D200-24-00 1 I56-0056-0 7R DH100ACDCL WP W ater tight Air Duct Smoke Detector with Extended Air Speed Range INST ALLA TION AND MAINTENANCE INSTRUCTIONS 3825 Ohio A v enue, St. Charles , Illinois 60 174 800/736-7672, F AX: 630-377-6495 www .s ystemsensor .
This device will not sense smok e unless the ventilation s ys- tem is operating and the co ver is installed. F or this detector to function pr operly , it MUST be installed according to the instructions in this manual. F urthermore , the detector MUST be operated within ALL electrical and environmental specifications listed in this manual.
e xhaust tube is molded onto the base of the duct housing, and the A2440-00 Exhaust T ube Extension is available as an accessory in those cases where the molded e xhaust port does not extend at least 2 inches into the duct. The sampling tube is alwa ys installed with the air inlet holes facing into the air flow .
NO TE: An alternate method to using the ST -1 0 is to use two ST -5 sampling tubes. R emo ve the flange from one of the tubes and install as described abov e . After the installation, use electrical tape to close off some of the sampling holes so that there ar e a total of 1 0 to 12 holes spaced as evenly as possible across the width of the duct.
Before conducting these tests , notify the proper authorities that the smoke detection s ystem will be tempor arily out of service . Disable the zone or sy stem under test to prev ent unw anted alarms. [6.1] Smoke Entr y T ests [6.1.1] Air Flow The DH1 00A CDCL WP is designed to operate o ver an e xtended air speed r ange of 1 00 to 4000 FPM.
15 19 14 3 20 1 3 2 Alarm Signal Aux. Power + Sup. N. O. Sup. COM Aux. Power – NOTE: Wiring diagram shown is for DH100ACDCLWP 4-wire duct smoke detector system equipped without a control panel. Alarm (Red LED) Power (Green LED) Common APA451 DH100ACDCLWP D200-24-00 6 I56-0056-0 7R Do not loop wire under terminals when wiring detector s.
detector board to cause a tr ouble condition locally and at the sy stem control panel. Cov er T amper — If the cov er is remo ved or not properly secur ed for a period longer than 7 minutes, a tr ouble signal is generated to indicate the co ver is missing.
D200-24-00 8 I56-0056-0 7R Three-Y ear Limited Warranty Sy stem Sensor warrants its enclosed air duct smok e detector to be free from defects in materials and workmanship under normal use and service for a period of three y ears fr om date of manufacture .
デバイスSystem Sensor INNOVAIR DH100ACDCLWPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
System Sensor INNOVAIR DH100ACDCLWPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSystem Sensor INNOVAIR DH100ACDCLWPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。System Sensor INNOVAIR DH100ACDCLWPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。System Sensor INNOVAIR DH100ACDCLWPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
System Sensor INNOVAIR DH100ACDCLWPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSystem Sensor INNOVAIR DH100ACDCLWPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、System Sensor INNOVAIR DH100ACDCLWPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSystem Sensor INNOVAIR DH100ACDCLWPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。