 26 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Switch Page
26ページ · クリックして拡大
26ページ

Table 3-9 Page Code 0 Format – Supported Diagnostic Pages (Continued)

Byte/Bit 7 6 5 4 3 2 1 0

2 (MSB)

Page Length = 7 (LSB) 3

Switch Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-10.

Table 3-10 Switch Page Format

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 80h

1 na na Reserved

2 .. 3 na na Page Length = 404

4 .. 7 na na swValid

8 .. 71 0 ro Current_Date (in ASCII text)

72 .. 135 1 ro Boot_Date (in ASCII text)

136 .. 199 2 ro Firmware_Last_Updated_Date (in ASCII text)

200 .. 263 3 ro FLASH_Last_Updated_Date (in ASCII text)

264 .. 327 4 ro Boot_PROM_Last_Updated_Date (in ASCII text)

328 .. 391 5 ro Firmware_Version_Information (in ASCII text)

392 .. 395 6 ro Switch_Operational_Status

396 .. 399 7 rw Switch_Administrative_Status

400 .. 403 8 ro Diagnostics_Result

404 .. 407 9 ro Number_of_Sensors

Show 8 more labels / short text on this page
4 00h · 5 80h · 6 81h · 7 82h · 8 83h · 9 84h · 10 85h · 3-6 8946121402
Page 27 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Fabric Page
27ページ · クリックして拡大
27ページ

The field swValid is bit mapped and indicates which subsequent fields within the page are valid. The bit position for subsequent fields starts from 0, as indicated in the Field # column of Table 3-10. For example, if the fields: Current_Date, Boot_Date and Number_of_Sensors are valid, it contains the hex value of 0003h.

Sensor Table Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-11.

Table 3-11 Sensor Table Page Format

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 81h

1 na na Reserved

2 .. 3 na na Page Length = n - 3

4 .. 7 na na swNumEntries = i – specifies the number of entries received for bytes 8 -91, if the number is 5 there are 5 complete outputs for byte 8 - 91.

8 .. 11 na ro swValidity[0]

12 .. 15 0 ro swSensorIndex[0]

16 .. 19 1 ro swSensorType[0]

20 .. 23 2 ro swSensorStatus[0]

24 .. 27 3 ro swSensorValue[0]

28 .. 91 4 ro swSensorInfo[0]

more instances of swSensorEntry (swValidity .. swSensorInfo) if applicable ...

(n-64)..(n-1) 4 ro swSensorInfo[i-1]

Fabric Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-12.

Table 3-12 Format of Fabric Page

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 82h

1 na na Reserved

2 .. 3 na na Page Length = 20

4 .. 7 na na swValid

8 .. 11 0 ro swDomainID

8946121402 3-7

Page 28 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Fibre Channel Port Table Page
28ページ · クリックして拡大
28ページ

Table 3-12 Format of Fabric Page (Continued)

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

12 .. 15 1 ro PrincipalSwitchFlag

16 .. 19 2 ro NumberOfImmediateNeighbor

20 .. 23 3 ro NumberOfFabricISL_Entries

Neighborhood Table Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-13.

Table 3-13 Neighborhood Table Page Format

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 83h

1 na na Reserved

2 .. 3 na na Page Length = n - 3

4 .. 7 na na swNumEntries = i – specifies the number of entries received for bytes 8. Note that each entry consists of swValidity[0] field through field 5.

8 .. 11 na rw swValidity[0]

12 .. 15 0 ro swNbIndex[0]

16 .. 19 1 ro NswNbMyPort[0]

20 .. 23 2 ro swNbRemoteDomainID[0]

24 .. 27 3 ro swNbRemotePort[0]

28 .. 31 4 ro swNbBaudRate[0]

32 .. 35 5 ro swNbIslState[0]

more instances of swNbEntry (swValidity .. swNbIslState) if applicable ...

(n-4)..(n-1) 0 - 5 ro swNbIslState[i-1]

Fibre Channel Port Table Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-14.

3-8 8946121402

Page 29 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Neighborhood Table Page
29ページ · クリックして拡大
29ページ

Table 3-14 Fibre Channel Port Table Page Format

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 84h

1 na na Reserved

2 .. 3 na na Page Length = n - 3

4 .. 7 na na swNumEntries = i – specifies the number of entries received. Note: Each entry consists of swValidity[0] field through field 27.

