StovaxメーカーRV66の使用説明書/サービス説明書
ページ先へ移動 of 38
PM235 - Issue 1 (May 2008) Riva MF Cassette MODELS: RV40/RV55/RV66/RV66AVC/RV76 Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland).
COVERING THE FOLLOWING MODELS: RV40/RV55/RV66/RV66AVC/RV76 2 APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 General Points 4 Using the Appliance for the first time 6 Recommended Fuels 6 Light.
3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Dealer appliance was purchased from Name: .............................................................................................
4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.
5 USER INSTRUCTIONS 4) Clean burn - Secondary air is preheated through a heat exchanger to combust unburned hydrocarbons, providing a cleaner and more efficient burn.
6 USER INSTRUCTIONS 1.16 Riva 66 Avanti To open and close the door: •Use the tool provided, see Diagram Remove Pull to open RIVA Lift to Open Remove RIVA AVANTI PR7049 WARNING Properly installed, operated and maintained this appliance will not emit fumes into the room.
7 USER INSTRUCTIONS 3.2 Solid fuel: •Burn only anthracite or manufactured briquette smokeless fuels listed as suitable for use with closed heating appliances Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this will invalidate the product guarantee .
8 USER INSTRUCTIONS 5.6 Burning Solid fuel (Not applicable for Riva 76) : •Setaircontr ols ,SeeDia gra m PRIMARY AIR CONTROL AIRWASH AIR CONTROL PR7003 PR7034 RIVA PRIMARY AIR CONTROL AIRWASH AIR CONTROL PR7047 PR7048 RIVA AVANTI Open Fully Open Fully Open 25% Open 25% 5.
9 USER INSTRUCTIONS 6. BURNING TIPS 6.1 Fuel Quality (Wood) Use wood with a moisture content of less than 20%. Seasoned logs have the bark beginning to lift and peel away and cracks radiating from the centre. They feel lighter than fresh cut wood of a similar size and sound hollow when struck against each other.
10 7. ASH REMOVAL 7.1 All fuels: •Open Ash pan Cover (Riva 66 only), See Diagram 8 8 Riva Ashpan Cover Riva Avanti PR7051 9 •Remove Ashpan carefully.
11 14. CARE OF STOVE Stovax has a range of cleaning and maintenance products and accessories to keep your appliance in good working condition. Your Stovax retailer can provide full details but here is.
12 •Glass blackening •Thick, brown and sticky tar oozes from the pipe joints This is caused by burning damp wood and burning your appliance at too low a.
13 TECHNICAL SPECIFICATION STANDARD FEATURES • Primary air (under grate air for full multifuel use) • Airwash (for woodburning/ clean glass) • Pre-se.
14 RIVA DIMENSIONS All dimensions in mm. (25.4 mm = 1”) TECHNICAL SPECIFICATION * * Riva Riva Avanti PR7041 Riva 40 RV40 Riva 55 RV55 Riva 66 RV66 Riva 66 Avanti RV66 AVC Riva 76 RV76 A 400mm 540mm .
15 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks.
16 SITE REQUIREMENTS Position On Roof Minimum Clearances A On ridge or within 600mm 600mm above ridge B Elsewhere on roof 2300mm horizontally from roof surface and: a) 1000mm above highest point of fl.
17 SITE REQUIREMENTS 4. MINIMUM BUILDERS OPENING To make installation easier make the opening larger than the minimum requirements where possible. *see note † Riva 55/66/76 only If optional convection air ducts are to be used, increase the opening height by 300mm to enable connection to be made before final completion of building work.
18 SITE REQUIREMENTS 7. FIRE SURROUND CLEARANCES If the appliance is to be fitted with a fire surround, use the minimum clearances, see Diagram, between any point of the appliance and any combustible material. Stovax produce a selection of surrounds and details can be obtained from your local supplier.
19 PRE-INSTALLATION CHECKS 1. VENTILATION 1.1 This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm 2 per kW of appliance rated output above 5kW.
20 2.1 Additional ventilation is required to comply with the requirements of the Building Regulations. This must be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.
21 LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations* and standards**, along with any local regulations and working practices that may apply.
22 INSTALLATION INSTRUCTIONS 2. REMOVAL OF THE LOG GUARD 2.1 To remove the Log guard: •Lift Log Guard clear of the supporting brackets •Rotate to clear the sides of the door opening. Do not use appliance without the log guard in position.
23 INSTALLATION INSTRUCTIONS 5 •Remove the fixing screws and lift the ashpit door clear of the appliance 4.2 The replacement of the system is the reverse of the previous operations.
24 6a.4 Replace the grate in the reverse order from removal. 6a.5 The grate must sit flat on the side supports, with no debris trapped under it. Check that the centre grate sits flat and rotates freely with no debris trapped under it. 6B. FIREGRATE REMOVAL (RIVA AVANTI) (Tools required – None) 6b.
25 7.2 Replace the bricks in the reverse order from removal. 8. FITTING THE FRAME (RIVA) (3 sided ‘Profil’ frame shown) (Tools required – 2.5mm A/F Hex socket key) 8.
26 9.4 Following completion of the fitting of the ducts replace and finish the final 300mm of masonry above the front of the Riva MF. See diagram 20. HOT Final Masonry 300mm 19 8.2 The removal of the frame is the reverse of the previous operations. 8.
27 COMMISSIONING 1.1 To commission: • Replace the firebricks, baffle, and log retainer • Check the door alignment and catch operation, adjust if required, see Installation Section 6. Adjusting Door hinges • Check the soundness of door seals, castings and joints •C heck the operation of the air controls 1.
28 MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Stovax or call 01392 474011 1. ANNUAL SERVICE 1.1 At the end of the heating season strip, inspect and clean.
29 1.4 Using the appliance for the first time: • Burn at a low output for the first day of use This allows the seals, fixing glues and paint to fully cure. 1.5 During this time the appliance may give off some unpleasant odours: •Keep the room well ventilated to avoid a build-up of fumes.
30 •Squeeze a generous bead of fresh Stovax Thermic Seal glue into the rope locating groove •Press the new Stovax rope into the locati.
31 To complete this operation: •Open the main fire door to give access to the hinge block as shown in diagram 5 •Use a 3mm A/F he.
32 14. ADJUSTING ASHPAN COVER HINGES - RIVA (Tool required - 2.5mm A/F Hex socket key) Fixing Screws 7 14.1 Correct the fit of the ashpit door by loosening the hinge fixing screws and repositioning the hinges. 15. ADJUSTING ASHPAN DOOR TOUCH LATCH - RIVA (Tool required - 2.
33 BASIC SPARE PARTS LIST 1 2 6 8 7 3 4 5 Diagram No. Description Part No. 1 Door Glass GL7033 2 UpperBafe RVAC075 3 LowerBafe RVAC076 4 Centre Grate RVAC074 5 Main Grate RVAC081 6 Ashpan RVAC073 7 Ashpan Tool RVAC004 8 Log Guard RVAC072 Diagram No.
34 BASIC SPARE PARTS LIST RIVA 40 MF CASSETTE BRICKS RIVA 66 & 66 AVANTI MF CASSETTE BRICKS RIVA 76 WOOD BURNING CASSETTE BRICKS RIVA 55 MF CASSETTE BRICKS Diagram No Part No.
SERVICE RECORDS 35 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
36.
37.
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.
デバイスStovax RV66の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Stovax RV66をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはStovax RV66の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Stovax RV66の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Stovax RV66で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Stovax RV66を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はStovax RV66の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Stovax RV66に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちStovax RV66デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。