Sun MicrosystemsメーカーPCIの使用説明書/サービス説明書
ページ先へ移動 of 50
Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun™ Dual P or t 4x IB Host Channel Adapter PCI-X Installation and User’ s Guide P ar t No .
Copyright 2005 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual pr operty rights relating to technology that is described in this document. In particular , and without limitation, these intellectual property rights may include one or mor e of the U.
iii Contents Regulatory Compliance Statements xi Declaration of Conformity xv Preface xvii How This Book Is Organized xvii Using UNIX Commands xviii Shell Prompts xviii Typographic Conventions xix Rel.
iv Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 LED Displays 3 Hardware, Software, and Cable Requirements 5 2. Adapter Installation 7 IB-HCA Bus and Slot Selection 7 ▼ Installing the Adapter 7 ▼ V erifying the Installation 9 3.
Contents v Other Useful Utilities 26 cfgadm 26 snoop 27 netstat 27 kstat 27 Index 29.
vi Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
vii Figur es FIGURE 1-1 Sun Dual Port 4x IB Host Channel Adapter PCI-X Card 2 FIGURE 1-2 LED Layout 4 FIGURE 2-1 Typical Adapter-to-Switch Configuration 9 FIGURE 4-1 InfiniBand Software Stack 16 FIGUR.
viii Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
ix T ables TABLE 1-1 IB-HCA LEDs 3 TABLE 1-2 Hardware, Software, and Cable Requirements 5 TABLE B-1 SunVTS Documentation 24.
x Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
xi Regulatory Compliance Statements Y our Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital.
xii Sun Dual P or t 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 ICES-003 Class B Notice - A vis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Regulatory Compliance Statements xiii CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the pr oduct’s compliance label.
xiv Sun Dual P or t 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
xv Declaration of Conformity EMC USA—FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This equipment may not cause harmful interference. 2. This equipment must accept any interference that may cause undesir ed operation.
xvi Sun Dual P or t 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
xvii Pr eface The Sun™ Dual Port 4x IB Host Channel Adapter PCI-X Installation and User ’s Guide provides installation instructions for the Sun Dual Port 4x IB Host Channel Adapter PCI-X card. This manual includes an overview of the adapter , supported platforms, cable information, and related documentation.
xviii Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 Using UNIX Commands This document might not contain information about basic UNIX® commands and procedur es such as shutting down the system, booting the system, and configuring devices.
Preface xix T ypographic Conventions Related Documentation The following documents provide additional information regar ding the IB-HCA and related pr oducts. T ypeface 1 1 The settings on your browser might differ from these settings. Meaning Examples AaBbCc123 The names of commands, files, and directories; on-scr een computer output Edit your .
xx Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 Documentation, Support, and T raining Thir d-Party W eb Sites Sun is not responsible for the availability of third-party web sites mentioned in this document.
Preface xxi Sun W elcomes Y our Comments Sun is interested in impr oving its documentation and welcomes your comments and suggestions. Y ou can submit your comments by going to: http://www.
xxii Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
1 CHAPTER 1 Pr oduct Overview This chapter provides an overview of the Sun Dual Port 4x IB Host Channel Adapter PCI-X card and includes the following sections: ■ “Product Features” on page 1 ■.
2 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 The board characteristics ar e: ■ Power: approx. 12 watts total ■ Low prof ile PCI form-factor card (appr ox. 2.5 in. by approx. 6.7 in.) ■ Requires 4x Inf iniBand cables ■ 3.
Chapter 1 Product Overview 3 I/O Interfaces The IB-HCA includes the following interfaces: ■ T wo 4x InfiniBand copper connectors ■ PCI-X 64-bit 133 MHz edge connector InfiniBand Interface The IB-HCA provides two 4x Inf iniBand v1.1 connector (or ports) for external copper cables and is IBT A specification 1.
4 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 FIGURE 1-2 LED Layout Logical link (Amber LED) Ph ysical link (Green LED).
Chapter 1 Product Overview 5 Har dware, Softwar e, and Cable Requir ements The hardwar e, software, and cable requirements for the Sun Dual Port 4x IB Host Channel Adapter PCI-X card are listed in T ABLE 1-2 .
6 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
7 CHAPTER 2 Adapter Installation This chapter describes how to install the adapter in your system and verify that it has been installed correctly . IB-HCA Bus and Slot Selection For optimal performance, the IB-HCA card should be installed in the fastest available bus, preferably a 133 MHz PCI-X bus.