8 .. 11 na rw swValidity[0]

12 .. 15 0 ro swFCPortIndex[0]

16 .. 19 1 ro swFCPortType[0]

20 .. 23 2 ro swFCPortPhyStatus[0]

24 .. 27 3 ro swFCPortOpStatus[0]

28 .. 31 4 rw swFCPortAdmStatus[0]

32 .. 35 5 ro swFCPortTxWords[0]

36 .. 39 6 ro swFCPortRxWords[0]

40 .. 43 7 ro swFCPortTxFrames[0]

44 .. 47 8 ro swFCPortRxFrames[0]

48 .. 51 9 ro swFCPortTxC2Frames[0]

52 .. 55 10 ro swFCPortTxC3Frames[0]

56 .. 59 11 ro swFCPortRxLCs[0]

60 .. 63 12 ro swFCPortRxMcasts[0]

64 .. 67 13 ro swFCPortTooManyRdys[0]

68 .. 71 14 ro swFCPortNoTxCredits[0]

72 .. 75 15 ro swFCPortRxEncInFrs[0]

76 .. 79 16 ro swFCPortRxCrcs[0]

80 .. 83 17 ro swFCPortRxTruncs[0]

84 .. 87 18 ro swFCPortRxTooLongs[0]

88 .. 91 19 ro swFCPortRxBadEofs[0]

92 .. 95 20 ro swFCPortRxEncOutFrs[0]

96 .. 99 21 ro swFCPortRxBadOs[0]

100 .. 103 22 ro swFCPortRxC3Discards[0]

104 .. 107 23 ro swFCPortMcastTimedouts[0]

8946121402 3-9

Page 30 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Name Server Local Table Page
30ページ · クリックして拡大
30ページ

Table 3-14 Fibre Channel Port Table Page Format (Continued)

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

108 .. 111 24 ro swFCPortTxMcasts[0]

112 .. 115 25 ro swFCPortLipIns

116 .. 119 26 ro swFCPortLipOuts

120 .. 123 27 ro swFCPortLipLastAlpa

more instances of swFCPortEntry (swValidity .. swFCPortTxMcasts) if applicable ...

(n-4)..(n-1) 0 - 27 ro swFCPortLipLastAlpa[i-1]

Name Server Local Table Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the following response as shown in Table 3-15.

Table 3-15 Format of Name Server Local Table Page

Byte/Bit Field # Access 7 6 5 4 3 2 1 0

0 na na Page Code = 85h

1 na na Reserved

2 .. 3 na na Page Length = n - 3

4 .. 7 na na swNumEntries = i – Note that each entry consists of swValidity[0] field through field 10.

8 .. 11 na ro swValidity[0]

12 .. 15 0 ro swNsIndex[0]

16 .. 19 1 ro swNsPortType[0]

20 .. 23 2 ro swNsPortID[0]

24 .. 31 3 ro swNsPortName[0]

32 .. 287 4 ro swNsPortSymbolicName[0]

288 .. 295 5 ro swNsNodeName[0]

296 .. 551 6 ro swNsNodeSymbolicName[0]

552 .. 559 7 ro swNsInitialProcessInitiator[0]

560 .. 575 8 ro swNsClassOfServices[0]

576 .. 579 9 ro swNsClassOfServices[0]

580 .. 643 10 ro swNsFc4Types[0]

more instances of swNsLocalEntry (swValidity..swNsFc4Types) if applicable ...

(n-4)..(n-1) 0 - 10 ro swNsFc4Types[i-1]

3-10 8946121402

Page 31 of the StorageTek SCSI Interface Card (SCSI-3) user manual — VS=0
31ページ · クリックして拡大
31ページ

Inquiry

An SES Application Client may send an Inquiry command to obtain information about a switch in the Fabric. The format of the FCP_CDB is shown in Table 3-16.

Table 3-16 Inquiry Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = 12h

1 Reserved CmdDt=0 EVPD=0

2 Page Code = 0

5 Control = 0

If the field, EVPD (Enable Vital Product Data) is set to 0 and the value of the page code is 0, the standard Inquiry Data is returned as shown in Table 3-17.

Table 3-17 Inquiry Data Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Peripheral Qualifier = 0 Peripheral Device Type = 0Dh

1 RMB= 0 Reserved = 0

2 ISO version = 0 ECMA version = 0 ANSI version = 3

3 AERC =0

TrmTsk= 0 NormAC A=1

Response data format = 2

4 Additional Length = 31 (1Fh)

VS = 0 MultiP =1Bh

ACKREQ Q=0

Sync= 0 Linked= 0 Trandis= 0 CmdQu e=0

VS=0

8 ..15 Vendor identification = ”STORAGETEK”

16. 31 Product identification = “Switch”
32. 35 Product revision level = “v{N}.{m}{p”” (where {N} is a single number designating the major release number, {m} is a single number designating the minor release number), and {p} is a single alpha character designating a patch. There may be a space indicating there’s no patch. For example, v1.5a
Show 13 more labels / short text on this page
3 Reserved · 4 Allocation Length · Reserv ed=0 · 5 Reserved · 7 Reser ved · EncServ =1Bh · MChngr =0 · Addr32 =0 · Addr16 =0 · 7 RelAdr =0 · WBus32 =0 · Wbus16 =0 · 8946121402 3-11
Page 32 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Inquiry
32ページ · クリックして拡大
32ページ

If the field, EVPD is set to 1, then the value of the page code may be set to one of the codes shown in Table 3-18.

Table 3-18 Page Codes

00h Supported vital product data pages

80h Unit Serial Number Page

83h Device Identification Page

If the page code is set to 00h, the SESD will return codes shown in Table 3-19.

Table 3-19 SESD Return Codes for 00h

Byte/Bit 7 6 5 4 3 2 1 0

0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh

1 Page Code = 00h

3 Page length = 3

If the page code is set to 80h, the SESD will return codes shown in Table 3-20.

Table 3-20 SESD Return Codes for 80h

Byte/Bit 7 6 5 4 3 2 1 0

0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh

1 Page Code = 80h

3 Page length = 24

4 Product Serial Number = the switch World_wide Name in ASCII string format E.g. “10:00:00:60:69:00:01:b4 ” ...

Show 7 more labels / short text on this page
Page Code Description · 2 Reserved · 4 00h · 5 80h · 6 83h · 2 Reserved · 3-12 8946121402
Page 33 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Receive Diagnostic Results
33ページ · クリックして拡大
33ページ

If the page code is set to 83h, the SESD will return codes shown in Table 3-21.

Table 3-21 SESD Return Codes for 83h

Byte/Bit 7 6 5 4 3 2 1 0

0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh

1 Page Code = 83h

3 Page length = 32

4 Reserved = 0 Code set = 2

5 Reserved = 0 Identifier type = 1

6 Reserved = 0

7 Identifier length = 28

8 Identifier = Vendor Identification (8 bytes) + Product identification (16 bytes) + Product revision level (4 bytes) See Table 3-17

Receive Diagnostic Results

An SES Application Client sends a Receive Diagnostic Results command to return diagnostic or management data. The FCP_CDB format is shown in Table 3-22.

Table 3-22 Receive Diagnostic Results Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = 1Ch

3 .. 4 Allocation Length

5 Control = 0

A Page Code Valid (PCV) bit of zero indicates that the most recent Send Diagnostic command defines the data returned by this command. A value of 1 indicates that the Page Code field defines the data to be returned for this command. The page codes and formats are defined in the “Switch Diagnostics Pages” section.

Show 4 more labels / short text on this page
2 Reserved · 1 Reserved PCV · 2 Page Code · 8946121402 3-13
Page 34 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Request Sense
34ページ · クリックして拡大
34ページ

Report LUNs

An SES Application Client sends a Report LUNs command to obtain the number of logical units (each is a switch in SCSI impersonation) in the Fabric. The CDB format is shown in Table 3-23.

Table 3-23 Report LUNs Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = A0h

1 .. 5 Reserved

6 .. 9 Allocation Length

11 Control = 0

The SESD reports the LUNs of associated switches with the format shown in Table 3-24.

Table 3-24 Reported LUNs Format

Byte/Bit 7 6 5 4 3 2 1 0

0 .. 3 LUN list length (n-7)

4 .. 7 Reserved

8 .. 15 LUN

(n-7)..n LUN

Request Sense

An SES Application Client sends a Request Sense command to obtain sense data. The CDB format is shown in Table 3-25.

Table 3-25 Request Sense Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = 03h

1 .. 3 Reserved

5 Control = 0

The SESD returns a sense key of NO SENSE and an additional sense code of NO ADDITIONAL SENSE INFORMATION.