8 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 2. Remove the cover from the unit to access the card slots and connectors. 3. Select an available 3.3 V olt PCI-X or PCI slot and remove the blank front panel.
Chapter 2 Adapter Installation 9 This completes the hardwar e installation. Proceed to the verif ication instructions in “V erifying the Installation” on page 9 .
10 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 2. Check that the amber LED is illuminated for each port that is connected to the switch. If the amber LED is not on, refer to Appendix B , “Diagnostic Software and T roubleshooting” on page 23 for more information.
11 CHAPTER 3 Conf iguring IP Over Inf iniBand This chapter contains the following sections: ■ “IPoIB Configuration” on page 1 1 ■ “Managing IB Devices for IPoIB” on page 13 IPoIB Conf iguration IP Over InfiniBand (IPoIB) is automatically configur ed when the system is booted.
12 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 For example: Refer to dmesg (1M) for more information. 2. Create the Inf iniBand devices using the following command: A /dev/ibd n device is created for each IB-HCA port in the system where n is the port number .
Chapter 3 Configuring IP Over InfiniBand 13 5. V erify that the devices are plumbed. T o do this, type the command: The output includes information on the IB devices.
14 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
15 CHAPTER 4 Inf iniBand Software Overview This chapter includes the following topics: ■ “InfiniBand Software” on page 15 ■ “Related Softwar e Documentation” on page 18 Inf iniBand Software The InfiniBand softwar e is included in the Solaris 10 Operating System.
16 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 FIGURE 4-1 Inf iniBand Software Stack User Dir ect Access Pr ogramming Library This library supports service providers written according to the uDAPL 1.
Chapter 4 InfiniBand Software Ov erview 17 Inf iniBand T ransport Framework IBTF is the Solaris implementation of the InfiniBand T ransport Layer (IBTL). IBTF consists of InfiniBand Device Manager (IBDM), Inf iniBand Communications Manager (IBCM) and an InfiniBand Nexus driver .
18 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 Related Softwar e Documentation Manuals ■ System Administration Guide: Devices and Files System (.
19 APPENDIX A Inf iniBand Cable Pin Assignments FIGURE A-1 shows the InfiniBand cable connectors and pin assignments..
20 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 FIGURE A-1 Sun 4x-to-12x InfiniBand Cable Pin Assignments S1 G1 G25 S47 S2 S48 S16 G9 S2 S15 S1 G1 .
23 APPENDIX B Diagnostic Softwar e and T r oubleshooting This appendix provides an overview of the SunVTS™ diagnostic application and troubleshooting tips for checking the adapter . There is also a section outlining some common troubleshooting issues.
24 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 Using the SunVTS ibhcatest The ibhcatest diagnostic test checks the functionality of Sun Dual Port 4x IB Host Channel Adapter PCI-X card. This test can be run fr om the SunVTS user interface, or it can be run from the command line.
Appendix B Diagnostic Software and T roub leshooting 25 ▼ Using the ibhcatest 1. Ensure that the SunVTS software and the T avor driver are installed on your system. T o do this, type the following command: If a SunVTS software package is not installed, refer to the SunVTS User’ s Guide for installation instruction.
26 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 If an InfiniBand softwar e package is not installed, check your Solaris Operating System documentation for software package information. ■ Check the system log or console for T avor driver error messages.
Appendix B Diagnostic Software and T roub leshooting 27 snoop The snoop program captur es and inspects network packets. See the snoop (1M) man page for details. For example: netstat netstat shows network status. See the netstat (1M) man page for details.
28 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005.
29 Index A adapter description, 1 features, 1 installation, 7 layout, 2 C cable requir ements, 5 cables connectors, 19 part numbers, 5 pin assignments, 19 D diagnostics, ibhcatest, 24 documentation ma.
30 Sun Dual P or t 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005 versions, 5 T T avor driver, 17 troubleshooting IB-HCA, 25 tasks, 25 utilities, 26 U uDAPL, 15, 1.
デバイスSun Microsystems PCIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sun Microsystems PCIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSun Microsystems PCIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sun Microsystems PCIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sun Microsystems PCIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sun Microsystems PCIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSun Microsystems PCIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sun Microsystems PCIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSun Microsystems PCIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。