10 Reserved · 4 Allocation length · 3-14 8946121402

Page 35 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Test Unit Ready
35ページ · クリックして拡大
35ページ

Send Diagnostic

A SES Application Client can use a Send Diagnostic command to configure/diagnose a logical unit. After the command completion, the SES Application Client sends a Receive Diagnostic Results command. See Table 3-22. The FCP_CDB format is shown in Table 3-26.

Table 3-26 Send Diagnostic Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = 1Dh

1 Reserved PF Reserved selfTest DevOfL UnitOfL

3 .. 4 Parameter list length

5 Control = 0

A Page Format (PF) bit of 1 specifies that the Send Diagnostic parameters conform to the page structure as specified in SCSI-3 Primary Command (SPC), Revision 11a, X3T10/995D, working draft. A value of 0 specifies that all parameters are vendor specific. At present, the SESD only supports the vendor-specific page structures as defined in the “Switch Diagnostics Pages” section.

The selfTest, DevOfL and UnitOfL bits are ignored by the SESD at present.

The Parameter List Length field specifies the length in bytes of the parameter list that shall be transferred from the SES Application client to the SESD.

Test Unit Ready

An SES Application Client sends a Test Unit Ready command to check if the logical unit is ready. The FCP_CDB format is shown in Table 3-27.

Table 3-27 Test Unit Ready Command Format

Byte/Bit 7 6 5 4 3 2 1 0

0 Operation Code = 00h

1 .. 4 Reserved

5 Control = 0

The SESD returns the status of GOOD and CHECK CONDITION and a sense key of NO SENSE and an additional sense code of NO ADDITIONAL SENSE INFORMATION.

2 Reserved · 8946121402 3-15

Page 36 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Reject
36ページ · クリックして拡大
36ページ

Reject

The SESD issues a Reject command to set status to Check Condition and the appropriate values for the Sense Key (SK) field. Additional Sense Code (ASC) and Additional Sense Code Qualifier (ASCQ) values are as shown in Table 3-28.

Table 3-28 Reject Command Format

SK ASC ASCQ Explanation

2 04h 0 Logical Unit not ready

2 35h 0 Enclosure Service failed

2 35h 2 Enclosure Service unavailable (memory allocation problem)

5 1Ah 0 Parameter List length error (too small or too big)

5 20 0 Invalid command operation code

5 20 0 Logical Unit not supported (invalid LUN value in FCP_CDB)

3-16 8946121402

Page 37 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Invalid Field Errors
37ページ · クリックして拡大
37ページ

Chapter 4 Troubleshooting

Introduction

This chapter discusses the SEND DIAGNOSTIC command error messages.

License Reject

A license reject is generated when the SES license key is improperly entered or is not installed.

The following message is generated:

Probable cause: Invalid Field Action: See the “Reject” section in Chapter 3 for more information.

CHECK CONDITION

CHECK CONIDITION is generated when the SES Device (SESD) terminates an operation because an error was encountered. These error conditions can be from invalid operations, warning indications and failure conditions. The sense key and sense code describe the error.

Invalid Field Errors

ILLEGAL REQUEST is generated from any invalid fields in the CDB, from parameters of a SEND DIAGNOSTIC command and from the CDB of a RECEIVE DIAGNOSTIC RESULTS command. The sense code identifies the location of the invalid fields, parameter or CDB.

The following message is generated:

Probable cause: Invalid Field Action: See the “Reject” section in Chapter 3 for more information.

8946121402 4-1

Page 38 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Chapter 4 Troubleshooting
38ページ · クリックして拡大
38ページ

Introduction · 4-2 8946121402

Page 39 of the StorageTek SCSI Interface Card (SCSI-3) user manual — 8946121402 A-1
39ページ · クリックして拡大
39ページ

Appendix A Glossary

Application ClientThe source object of the SCSI commands and destination for the

command responses.

Byte: A group of 8 bits.

Command Descriptor BlockThe structure of up to 16 bytes in length used to communicate

commands from the application client to a device server.

Critical ConditionAn enclosure condition where one or more elements inside the enclosure

have failed or are outside of operational parameters. The element failure makes normal operation of at least some elements in the enclosure impossible, although some of the elements inside the enclosure may be able to continue normal operation.

Device: A mechanical, electrical or electronic part in an enclosure.

Device Server: A logical unit object that executes SCSI tasks.

Device Service RequestA request from an application client of SCSI commands to a device

server.

Device SlotAn insertion position in an enclosure for SCSI devices. The position provides

power, signal and control connections for the SCSI device. The position may also provide protection, automatic insertion, device status LEDs, locking capability, and additional features to manage SCSI devices in the enclosure.

Device Type: The device type or device model implemented by the device server.

Domain_IDThe domain number uniquely identifies the switch in a Fabric. Normally the

switch domain ID is automatically assigned by the principal switch and may be any value between 0 and 31. This number may also be assigned manually.

EnclosureThe box, rack or box set that provide power, mechanical protection, external

interfaces and cooling for the SCSI device(s).

Enclosure ServicesThe services that establishes indictors and controls for the proper

operation and maintenance of devices within the enclosure.

Enclosure Services Device: A SCSI device that monitors and controls enclosure services.

The switches imbedded port.

InitiatorA SCSI device containing application clients that originate device service requests

to be processed by the device servers.

8946121402 A-1

Page 40 of the StorageTek SCSI Interface Card (SCSI-3) user manual — A-2 8946121402
40ページ · クリックして拡大
40ページ
Logical UnitA target-resident entity that implements a device model and executes SCSI

commands originated by an application client.

Logical Unit NumberA device or element known by an enclosure that identifies it to the

application client.

RedundancyThe presence in an enclosure of one or more elements capable of automatically

taking over the functions of a failed element.

SCSI: Small Computer Systems Interface.

SCSI DeviceA device that is connected to a service delivery subsystem and supports the

SCSI application protocol.

TargetA SCSI device that receives SCSI commands and directs such commands to one or

more logical units for execution.

A-2 8946121402

Page 43 of the StorageTek SCSI Interface Card (SCSI-3) user manual — COMMENTS:
43ページ · クリックして拡大
43ページ

Comment Sheet

StorageTek welcomes your comments about this publication. Please complete this form, including your name and address, and mail it to StorageTek, Technical Communications Department, 7600 Boone Avenue North, Minneapolis, Minnesota, 55428-9919, USA.

Comments may also be submitted over the Internet by addressing them to:

doccomment@network.com

Always include the complete publication number and title of the document with your comments.

Name:

Company:

Address:

City, State: Zip Code:

Publication Number and Revision_____________________________________________

Publications Title:

COMMENTS:

Page 44 of the StorageTek SCSI Interface Card (SCSI-3) user manual — FIRST CLASS MAIL PERMIT NO. 19774 MPLS, MN
44ページ · クリックして拡大
44ページ

FOLD 1ST FOLD 1ST

NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES

BUSI NESS REPLY MAIL

FIRST CLASS MAIL PERMIT NO. 19774 MPLS, MN

POSTAGE WILL BE PAID BY ADDRESSEE

ATTN: TECHNICAL COMMUNICATIONS DEPARTMENT

STORAGETEK

7600 BOONE AVENUE NORTH MINNEAPOLIS, MN 55428-9919

FOLD FOLD

CUT ON VERTICAL LINE

TAPE TAPE DO NOT STAPLE

Page 45 of the StorageTek SCSI Interface Card (SCSI-3) user manual — Please record the following information for future reference:
45ページ · クリックして拡大
45ページ

StorageTek Problem Reporting

Please direct any product-related problems or complaints to the following toll-free telephone number: 1-800-248-8777

Please be aware that, depending on your maintenance and/or warranty coverage, the services delivered may be chargeable.

This form is provided for your convenience in gathering information for your call. Make as many copies as you wish. Please have the following information available when reporting a problem:

Serial Number (Hardware Products only)

Product being reported on

Call back Telephone Number

(Include error messages or other supporting documentation.)

Impact on Customer Operations

(Is the problem an annoyance, minor interruption, or severe impact on your operations?)

Please record the following information for future reference:

Customer Problem Number (if assigned) StorageTek Problem Number

Date Reported Time Reported

Show 6 more labels / short text on this page
Site ID · Customer Name · (BorderGuard, RDS) · Customer Contact · Problem Description · Comments
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

StorageTek SCSI Interface Card (SCSI-3)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
StorageTek SCSI Interface Card (SCSI-3)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

StorageTek SCSI Interface Card (SCSI-3) 取扱説明書(PDF)

45 ページ·379 KB·スイッチ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…